Association between the amount of right-to-left shunt and infarct patterns in patients with cryptogenic embolic stroke: a transcranial Doppler study

被引:20
|
作者
Kim, Ji Won [1 ]
Kim, Suk Jae [1 ]
Yoon, Cindy W. [1 ]
Park, Chang-Hyun [2 ]
Kang, Kun Woo [1 ]
Kim, Soo Kyoung [1 ]
Kim, Yun-Hee [2 ]
Bang, Oh Young [1 ]
机构
[1] Sungkyunkwan Univ, Samsung Med Ctr, Stroke & Cerebrovasc Ctr, Dept Neurol,Sch Med, Seoul 135710, South Korea
[2] Sungkyunkwan Univ, Samsung Med Ctr, Dept Phys Med & Rehabil, Div Neurorehabil,Sch Med, Seoul 135710, South Korea
关键词
cryptogenic stroke; diffusion weighted MRI; ischemic; paradoxical embolism; patent foramen ovale; stroke; PATENT FORAMEN OVALE; ISCHEMIC-STROKE; PARADOXICAL EMBOLISM; SEPTAL ABNORMALITIES; ULTRASOUND; SIZE; IDENTIFICATION; MULTICENTER; CRITERIA;
D O I
10.1111/j.1747-4949.2012.00846.x
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BackgroundParadoxical embolism has been documented as a mechanism of cryptogenic embolic stroke. We investigated the frequency of right-to-left shunt in patients with cryptogenic embolic stroke and evaluated the factors associated with diffusion-weighted imaging (DWI) lesion pattern. MethodsWe analyzed data on 157 consecutive patients with acute ischemic stroke because of presumed cryptogenic embolism. Agitated saline transcranial Doppler study was conducted in all patients to detect right-to-left shunt. We evaluated the association of the amount (microemboli <20 vs. 20) and activity (spontaneous vs. after Valsalva maneuver only) of right-to-left shunt with diffusion-weighted imaging lesion patterns. ResultsRight-to-left shunt was observed in 96 (61<bold>1</bold>%) patients. The multiplicity and distribution of diffusion-weighted imaging lesions did not differ depending on the amount and activity of right-to-left shunt. However, the size of diffusion-weighted imaging lesions differed depending on the amount of right-to-left shunt (P=0<bold>019</bold>). Right-to-left shunt was more frequently observed in patients with small (<1cm) infarcts than in those with a large infarct (66<bold>7</bold>% vs. 45<bold>9</bold>%), and most patients with a larger amount of right-to-left shunt were found to have small infarcts on diffusion-weighted imaging (80%). The clinical characteristics, including Framingham stroke risk strategy, did not differ between the groups. ConclusionsOur results indicate that the amount of right-to-left shunt determines the Diffusion-weighted imaging lesion patterns and suggest that mechanisms of stroke other than paradoxical mechanism may play an important role in patients with large cryptogenic embolic stroke.
引用
收藏
页码:657 / 662
页数:6
相关论文
共 50 条
  • [31] Alternatives to transtemporal approach of transcranial Doppler for the detection of right-to-left cardiac shunt
    Sharma, Vijay K.
    Teoh, Hock L.
    Chan, Bernard P. L.
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2009, 279 (1-2) : 124 - 125
  • [32] Enhanced detection of right-to-left shunt by transcranial doppler: Comparison of various maneuvers
    Selim, Magdy H.
    LaFrance, Casey
    STROKE, 2007, 38 (02) : 491 - 491
  • [33] Cluster headache and right-to-left shunt on contrast transcranial Doppler - A case-control study
    Finocchi, C
    Del Sette, M
    Angeli, S
    Rizzi, D
    Gandolfo, C
    NEUROLOGY, 2004, 63 (07) : 1309 - 1310
  • [34] Transcranial Doppler with Bubble Study as a Method to Detect Extracardiac Right-to-Left Shunts in Patients with Ischemic Stroke
    Goutman, Stephen A.
    Katzan, Irene L.
    Gupta, Rishi
    JOURNAL OF NEUROIMAGING, 2013, 23 (04) : 523 - 525
  • [35] Right-to-left shunt assessed by contrast transcranial Doppler sonography - New insights
    Uzuner, N
    Horner, S
    Pichler, G
    Svetina, D
    Niederkorn, K
    JOURNAL OF ULTRASOUND IN MEDICINE, 2004, 23 (11) : 1475 - 1482
  • [36] Detection of Right-to-Left Shunt With Transcranial Doppler Is Affected by Body-Positioning
    Tsivgoulis, Georgios
    Sharma, Vijay K.
    Alexandrov, Andrei V.
    STROKE, 2008, 39 (11) : E184 - E184
  • [37] Contrast transcranial Doppler compared to transesophageal echocardiography in detection of right-to-left shunt
    Hamzehloo, Ali
    Mousavi, Seida A.
    NEUROSCIENCES, 2006, 11 (03) : 167 - 170
  • [38] Low sensitivity of the echocardiograph compared with contrast transcranial doppler in right-to-left shunt
    Martinez-Sanchez, P.
    Medina-Baez, J.
    Lara-Lara, M.
    Oliva-Navarro, J.
    Cazorla-Garcia, R.
    Ruiz-Ares, G.
    Martinez-Martinez, M.
    Fuentes, B.
    Diez-Tejedor, E.
    NEUROLOGIA, 2012, 27 (02): : 61 - 67
  • [39] Detection of right-to-left shunt with ultrasound contrast agent and transcranial Doppler sonography
    Jauss, M
    Zanette, E
    CEREBROVASCULAR DISEASES, 2000, 10 (06) : 490 - 496
  • [40] EFFECTS OF PATIENT POSITION ON RIGHT-TO-LEFT SHUNT DETECTION BY CONTRAST TRANSCRANIAL DOPPLER
    Wu, Chun-Tao
    Han, Ke
    Guo, Zhen-Ni
    Yang, Yi
    Gao, Yong-Sheng
    Bai, Jing
    Xing, Ying-Qi
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (03): : 654 - 658