Outcomes Following Implantation of Two Second-Generation Trabecular Micro-Bypass Stents in Patients with Open-Angle Glaucoma on One Medication: 18-Month Follow-Up

被引:44
|
作者
Lindstrom, Richard [1 ]
Lewis, Richard [2 ]
Hornbeak, Dana M. [3 ]
Voskanyan, Lilit [4 ]
Giamporcaro, Jane Ellen [3 ]
Hovanesian, John [5 ]
Sarkisian, Steven [6 ]
机构
[1] Minnesota Eye Consultants, Minneapolis, MN 55404 USA
[2] Sacramento Eye Consultants, Sacramento, CA USA
[3] Glaukos Corp, San Clemente, CA USA
[4] SV Malayan Ophthalmol Ctr, Yerevan, Armenia
[5] Harvard Eye Associates, Laguna Hills, CA USA
[6] Univ Oklahoma, Hlth Sci Ctr, Dean A McGee Eye Inst, Oklahoma City, OK USA
关键词
Glaucoma; IOP; Medication; MIGS; Ophthalmology; Trabecular micro-bypass; OCULAR HYPERTENSION; MICROBYPASS STENTS; CATARACT; PHACOEMULSIFICATION; ISTENT; TRIAL; ADHERENCE; SURGERY; SAFETY; INJECT;
D O I
10.1007/s12325-016-0420-8
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The study objective was to evaluate the intraocular pressure (IOP) and medication-lowering effect of 2 second-generation trabecular micro-bypass stents in eyes with open-angle glaucoma (OAG) on one preoperative medication. Fifty-seven qualified phakic eyes with OAG on 1 medication, preoperative medicated IOP of 18-30 mmHg, and preoperative unmedicated (post-washout) IOP of 22-38 mmHg underwent implantation of 2 second-generation trabecular micro-bypass stents in a standalone procedure. Evaluations included IOP, best-corrected visual acuity, medication use, fundus and slit lamp examinations, visual field, cup to disc ratio, pachymetry, and complications and interventions. Subjects have been followed for 18 months, and follow-up is ongoing. At Month 12 postoperative, 100% of eyes had achieved an IOP reduction aeyen20% (100% had IOP aecurrency sign18 mmHg and 67% had IOP aecurrency sign15 mmHg) without medication versus preoperative unmedicated IOP, and 75% had IOP reduction aeyen20% without medication versus preoperative medicated IOP. The Month 12 mean unmedicated IOP had decreased by 42%, to 14.2 +/- 1.9 mmHg vs 24.4 +/- 1.3 mmHg preoperatively, and this reduction was maintained through 18 months (14.4 +/- 2.1 mmHg). A high safety profile was observed. In this prospective, open-label, single-arm study, the standalone implantation of two second-generation trabecular micro-bypass stents in OAG patients on 1 preoperative medication resulted in IOP reduction to aecurrency sign15 mmHg and elimination of medication through 18 months, with favorable safety. ClinicalTrials.gov identifier, NCT02868190. Glaukos Corporation, San Clemente, CA.
引用
收藏
页码:2082 / 2090
页数:9
相关论文
共 48 条
  • [31] Cost-utility analysis of trabecular micro-bypass stents (TBS) in patients with mild-to-moderate open-angle Glaucoma in Italy
    Antonio Maria Fea
    Francesco Cattel
    Stefano Gandolfi
    Giorgio Buseghin
    Gianluca Furneri
    Ciro Costagliola
    BMC Health Services Research, 21
  • [32] Prospective, randomized study of one, two, or three trabecular bypass stents in open-angle glaucoma subjects on topical hypotensive medication
    Katz, L. Jay
    Erb, Carl
    Carceller Guillamet, Amadeu
    Fea, Antonio M.
    Voskanyan, Lilit
    Wells, Jeffrey M.
    Giamporcaro, Jane Ellen
    CLINICAL OPHTHALMOLOGY, 2015, 9 : 2313 - 2320
  • [33] Safety and Efficacy of Two Trabecular Micro-Bypass Stents as the Sole Procedure in Japanese Patients with Medically Uncontrolled Primary Open-Angle Glaucoma: A Pilot Case Series
    Shiba, Daisuke
    Hosoda, Shingo
    Yaguchi, Saori
    Ozeki, Naoki
    Yuki, Kenya
    Tsubota, Kazuo
    JOURNAL OF OPHTHALMOLOGY, 2017, 2017
  • [34] Prospective, Non-randomized, 36-Month Study of Second-Generation Trabecular Micro-Bypass Stents with Phacoemulsification in Eyes with Various Types of Glaucoma
    Hengerer, Fritz H.
    Auffarth, Gerd U.
    Riffel, Christoffer
    Conrad-Hengerer, Ina
    OPHTHALMOLOGY AND THERAPY, 2018, 7 (02) : 405 - 415
  • [35] Prospective, Non-randomized, 36-Month Study of Second-Generation Trabecular Micro-Bypass Stents with Phacoemulsification in Eyes with Various Types of Glaucoma
    Fritz H. Hengerer
    Gerd U. Auffarth
    Christoffer Riffel
    Ina Conrad-Hengerer
    Ophthalmology and Therapy, 2018, 7 : 405 - 415
  • [36] Critique of the Study, "Five-year Outcomes Prospective Study of Two First-Generation Trabecular Micro-Bypass Stents (Istent®) in Open-Angle Glaucoma" by Hady Saheb Et Al
    Mercer, Rachel
    Alaghband, Pouya
    CURRENT EYE RESEARCH, 2021, 46 (07) : 1073 - 1074
  • [37] Cost-comparison of two trabecular micro-bypass stents versus selective laser trabeculoplasty or medications only for intraocular pressure control for patients with open-angle glaucoma
    Berdahl, John P.
    Khatana, Anup K.
    Katz, L. Jay
    Herndon, Leon
    Layton, Andrew J.
    Yu, Tiffany M.
    Bauer, Matthew J.
    Cantor, Louis B.
    JOURNAL OF MEDICAL ECONOMICS, 2017, 20 (07) : 760 - 766
  • [38] COST-COMPARISON OF TWO TRABECULAR MICRO-BYPASS STENTS VERSUS SELECTIVE LASER TRABECULOPLASTY OR MEDICATIONS ONLY FOR INTRAOCULAR PRESSURE CONTROL FOR PATIENTS WITH OPEN-ANGLE GLAUCOMA
    Berdahl, J. P.
    Khatana, A. K.
    Katz, L. J.
    Herndon, L.
    Layton, A. J.
    Yu, T. M.
    Bauer, M. J.
    Cantor, L. B.
    VALUE IN HEALTH, 2016, 19 (03) : A301 - A301
  • [39] A CANADIAN COST-UTILITY ANALYSIS OF TWO TRABECULAR MICRO-BYPASS STENTS IMPLANTED AT TIME OF CATARACT SURGERY IN PATIENTS WITH MILD-TO-MODERATE OPEN-ANGLE GLAUCOMA
    Ahmed, I
    Goeree, R.
    Patel, V
    Murray, J.
    Falvey, H.
    Podbielski, D. W.
    VALUE IN HEALTH, 2018, 21 : S261 - S261
  • [40] Outcomes of XEN 63 Device at 18-Month Follow-Up in Glaucoma Patients: A Two-Center Retrospective Study
    Fea, Antonio Maria
    Menchini, Martina
    Rossi, Alessandro
    Posarelli, Chiara
    Malinverni, Lorenza
    Figus, Michele
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (13)