Identification of a New Metabolite of GHB: Gamma-Hydroxybutyric Acid Glucuronide

被引:42
|
作者
Petersen, Ida Nymann [1 ]
Tortzen, Christian [1 ]
Kristensen, Jesper Langgaard [1 ]
Pedersen, Daniel Sejer [1 ]
Breindahl, Torben [2 ]
机构
[1] Univ Copenhagen, Dept Drug Design & Pharmacol, Fac Hlth & Med Sci, Copenhagen, Denmark
[2] Vendsyssel Hosp, Dept Clin Biochem, Hjorring, Denmark
关键词
CHROMATOGRAPHY-MASS-SPECTROMETRY; ETHYL GLUCURONIDE; URINARY CONCENTRATIONS; IN-VITRO; STABILITY; HUMANS; BLOOD; SERUM; HAIR;
D O I
10.1093/jat/bkt027
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Gamma-hydroxybutyric acid (GHB) is an important analyte in clinical and forensic toxicology with a narrow detection window of 36 h. In the search of improved detection methods, the existence in vivo of a glucuronated GHB metabolite (GHB-GLUC) was hypothesized. Chemically pure standards of GHB-GLUC and a deuterated analogue for chromatography were synthesized. Liquid chromatography and tandem mass spectrometry were used for targeted analysis in anonymous clinical urine samples (n 50). GHB-GLUC was found in concentrations ranging from 0.11 to 5.0 g/mL (mean: 1.3 1.2 g/mL). Thus far, this is the first report of a GHB glucuronide detected in biological samples. Given that glucuronides generally have longer half-life values than their corresponding free drugs, GHB-GLUC should theoretically be a biomarker of GHB intoxication. It is also proposed that the hitherto unexplained reports of elevated GHB concentrations in some biological samples, which has caused the setting of a relatively high cutoff value (10 g/mL), represent total GHB measurements (sum of free GHB and actively chemically hydrolyzed GHB-GLUC). To address these challenges, the present study must be followed by comprehensive pharmacokinetic and stability studies after the controlled administration of GHB.
引用
收藏
页码:291 / 297
页数:7
相关论文
共 50 条