Soil Gas Sampling for 1,4-Dioxane during Heated Soil Vapor Extraction

被引:0
|
作者
Burris, David R. [1 ]
Dahlen, Paul R. [2 ]
Hinchee, Robert E. [3 ]
机构
[1] Integrated Sci & Technol Inc, 228 Harrison Ave,Suite 102, Panama City, FL 32401 USA
[2] Arizona State Univ, Dept Sustainable Engn & Built Environm, POB 873005, Tempe, AZ 85287 USA
[3] Integrated Sci & Technol Inc, POB 215, Brigham City, UT 84302 USA
来源
关键词
D O I
10.1111/gwmr.12255
中图分类号
TV21 [水资源调查与水利规划];
学科分类号
081501 ;
摘要
Soil gas sampling for 1,4-dioxane at elevated soil temperatures, such as those experienced during in-situ thermal treatment, has the potential to yield low results due to condensation of water vapor in the ambient temperature sampling vessel and the partitioning of 1,4-dioxane into that condensate. A simple vapor/condensate sampling apparatus was developed to collect both condensate and vapor samples to allow for determination of a reconstituted effective soil gas concentration for 1,4-dioxane. Results using the vapor/condensate sampling apparatus during a heated air injection SVE field demonstration are presented, along with those of a comparable laboratory system. Substantial 1,4-dioxane mass was found in the condensate in both the lab and field (as high as similar to 50% in field). As soil temperatures increased, less 1,4-dioxane mass was detected in field condensate samples than expected based on laboratory experiments. Extraction well effluent sampling at the wellhead by direct vapor canister sampling provided erratic results (several biased low by a factor of 5 or more) compared to those of the vapor/condensate apparatus. Direct vapor canister sampling of extraction well effluent after the air-water separator, however, provided results reasonably comparable (within 35%) to those using the vapor/condensate apparatus at the wellhead. Soil gas sampling at elevated temperatures using the vapor/condensate apparatus alleviates potential low sampling bias due to condensation.
引用
收藏
页码:85 / 89
页数:5
相关论文
共 50 条
  • [31] Getting the 1,4-dioxane out
    Bettenhausen, Craig A.
    CHEMICAL & ENGINEERING NEWS, 2020, 98 (11) : 21 - 23
  • [32] Determination of the trace 1,4-dioxane
    Guo, WQ
    Brodowsky, H
    MICROCHEMICAL JOURNAL, 2000, 64 (02) : 173 - 179
  • [33] MOLECULAR COMPOUNDS OF 1,4-DIOXANE
    DOMBROVSKII, AV
    RUSSIAN CHEMICAL REVIEWS, 1961, 30 (12): : 635 - 639
  • [34] PHARMACOKINETICS OF 1,4-DIOXANE IN HUMANS
    YOUNG, JD
    BRAUN, WH
    RAMPY, LW
    CHENOWETH, MB
    BLAU, GE
    JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH, 1977, 3 (03): : 507 - 520
  • [35] SYSTEM WATER/1,4-DIOXANE
    ROSSO, JC
    CARBONNE.L
    COMPTES RENDUS HEBDOMADAIRES DES SEANCES DE L ACADEMIE DES SCIENCES SERIE C, 1971, 272 (02): : 136 - &
  • [36] Investigating Biodegradation of 1,4-Dioxane by Groundwater and Soil Microbiomes: Insights into Microbial Ecology and Process Prediction
    Miao, Yu
    Zhou, Tianxiang
    Zheng, Xiaoru
    Mahendra, Shaily
    ACS ES&T WATER, 2023, 4 (03): : 1046 - 1060
  • [37] Detection of 1,4-dioxane in water by membrane extraction-gas chromatography/differential mobility spectrometry
    Liang Xixi
    Chen Chuang
    Wang Weiguo
    Li Haiyang
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2014, 32 (08) : 837 - 842
  • [38] AUTOIGNITIONS OF GAS-PHASE MIXTURES OF 1,4-DIOXANE AND CHLORINE
    LECLERCBATTIN, F
    MARQUAIRE, PM
    COME, GM
    BARONNET, F
    JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 1991, 4 (03) : 170 - 175
  • [39] Hydrochlorothiazide-1,4-dioxane(1/1)
    Johnston, A
    Florence, AJ
    Kennedy, AR
    ACTA CRYSTALLOGRAPHICA SECTION E-CRYSTALLOGRAPHIC COMMUNICATIONS, 2005, 61 : O2573 - O2575
  • [40] HYDROQUINONE-1,4-DIOXANE (1/1)
    BARNES, JC
    PATON, JD
    BLYTH, CS
    ACTA CRYSTALLOGRAPHICA SECTION C-CRYSTAL STRUCTURE COMMUNICATIONS, 1990, 46 : 1183 - 1184