Effect of Decentration on the Optical Quality of Monofocal, Extended Depth of Focus, and Bifocal Intraocular Lenses

被引:32
|
作者
Xu, Jie [1 ,2 ,3 ,4 ]
Zheng, Tianyu [1 ,2 ,3 ,4 ]
Lu, Yi [1 ,2 ,3 ,4 ]
机构
[1] Fudan Univ, Eye & Ear Nose & Throat Hosp, Dept Ophthalmol, Shanghai, Peoples R China
[2] Fudan Univ, Eye & Ear Nose & Throat Hosp, Eye Inst, Shanghai, Peoples R China
[3] Minist Hlth, Key Lab Myopia, Shanghai, Peoples R China
[4] Shanghai Key Lab Visual Impairment & Restorat, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
TILT; PERFORMANCE; RANGE;
D O I
10.3928/1081597X-20190708-02
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the effect of intraocular lens (IOL) decentration on the optical quality in patients with implantation of three IOLs: monofocal, extended depth of focus (EDOF), and bifocal. METHODS: Patients had cataract surgery with implantation of one of the three above-mentioned IOLs. Higher order aberrations (HOAs), modulation transfer function (MTF), point spread function (PSF), retinal straylight, and dysphotopsia phenomena were evaluated 3 months after surgery. IOL decentration was quantified as the distance between the visual axis center and the IOL center using the OPD-Scan III aberrometer (Nidek Co., Ltd., Gamagori, Japan). The patients who received each IOL type were then divided into two subgroups (decentration of <= 0.25 or > 0.25 mm) to analyze the effect of IOL decentration on these optical qualities. RESULTS: The study included 54 eyes (54 patients), with 18 eyes in each IOL group. The distance of IOL decentration did not differ significantly among the three groups. With a decentration of more than 0.25 mm, MTF, PSF, and coma were only significantly deteriorated in the bifocal IOL (ZMB00; Abbott Medical Optics, Santa Ana, CA). HOAs, coma, PSF, and glare perception were better in the monofocal and EDOF IOLs than those in the ZMB00 IOL when decentration was more than 0.25 mm. Furthermore, IOL decentration was significantly correlated with HOAs, coma, MTF, and PSF in the ZMB00 IOL. CONCLUSIONS: The monofocal and EDOF IOLs are more immune to optical quality degradation caused by IOL decentration than the ZMB00 IOL.
引用
收藏
页码:484 / +
页数:10
相关论文
共 50 条
  • [31] Current Review: Multifocal Intraocular Lenses and Extended Depth of Focus Intraocular Lenses
    Breyer, Detlev R. H.
    Beckers, Lena
    Ax, Timon
    Kaymak, Hakan
    Klabe, Karsten
    Kretz, Florian Tobias Alwin
    [J]. KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2020, 237 (08) : 943 - 957
  • [32] The effect of trifocal and extended-depth-of-focus intraocular lenses on optical coherence tomography parameters
    Sezenoz, Almila Sarigul
    Gungor, Sirel Gur
    Dogan, Irem Kirci
    Colak, Meric Yavuz
    Gokgoz, Gulsah
    Altinors, Dilek Dursun
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2024, 72 (SUPPL 3) : S423 - S428
  • [33] Effect of blocking violet light in extended depth of focus intraocular lenses
    Faria-Ribeiro, Miguel
    Jenkins, Mark
    Rosen, Robert
    van der Mooren, Marrie
    Canovas, Carmen
    Piers, Patricia
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [34] Effect of Decentration on the Optical Performance in Multifocal Intraocular Lenses
    Soda, Mitsutaka
    Yaguchi, Shigeo
    [J]. OPHTHALMOLOGICA, 2012, 227 (04) : 197 - 204
  • [35] Refraction, anterior chamber depth, decentration, and tilt after implantation of monofocal and multifocal silicone intraocular lenses
    Dick, HB
    Schwenn, O
    Krummenauer, F
    Weidler, S
    Pfeiffer, N
    [J]. OPHTHALMOLOGE, 2001, 98 (04): : 380 - 386
  • [36] Comparative analysis of a presbyopia-correcting intraocular lens that combines extended depth-of-focus and bifocal profiles with a standard monofocal intraocular lens
    Shin, Da Eun
    Lee, Hun
    Koh, Kyungmin
    [J]. BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [37] Depth of focus extended intraocular lenses and their optical performances in a pseudophakic eye model
    Wang, Zhao-Qi
    Rao, Feng
    Liu, Yong-Ji
    [J]. 5TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: ADVANCED OPTICAL MANUFACTURING TECHNOLOGIES, 2010, 7655
  • [38] Comparison of two extended depth of focus intraocular lenses with a monofocal lens: a multi-centre randomised trial
    Reinhard, Thomas
    Maier, Philip
    Boehringer, Daniel
    Bertelmann, Eckart
    Brockmann, Tobias
    Kiraly, Laszlo
    Salom, David
    Piovella, Matteo
    Colonval, Stephane
    Mendicute, Javier
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2021, 259 (02) : 431 - 442
  • [39] Comparison of two extended depth of focus intraocular lenses with a monofocal lens: a multi-centre randomised trial
    Thomas Reinhard
    Philip Maier
    Daniel Böhringer
    Eckart Bertelmann
    Tobias Brockmann
    Laszlo Kiraly
    David Salom
    Matteo Piovella
    Stephane Colonval
    Javier Mendicute
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2021, 259 : 431 - 442
  • [40] Comparative analysis of a presbyopia-correcting intraocular lens that combines extended depth-of-focus and bifocal profiles with a standard monofocal intraocular lens
    Da Eun Shin
    Hun Lee
    Kyungmin Koh
    [J]. BMC Ophthalmology, 22