EADC Values in Diagnosis of Renal Lesions by 3.0 T Diffusion-Weighted Magnetic Resonance Imaging: Compared with the ADC Values

被引:22
|
作者
Zhang, Yue-Lang [1 ]
Yu, Bo-Lang [1 ]
Ren, Juan [2 ]
Qu, Kai [1 ]
Wang, Ke [1 ]
Qiang, Yong-Qian [1 ]
Li, Chen-Xia [1 ]
Sun, Xing-Wang [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Med, Affiliated Hosp 1, Dept Imaging, Xian 710061, Shaanxi, Peoples R China
[2] Xi An Jiao Tong Univ, Sch Med, Affiliated Hosp 1, Dept Radiotherapy Oncol, Xian 710061, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
NEPHROGENIC SYSTEMIC FIBROSIS; CELL CARCINOMA; PATHOLOGICAL FINDINGS; PARTIAL NEPHRECTOMY; MASSES; MRI; DIFFERENTIATION; CELLULARITY; NEOPLASMS; CT;
D O I
10.1007/s00723-012-0376-z
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Exponential apparent diffusion coefficient (EADC) is an indicator of diffusion-weighted imaging (DWI) and reflects the pathological changes of tissues quantitatively. However, no study has been investigated in the space-occupying kidney disease using EADC values. This study aims to evaluate the diagnostic role of EADC values at a high magnetic field strength (3.0 T) in kidney neoplastic lesions, compared with that of the ADC values. Ninety patients with suspected renal tumors (including 101 suspected renal lesions) and 20 healthy volunteers were performed MRI scanning. Diffusion-weighted imaging was performed with a single-shot spin-echo echo-planar imaging (SE-EPI) sequence at a diffusion gradient of b = 500 s/mm(2). We found renal cell carcinoma (RCC) can be distinguished from angiomyolipoma, and clear cell carcinoma can be distinguished from non-clear cell carcinoma by EADC value. There was significant difference in overall EADC values between renal cell carcinoma (0.150 +/- A 0.059) and angiomyolipoma (0.270 +/- A 0.108) when b value was 500 s/mm(2). When receiver operating characteristic (ROC) was higher than 0.192, the sensitivity and specificity of EADC value of renal cell carcinoma were 84.6 and 81.1 %, respectively. In conclusion, EADC map shows the internal structure of the kidney tumor more intuitively than the ADC map dose, and is also in line with the observation habits of the clinicians. EADC can be used as an effective imaging method for tumor diagnosis.
引用
收藏
页码:349 / 363
页数:15
相关论文
共 50 条
  • [1] EADC Values in Diagnosis of Renal Lesions by 3.0 T Diffusion-Weighted Magnetic Resonance Imaging: Compared with the ADC Values
    Yue-Lang Zhang
    Bo-Lang Yu
    Juan Ren
    Kai Qu
    Ke Wang
    Yong-Qian Qiang
    Chen-Xia Li
    Xing-Wang Sun
    Applied Magnetic Resonance, 2013, 44 : 349 - 363
  • [2] Contribution of Diffusion-Weighted Imaging and ADC Values to Papillary Breast Lesions
    Lv, Wenjie
    Zheng, Dawen
    Guan, Wenbin
    Wu, Ping
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [3] Computed diffusion-weighted magnetic resonance imaging with high b-values in the diagnosis of gallbladder lesions
    Sato, Motokazu
    Kurita, Yusuke
    Sakai, Eiji
    Watanabe, Seitaro
    Sanada, Haruto
    Shimizu, Tomoki
    Kanoshima, Kenji
    Takai, Yusuke
    Meguro, Koki
    Sugimoto, Yuichi
    Biwata, Yusuke
    Hosono, Kunihiro
    Kobayashi, Noritoshi
    Kubota, Kensuke
    Nakajima, Atsushi
    ABDOMINAL RADIOLOGY, 2022, 47 (09) : 3278 - 3289
  • [4] Computed diffusion-weighted magnetic resonance imaging with high b-values in the diagnosis of gallbladder lesions
    Motokazu Sato
    Yusuke Kurita
    Eiji Sakai
    Seitaro Watanabe
    Haruto Sanada
    Tomoki Shimizu
    Kenji Kanoshima
    Yusuke Takai
    Koki Meguro
    Yuichi Sugimoto
    Yusuke Biwata
    Kunihiro Hosono
    Noritoshi Kobayashi
    Kensuke Kubota
    Atsushi Nakajima
    Abdominal Radiology, 2022, 47 : 3278 - 3289
  • [5] THE ROLE OF DIFFUSION-WEIGHTED MR IMAGING AND ADC VALUES IN THE DIAGNOSIS OF GASTRIC TUMORS
    Avcu, S.
    Arslan, H.
    Unal, O.
    Kotan, C.
    Izmirli, M.
    JBR-BTR, 2012, 95 (01): : 1 - 5
  • [6] Malignant renal neoplasms: correlation between ADC values and cellularity in diffusion weighted magnetic resonance imaging at 3 T
    Manenti, G.
    Di Roma, M.
    Mancino, S.
    Bartolucci, D. A.
    Palmieri, G.
    Mastrangeli, R.
    Miano, R.
    Squillaci, E.
    Simonetti, G.
    RADIOLOGIA MEDICA, 2008, 113 (02): : 199 - 213
  • [7] Diffusion-weighted imaging of the liver: usefulness of ADC values in the differential diagnosis of focal lesions and effect of ROI methods on ADC measurements
    João Pedro Filipe
    Luís Curvo-Semedo
    João Casalta-Lopes
    Maria Cristina Marques
    Filipe Caseiro-Alves
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2013, 26 : 303 - 312
  • [8] Diffusion-weighted imaging of the liver: usefulness of ADC values in the differential diagnosis of focal lesions and effect of ROI methods on ADC measurements
    Filipe, Joao Pedro
    Curvo-Semedo, Luis
    Casalta-Lopes, Joao
    Marques, Maria Cristina
    Caseiro-Alves, Filipe
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2013, 26 (03) : 303 - 312
  • [9] Application values of 3.0T magnetic resonance diffusion weighted imaging for distinguishing liver malignant tumors and benign lesions
    Li, Ruibin
    Wu, Guangyao
    Wang, Rui
    ONCOLOGY LETTERS, 2018, 15 (02) : 2091 - 2096
  • [10] Coronal Diffusion-weighted Magnetic Resonance Imaging of the Kidney: Agreement with Axial Diffusion-weighted Magnetic Imaging in Terms of Apparent Diffusion Coefficient Values
    Wang, Hai-Yi
    Wang, Jia
    Tang, Ye-Huan
    Ye, Hui-Yi
    Ma, Lin
    CHINESE MEDICAL JOURNAL, 2015, 128 (04) : 499 - 503