Control Of An Extracorporeal Heart Assist Device

被引:0
|
作者
Sievert, Alexander [1 ]
Wiesener, Constantin [2 ]
Arndt, Andreas [2 ]
Drewelow, Wolfgang [1 ]
Simanski, Olaf [3 ]
机构
[1] Univ Rostock, Inst Automat, D-18119 Rostock, Germany
[2] Berlin Heart GmbH, D-12247 Berlin, Germany
[3] Hsch Wismar, Univ Appl Sci & Technol, Business & Design, D-23952 Wismar, Germany
关键词
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Heart assist devices provide mechanical circulatory support for patients with end-stage heart failure. Extracorporeal blood pumps are applied to adult and pediatric patients in the case of uni- and biventricular assistance. Modern driving units provide more mobility what is an immense benefit to the quality of life of the patients. The treated heart assist device in this article is the EXCOR system (Berlin Heart GmbH, Germany), which is a pneumatically driven extracorporeal assist device. It allows uni-and biventricular heart support. The automatic control system should match the pump output to the metabolic needs by controlling the piston movement and the enclosed air mass in the pneumatic system. This paper describes the design of a control system for the extracorporeal assist device. A developed model is used for controller synthesis. This model is based on modified basic physical equations and optimized for practical applications.
引用
收藏
页码:63 / 68
页数:6
相关论文
共 50 条
  • [31] Extracorporeal membrane oxygenation (ECMO) as cardiac assist device in pediatrics
    Kammerer, T
    Fuchs, A
    Mendonca, M
    Däbritz, SH
    Kozlik-Feldmann, R
    ANASTHESIOLOGIE INTENSIVMEDIZIN NOTFALLMEDIZIN SCHMERZTHERAPIE, 2003, 38 (08): : 514 - 521
  • [32] EXTRACORPOREAL LIVER ASSIST DEVICE (ELAD) - A PRELIMINARY-REPORT
    WOOD, RP
    KATZ, SM
    OZAKI, CF
    MONSOUR, HP
    GISLASON, GT
    KELLY, JH
    SUSSMAN, NL
    TRANSPLANTATION PROCEEDINGS, 1993, 25 (04) : 53 - 54
  • [33] Bridge to recovery or transplantation:: pulsatile, pneumatic, extracorporeal ventricular assist device (EXCOR-Berlin Heart®) application
    Pektok, E.
    Cikirikcioglu, M.
    Djebaili, K. M.
    Sierra, J.
    Kalangos, A.
    BRITISH JOURNAL OF SURGERY, 2006, 93 (09) : 1166 - 1166
  • [34] Control of heart assist devices
    Antaki, JF
    Boston, JR
    Simaan, MA
    42ND IEEE CONFERENCE ON DECISION AND CONTROL, VOLS 1-6, PROCEEDINGS, 2003, : 4084 - 4089
  • [35] Left ventricular assist device in heart failure
    Ashraf, O
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2006, 131 (05): : 1211 - 1212
  • [36] Ventricular assist device in univentricular heart physiology
    Brancaccio, Gianluca
    Gandolfo, Fabrizio
    Carotti, Adriano
    Amodeo, Antonio
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2013, 16 (04) : 568 - 569
  • [37] Midwest trials of heart-assist device
    Mitka, M
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2001, 286 (21): : 2661 - 2661
  • [38] Ventricular assist device: saving the failing heart
    Kurien, Sudha
    Gallagher, Colleen
    PROGRESS IN TRANSPLANTATION, 2010, 20 (02) : 134 - 141
  • [39] ARTIFICIAL-HEART - VENTRICULAR ASSIST DEVICE
    SEZAI, Y
    HASEGAWA, T
    MIYAMOTO, A
    KITAMURA, S
    UMEDA, S
    KAWANO, K
    SHINDOU, S
    RIKUKAWA, H
    SHIONO, M
    OGASAWARA, K
    ORIME, Y
    ATSUMI, K
    FUJIMASA, I
    IMACHI, K
    ARTIFICIAL ORGANS, 1988, 12 (05) : 461 - 461
  • [40] BIVENTRICULAR ASSIST DEVICE: A FIX FOR THE FAILING HEART
    Pawa, Arpita
    Savani, Saloni
    Santosh, Natasha
    Pawa, Akhil
    Virani, Ahmed
    CHEST, 2024, 166 (04) : 790A - 791A