ORGAN ABSORBED DOSE ESTIMATION REFLECTING SPECIFIC ORGAN MASSES WITH SIMPLE SCALING OF REFERENCE DOSES USING THE ORGAN MASSES

被引:1
|
作者
Manabe, Kentaro [1 ,2 ]
Koyama, Shuji [3 ]
机构
[1] Nagoya Univ, Grad Sch Med, Nagoya, Aichi 4618673, Japan
[2] Japan Atom Energy Agcy, Nucl Sci & Engn Ctr, Tokai, Ibaraki 3191195, Japan
[3] Nagoya Univ, Brain & Mind Res Ctr, Nagoya, Aichi 4618673, Japan
关键词
IODINE;
D O I
10.1093/rpd/ncaa058
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Estimating organ absorbed doses in consideration of person-specific parameters is important for radiation protection in diagnostic nuclear medicine. This study proposes a straightforward method for estimating the organ dose that reflects a specific organ mass by scaling the reference organ dose using the inverse ratio of the specific organ mass to the reference organ mass. For the administration of radiopharmaceuticals labelled by Tc-99m or I-123, the organ doses for the liver, spleen, red marrow and thyroid obtained by the method were compared with those generated by a Monte Carlo simulation. The discrepancies were less than 14% for the liver, spleen and thyroid. Conversely, in some cases, the red marrow discrepancies were greater than 30% due to the wide distribution of red marrow in the trunk and head regions. This study confirms that the method of scaling organ doses can be effective for estimating mass-specific doses for solid organs.
引用
收藏
页码:489 / 496
页数:8
相关论文
共 50 条
  • [1] GENERALIZED-APPROACH TO ABSORBED DOSE CALCULATIONS FOR DYNAMIC TUMOR AND ORGAN MASSES
    GODDU, SM
    HOWELL, RW
    RAO, DV
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1995, 36 (10) : 1923 - 1927
  • [2] THE MAYAK WORKER DOSIMETRY SYSTEM-2013: TREATMENT OF ORGAN MASSES IN THE CALCULATION OF ORGAN DOSES
    Birchall, A.
    Sokolova, A. B.
    [J]. RADIATION PROTECTION DOSIMETRY, 2017, 176 (1-2) : 102 - 105
  • [3] Estimation of absorbed organ doses and effective dose based on body mass index in digital radiography
    Kim, HyunJi
    Park, MinSeok
    Park, SongYi
    Jeong, HoiWoun
    Kim, Jungmin
    Kim, Youhyun
    [J]. RADIATION PROTECTION DOSIMETRY, 2013, 153 (01) : 92 - 99
  • [4] Scaling of organ masses in mammals and birds: phylogenetic signal and implications for metabolic rate scaling
    Antol, Andrzej
    Kozlowski, Jan
    [J]. ZOOKEYS, 2020, (982) : 149 - 159
  • [5] Simple methods for the estimation of dose distributions, organ doses and energy imparted in paediatric radiology
    Almen, A
    Nilsson, M
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (07): : 1093 - 1105
  • [6] ESTIMATION OF THE ORGAN ABSORBED DOSES AND EFFECTIVE DOSE FROM 68Ga-PSMA-11 PET SCAN
    Demirci, Emre
    Toklu, Turkay
    Yeyin, Nami
    Ocak, Meltem
    Alan-Selcuk, Nalan
    Araman, Ahmet
    Kabasakal, Levent
    [J]. RADIATION PROTECTION DOSIMETRY, 2018, 182 (04) : 518 - 524
  • [7] Computed Tomography Chest and Abdomen Organ Doses Estimation Using a Dose Management Tool
    Tsapaki, V.
    Fitousi, N.
    Caracappa, P.
    Jacobs, J.
    Papailiou, I.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 3071 - 3071
  • [8] Rapid estimation of patient-specific organ doses using a deep learning network
    Myronakis, Marios
    Stratakis, John
    Damilakis, John
    [J]. MEDICAL PHYSICS, 2023, 50 (11) : 7236 - 7244
  • [9] Simplified approach to estimation of organ absorbed doses for patients undergoing abdomen and pelvis CT examination
    Sookpeng, S.
    Martin, C. J.
    Lopez-Gonzalez, M. R.
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2021, 41 (04) : 1288 - 1303
  • [10] ESTIMATION OF ORGAN BIODISTRIBUTION AND ABSORBED DOSE FROM EXTERNAL MEASUREMENT WITH TLDS IN PET STUDIES
    MATSUMOTO, M
    NAKAMURA, T
    WATABE, H
    ITOH, M
    HATAZAWA, J
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1993, 31 : S151 - S156