PURPOSE. We estimated coefficients of repeatability for Spectralis optical coherence tomography (OCT)-derived automated retinal thickness and volume measurements in subjects with center-involving diabetic macular edema (DME). METHODS. A total of 50 eyes of 50 consecutive patients with center-involving DME underwent four consecutive "fast" volume scans at a single session using one OCT device operated by one of two experienced operators. Bland-Altman coefficients of repeatability (CR) were calculated for automated retinal thickness measurements in the nine Early Treatment of Diabetic Retinopathy Study (ETDRS) subfields, center point thickness, and total macular volume. Scans were evaluated for significant automated retinal boundary detection error and revised estimates for CR calculated with these scans excluded. RESULTS. CR in the central subfield was 8.03 mu m (95% confidence interval [CI] 7.70-8.35 mu m). In other subfields, CR ranged from 6.54 to 18.25 mu m. Scan sets from 13 subjects had significant boundary detection error; reanalysis with these excluded yielded a CR for the central subfield of 7.44 mu m with CR for all other subfields <8 mu m. CONCLUSIONS. Retinal thickness measurements in subjects with DME obtained using Spectralis OCT are considerably less variable than has been reported with other devices. Changes in central subfield thickness >8 mu m can be considered more indicative of true clinical change rather than measurement variability. This finding informs clinical practice and clinical trial design. (Invest Ophthalmol Vis Sci. 2012;53:7754-7759) DOI:10.1167/iovs.12-10895
引用
收藏
页码:7754 / 7759
页数:6
相关论文
共 50 条
  • [1] Repeatability of Macular Thickness Measurements in Patients With Diabetic Macular Edema
    Invernizzi, A.
    Pellegrini, M.
    Cigada, M.
    Peroglio, A.
    Bassani, N.
    Staurenghi, G.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [2] Effect of OCT volume scan density on thickness measurements in diabetic macular edema
    M G Nittala
    R Konduru
    H Ruiz-Garcia
    S R Sadda
    [J]. Eye, 2011, 25 : 1347 - 1355
  • [3] Effect of OCT volume scan density on thickness measurements in diabetic macular edema
    Nittala, M. G.
    Konduru, R.
    Ruiz-Garcia, H.
    Sadda, S. R.
    [J]. EYE, 2011, 25 (10) : 1347 - 1355
  • [4] Yearly Loss of Retinal Thickness and Macular Volume Estimated from SPECTRALIS OCT Measurements in Patients with Stargardt Macular Dystrophy
    Strauss, Rupert
    Fletcher, Emily
    Wolfson, Yulia
    Scholl, Hendrik
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [5] Variables Affecting Short- and Long Term Repeatability of Macular Thickness Measurements Using Heidelberg Spectralis OCT
    Lid, J.
    Morisbakk, T. L.
    Lundmark, P. O.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [6] Disparity between foveal thickness and macular volume in diabetic macular edema
    Lima-Gomez, Virgilio
    Razo Blanco-Hernandez, Dulce Milagros
    [J]. CIRUGIA Y CIRUJANOS, 2012, 80 (01): : 24 - 29
  • [7] Repeatability and reproducibility of macular thickness measurements with the Humphrey OCT system
    Muscat, S
    Parks, S
    Kemp, E
    Keating, D
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 (02) : 490 - 495
  • [8] Intersession repeatability of macular thickness measurements with the Humphrey 2000 OCT
    Koozekanani, D
    Roberts, C
    Katz, SE
    Herderick, EE
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (06) : 1486 - 1491
  • [9] Repeatability of Retinal Macular Thickness Measurements in Healthy Subjects and Diabetic Patients with Clinically Significant Macular Edema: Evaluation of the Follow-Up System of Spectralis Optical Coherence Tomography
    Fiore, Tito
    Lupidi, Marco
    Androudi, Sofia
    Giansanti, Fabrizio
    Fruttini, Daniela
    Cagini, Carlo
    [J]. OPHTHALMOLOGICA, 2015, 233 (3-4) : 186 - 191
  • [10] Repeatability of choroidal thickness measurements with Spectralis OCT images
    Lau, Jason K.
    Cheung, Sin Wan
    Collins, Michael J.
    Cho, Pauline
    [J]. BMJ OPEN OPHTHALMOLOGY, 2019, 4 (01):