ORGAN ABSORBED DOSE ESTIMATION REFLECTING SPECIFIC ORGAN MASSES WITH SIMPLE SCALING OF REFERENCE DOSES USING THE ORGAN MASSES

被引:1
|
作者
Manabe, Kentaro [1 ,2 ]
Koyama, Shuji [3 ]
机构
[1] Nagoya Univ, Grad Sch Med, Nagoya, Aichi 4618673, Japan
[2] Japan Atom Energy Agcy, Nucl Sci & Engn Ctr, Tokai, Ibaraki 3191195, Japan
[3] Nagoya Univ, Brain & Mind Res Ctr, Nagoya, Aichi 4618673, Japan
关键词
IODINE;
D O I
10.1093/rpd/ncaa058
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Estimating organ absorbed doses in consideration of person-specific parameters is important for radiation protection in diagnostic nuclear medicine. This study proposes a straightforward method for estimating the organ dose that reflects a specific organ mass by scaling the reference organ dose using the inverse ratio of the specific organ mass to the reference organ mass. For the administration of radiopharmaceuticals labelled by Tc-99m or I-123, the organ doses for the liver, spleen, red marrow and thyroid obtained by the method were compared with those generated by a Monte Carlo simulation. The discrepancies were less than 14% for the liver, spleen and thyroid. Conversely, in some cases, the red marrow discrepancies were greater than 30% due to the wide distribution of red marrow in the trunk and head regions. This study confirms that the method of scaling organ doses can be effective for estimating mass-specific doses for solid organs.
引用
收藏
页码:489 / 496
页数:8
相关论文
共 50 条
  • [31] Brachytherapy organ dose estimation using Monte Carlo simulations of realistic patient models
    Morato, S.
    Juste, B.
    Peris, S.
    Miro, R.
    Verdu, G.
    Ballester, F.
    Vijande, J.
    [J]. 2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 6149 - 6152
  • [32] Organ Dose Estimation Accuracy Using a Modified SSDE for CT Examination in a Pediatric Population
    Deaton, N.
    Kaufman, R.
    Somasundarum, E.
    Brady, S.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 3316 - 3317
  • [33] Evaluation of deep learning segmentation for rapid, patient-specific CT organ dose estimation using an LBTE solver
    Offe, Michael
    Fraley, David
    Adamson, Philip M.
    Principi, Sara
    Wang, Adam S.
    Jordan, Petr
    Schmidt, Taly Gilat
    [J]. MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [34] A method of rapid quantification of patient-specific organ doses for CT using deep-learning-based multi-organ segmentation and GPU-accelerated Monte Carlo dose computing
    Peng, Zhao
    Fang, Xi
    Yan, Pingkun
    Shan, Hongming
    Liu, Tianyu
    Pei, Xi
    Wang, Ge
    Liu, Bob
    Kalra, Mannudeep K.
    Xu, X. George
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : 2526 - 2536
  • [35] EVALUATION OF ORGAN DOSES IN BRACHYTHERAPY TREATMENT OF UTERUS CANCER USING MATHEMATICAL REFERENCE INDIAN ADULT PHANTOM
    Biju, K.
    [J]. RADIATION PROTECTION DOSIMETRY, 2012, 148 (02) : 185 - 188
  • [36] Size-Specific Dose Estimate (SSDE) Provides a Simple Method to Calculate Organ Dose for Pediatric CT Examinations
    Moore, B.
    Brady, S.
    Mirro, A.
    Kaufman, R.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 424 - +
  • [37] Size-specific dose estimate (SSDE) provides a simple method to calculate organ dose for pediatric CT examinations
    Moore, Bria M.
    Brady, Samuel L.
    Mirro, Amy E.
    Kaufman, Robert A.
    [J]. MEDICAL PHYSICS, 2014, 41 (07)
  • [38] Evaluation of organ doses and specific k effective dose of 64-slice CT thorax examination using an adult anthropomorphic phantom
    Hashim, S.
    Karim, M. K. A.
    Bakar, K. A.
    Sabarudin, A.
    Chin, A. W.
    Saripan, M. I.
    Bradley, D. A.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2016, 126 : 14 - 20
  • [39] Estimation of organ and effective doses of CBCT scans of radiotherapy using size-specific field of view (FOV): a Monte Carlo study
    Abuhaimed, Abdullah
    Mujammami, Huda
    Alenazi, Khaled
    Abanomy, Ahmed
    Alashban, Yazeed
    Martin, Colin J.
    [J]. PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, 47 (03) : 895 - 906
  • [40] From patient-informed to patient-specific organ dose estimation in clinical computed tomography
    Fu, Wanyi
    Segars, William P.
    Abadi, Ehsan
    Sharma, Shobhit
    Kapadia, Anuj J.
    Samei, Ehsan
    [J]. MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573