Quality assurance evaluation of spot scanning beam proton therapy with an anthropomorphic prostate phantom

被引:12
|
作者
Iqbal, K. [1 ,2 ,3 ]
Gillin, M. [1 ]
Summers, P. A. [1 ,4 ]
Dhanesar, S. [1 ]
Gifford, K. A. [1 ]
Buzdar, S. A. [2 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[2] Islamia Univ Bahawalpur, Dept Phys, Bahawalpur, Pakistan
[3] Shaukat Khanum Canc Hosp & Res Ctr, Dept Radiat Oncol, Lahore, Pakistan
[4] Univ Texas MD Anderson Canc Ctr, Radiol Phys Ctr, Houston, TX 77030 USA
来源
BRITISH JOURNAL OF RADIOLOGY | 2013年 / 86卷 / 1031期
关键词
RADIOTHERAPY; SYSTEM;
D O I
10.1259/bjr.20130390
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The purpose of this study was to evaluate spot scanning proton therapy with an anthropomorphic prostate phantom at the Proton Therapy Center of The University of Texas MD Anderson Cancer Center at Houston, TX (PTCH). Methods: An anthropomorphic prostate phantom from the Radiological Physics Center (RPC), The University of Texas MD Anderson Cancer Center, Houston, TX, was used, which contained thermoluminescent dosemeters and GAFCHROMIC (R) EBT2 film (ISP Technologies, Wayne, NJ). The phantom was irradiated by the Hitachi synchrotron (Hitachi America, Ltd, Tarrytown, NY), and the results were compared between the treatment planning system (TPS) and RPC measurements. Results: RPC results show that the right/left, inferior/superior and posterior/anterior aspects of the coronal/sagittal and EBT2 film measurements were within 67%/64mm of the TPS. The RPC thermoluminescent dosemeter measurements of the prostate and femoral heads were within 3% of the TPS. Conclusion: The RPC prostate phantom is a useful mechanism to evaluate spot scanning beam proton therapy within certain confidence levels. Advances in knowledge: The RPC anthropomorphic prostate phantom could be used to establish quality assurance of spot scanning proton beam for patients with prostate cancer.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] ADAM a Breathing Anthropomorphic Phantom for Quality Assurance of Respiratory Motion-Management Techniques in Radiation Therapy
    Pallotta, S.
    Calusi, S.
    Foggi, L.
    Lisci, R.
    Marrazzo, L.
    Masi, L.
    Talamonti, C.
    Livi, L.
    Simontacchi, G.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 3223 - 3224
  • [42] Comprehensive Quality Assurance Procedures for Uniform Scanning Proton Therapy Machines
    Zheng, Y.
    Ding, X.
    Mascia, A.
    Hsi, W.
    Kang, Y.
    Ramirez, E.
    Zeidan, O.
    Schreuder, N.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3749 - 3749
  • [43] Patient specific dosimetry and quality assurance for an active uniform scanning proton beam
    Mascia, A. E.
    Wolanski, M.
    Jesseph, R.
    Nichiporov, D.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S652 - S652
  • [44] Use of a novel two-dimensional ionization chamber array for pencil beam scanning proton therapy beam quality assurance
    Lin, Liyong
    Kang, Minglei
    Solberg, Timothy D.
    Mertens, Thierry
    Baumer, Christian
    Ainsley, Christopher G.
    McDonough, James E.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (03): : 270 - 276
  • [45] Validation of Low-Dose-Tail Modeling for Proton Pencil Beam Spot Scanning Using a Quality Assurance Test Pattern
    Lin, L.
    Huang, S.
    Kang, M.
    Solberg, T.
    McDonough, J.
    Ainsley, C.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3208 - 3209
  • [46] Design, Development, and Evaluation of a Modified, Anthropomorphic, Head and Neck, Quality Assurance Phantom for Use in Stereotactic Radiosurgery
    Faught, A.
    Kry, S.
    Luo, D.
    Molineu, A.
    Galvin, J.
    Drzymala, R.
    Timmerman, R.
    Sheehan, J.
    Gillin, M.
    Ibbott, G.
    Followill, D.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [47] Design and implementation of an anthropomorphic quality assurance phantom for intensity-modulated radiation therapy for the radiation therapy oncology group
    Molineu, A
    Followill, DS
    Balter, PA
    Hanson, WF
    Gillin, MT
    Huq, MS
    Eisbruch, A
    Ibbott, GS
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : 577 - 583
  • [48] Application of cone-shaped scintillation detector for quality assurance in pencil beam scanning proton therapy systems
    Lingjing, Pan
    Xianbao, Gu
    Yuanyuan, Wang
    Yangfan, Zhang
    Xiaoming, Lu
    Zhipeng, Liu
    [J]. He Jishu/Nuclear Techniques, 2024, 47 (08):
  • [49] Testing Different Materials for a Quality Assurance Phantom for Proton Radiography Using the MEVION Proton Therapy System
    Pelas, C.
    Alsbou, N.
    Ahmad, S.
    Ali, I.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [50] Spot scanning proton therapy for craniopharyngioma
    Amsbaugh, Mark J.
    Zhu, X. Ronald
    Palmer, Matthew
    Poenisch, Falk
    McAleer, Mary F.
    Mahajan, Anita
    Grosshans, David R.
    [J]. PRACTICAL RADIATION ONCOLOGY, 2012, 2 (04) : 314 - 318