Strain gauges used in the mechanical testing of bones Part II: "In vitro" and "in vivo" technique

被引:0
|
作者
Cordey, J [1 ]
Gautier, E [1 ]
机构
[1] ASIF, Res Inst, AO, CH-7270 Davos, Switzerland
关键词
strain gauge; preparation; axial load; bending; torque; stress protection;
D O I
暂无
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
How to choose and prepare the strain gauges for bonding on bones "in vitro" and "in vivo"? This communication aims to elucidate technical details and some applications: direct assessment of the axial load, the bending moment, and the torque applied to long bones by the physiological loads. As a typical example of application, we will show the assessment of stress protection due to plates on the bones in the sheep tibia.
引用
收藏
页码:S14 / S20
页数:7
相关论文
共 50 条
  • [31] Observation of cavitation pits on mechanical heart valve surfaces in an artificial heart used in in vitro testing
    Hwansung Lee
    Akihiko Homma
    Eisuke Tatsumi
    Yoshiyuki Taenaka
    Journal of Artificial Organs, 2010, 13 : 17 - 23
  • [33] Numerical validation of the shear compression specimen. Part II: Dynamic large strain testing
    Dorogoy, A.
    Rittel, D.
    Experimental Mechanics, 2005, 45 (02) : 178 - 185
  • [34] Joining techniques for aluminium spaceframes used in automobiles Part II - adhesive bonding and mechanical fasteners
    Barnes, TA
    Pashby, IR
    JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2000, 99 (1-3) : 72 - 79
  • [35] Deep Bleeder Acoustic Coagulation (DBAC)-part II: in vivo testing of a research prototype system
    Sekins, K. Michael
    Barnes, Stephen R.
    Fan, Liexiang
    Hopple, Jerry D.
    Hsu, Stephen J.
    Kook, John
    Lee, Chi-Yin
    Maleke, Caroline
    Zeng, Xiaozheng
    Moreau-Gobard, Romain
    Ahiekpor-Dravi, Alexis
    Funka-Lea, Gareth
    Eaton, John
    Wong, Keith
    Keneman, Scott
    Mitchell, Stuart B.
    Dunmire, Barbrina
    Kucewicz, John C.
    Clubb, Fred J.
    Miller, Matthew W.
    Crum, Lawrence A.
    JOURNAL OF THERAPEUTIC ULTRASOUND, 2015, 3
  • [36] Percutaneous fiber-optic biosensor for immediate evaluation of chemotherapy efficacy in vivo (Part II): In vitro and in vivo characterization
    Fan, Shu-Yu
    Chiu, Han-Sheng
    Lin, Ding-Yi
    Liao, Alexandra
    Liao, Kuo-Chih
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 222 : 579 - 587
  • [37] Genetic strain variations in the metaphase-II phenotype of mouse oocytes matured in vivo or in vitro
    Ibáñez, E
    Sanfins, A
    Combelles, CMH
    Overström, EW
    Albertini, DF
    REPRODUCTION, 2005, 130 (06) : 845 - 855
  • [38] Poloxamer 407 microspheres for orotransmucosal drug delivery. Part II: In vitro/in vivo evaluation
    Monti, D.
    Burgalassi, S.
    Rossato, M. S.
    Albertini, B.
    Passerini, N.
    Rodriguez, L.
    Chetoni, P.
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2010, 400 (1-2) : 32 - 36
  • [39] Implants in bone: Part II. Research on implant osseointegration: Material testing, mechanical testing, imaging and histoanalytical methods
    von Wilmowsky C.
    Moest T.
    Nkenke E.
    Stelzle F.
    Schlegel K.A.
    Oral and Maxillofacial Surgery, 2014, 18 (4) : 355 - 372
  • [40] Testing and calibrating the mechanical-type toggle torque wrenches used in implant dentistry: A dental technique
    Wadhwani, Chandur P. K.
    O'Brien, Richard
    Rosen, Paul S.
    Chung, Kwok-Hung
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (03): : 403 - 407