VOLUME CT DOSE INDEX AND DOSE-LENGTH PRODUCT VALUES ACCORDING TO FACILITY SIZE IN JAPAN

被引:6
|
作者
Matsunaga, Yuta [1 ,2 ]
Kondo, Yuya [3 ]
Kobayashi, Kenichi [4 ]
Kobayashi, Masanao [5 ]
Minami, Kazuyuki [5 ]
Suzuki, Shoichi [5 ]
Chida, Koichi [2 ]
Asada, Yasuki [5 ]
机构
[1] Nagoya Kyoritsu Hosp, Dept Imaging, Nakagawa Ku, 1-172 Hokke, Nagoya, Aichi, Japan
[2] Tohoku Univ, Grad Sch Med, Fac Hlth Sci, Dept Radiol Technol,Aoba Ku, 2-1 Seiryo Machi, Sendai, Miyagi, Japan
[3] Handa City Hosp, Dept Radiol Technol, 2-29 Toyo Cho, Handa, Aichi, Japan
[4] Fujita Hlth Univ Hosp, Dept Radiol, 1-98 Dengakugakubo,Kutsukake Cho, Toyoake, Aichi, Japan
[5] Fujita Hlth Univ, Sch Hlth Sci, Fac Radiol Technol, 1-98 Dengakugakubo,Kutsukake Cho, Toyoake, Aichi, Japan
基金
日本学术振兴会;
关键词
D O I
10.1093/rpd/ncz284
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The aim of this study was to investigate differences in volume computed tomography dose index (CTDIvol) and dose-length product (DLP) values according to facility size in Japan. A questionnaire survey was sent to 3000 facilities throughout Japan. Data from each facility were collected including bed number, computed tomography (CT) scan parameters employed and the CTDIvol and/or DLP values displayed on the CT scanner during each examination. The CTDIvol and DLP for 11 adult and 6 paediatric CT examinations were surveyed. Comparison of CTDIvol and DLP values of each examination according to facility size revealed key differences in CT dose between small and large facilities. This study highlights the importance of lowering the dose of coronary artery examination with contrast agent in smaller facilities and of lowering the dose of adult and paediatric head CT without contrast agent in larger facilities. The results of this study are valid in Japan.
引用
收藏
页码:261 / 269
页数:9
相关论文
共 50 条
  • [21] Cardiac-Specific Conversion Factors to Estimate Radiation Effective Dose From Dose-Length Product in Computed Tomography
    Trattner, Sigal
    Halliburton, Sandra
    Thompson, Carla M.
    Xu, Yanping
    Chelliah, Anjali
    Jambawalikar, Sachin R.
    Peng, Boyu
    Peters, M. Robert
    Jacobs, Jill E.
    Ghesani, Munir
    Jang, James J.
    Al-Khalidi, Hussein
    Einstein, Andrew J.
    JACC-CARDIOVASCULAR IMAGING, 2018, 11 (01) : 64 - 74
  • [22] Estimating Effective Dose of Radiation From Pediatric Cardiac CT Angiography Using a 64-MDCT Scanner: New Conversion Factors Relating Dose-Length Product to Effective Dose
    Trattner, Sigal
    Chelliah, Anjali
    Prinsen, Peter
    Ruzal-Shapiro, Carrie B.
    Xu, Yanping
    Jambawalikar, Sachin
    Amurao, Maxwell
    Einstein, Andrew J.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 208 (03) : 585 - 594
  • [23] Validity of the size-specific dose estimate in adults undergoing coronary CT angiography: comparison with the volume CT dose index
    Kidoh, Masafumi
    Utsunomiya, Daisuke
    Oda, Seitaro
    Funama, Yoshinori
    Yuki, Hideaki
    Nakaura, Takeshi
    Kai, Noriyuki
    Nozaki, Takeshi
    Yamashita, Yasuyuki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2015, 31 : 205 - 211
  • [24] Validity of the size-specific dose estimate in adults undergoing coronary CT angiography: comparison with the volume CT dose index
    Masafumi Kidoh
    Daisuke Utsunomiya
    Seitaro Oda
    Yoshinori Funama
    Hideaki Yuki
    Takeshi Nakaura
    Noriyuki Kai
    Takeshi Nozaki
    Yasuyuki Yamashita
    The International Journal of Cardiovascular Imaging, 2015, 31 : 205 - 211
  • [25] TOWARD NATIONAL CT DIAGNOSTIC REFERENCE LEVELS IN THE UNITED ARAB EMIRATES: A MULTICENTER REVIEW OF CT DOSE INDEX AND DOSE LENGTH PRODUCT
    Abuzaid, Mohamed M.
    Elshami, Wiam
    El Serafi, A.
    Hussien, T.
    McConnell, J. R.
    Tekin, H. O.
    RADIATION PROTECTION DOSIMETRY, 2020, 190 (03) : 243 - 249
  • [26] Computed tomography dose index and dose length product for cone-beam CT: Monte Carlo simulations of a commercial system
    Kim, Sangroh
    Song, Haijun
    Samei, Ehsan
    Yin, Fang-Fang
    Yoshizumi, Terry T.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2011, 12 (02): : 84 - 95
  • [27] Patient-specific Effective Dose Estimation from Dose-Length Product in Lung Computed Tomography Using Monte Carlo Simulation
    Fallahmohammadi, Gholamreza
    Nodeh, Zeinab Kordzini
    Mahdavi, Mohammad
    JOURNAL OF MEDICAL SIGNALS & SENSORS, 2024, 14 (04):
  • [28] Estimating Effective Dose for CT Using Dose-Length Product Compared With Using Organ Doses: Consequences of Adopting International Commission on Radiological Protection Publication 103 or Dual-Energy Scanning
    Christner, Jodie A.
    Kofler, James M.
    McCollough, Cynthia H.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (04) : 881 - 889
  • [29] Conversion from dose length product to effective dose for the CT component of whole-body PET/CT
    Inoue, Yusuke
    Ohkubo, Yu
    Nagahara, Kazunori
    Uehara, Ayuka
    Takano, Makoto
    ANNALS OF NUCLEAR MEDICINE, 2022, 36 (04) : 411 - 419
  • [30] Conversion from dose length product to effective dose for the CT component of whole-body PET/CT
    Yusuke Inoue
    Yu Ohkubo
    Kazunori Nagahara
    Ayuka Uehara
    Makoto Takano
    Annals of Nuclear Medicine, 2022, 36 : 411 - 419