Quality of vision after cataract surgery after Tecnis Z9000 intraocular lens implantation - Effect of contrast sensitivity and wavefront aberration improvements on the quality of daily vision

被引:101
|
作者
Denoyer, Alexandre [1 ]
Le Lez, Marie-Laure [1 ]
Majzoub, Samuel [1 ]
Pisella, Pierre-Jean [1 ]
机构
[1] Univ Hosp Tours, Dept Ophthalmol, F-37000 Tours, France
来源
关键词
D O I
10.1016/j.jcrs.2006.10.035
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare ocular performance and quality of vision in pseuclophakic eyes with an aspherical intraocular lens (IOL) or a conventional spherical IOL. SETTING: Bretonneau University Hospital, Tours, France. METHODS: Twenty patients (40 eyes) were randomly divided in 2 equal groups to bilaterally receive the aspherical Tecnis Z9000 IOL (AMO) or the spherical CeeOn Edge 911 IOL (AMO). Contrast sensitivity was measured and ocular wavefront analysis performed before surgery and 6 months after. Patients completed the Activities of Daily Vision Scale (ADVS) to evaluate patient-centered visual outcomes. Other examinations included refraction before and after mydriasis and pupil diameter. RESULTS: The mean postoperative best corrected visual acuity (logMAR) was 0.03 +/- 0.05 (SD) in the Tecnis group and 0.01 +/- 0.05 in the CeeOn Edge group (P =.41). Refractive evaluation with mydriasis showed a mean myopic shift as low as -0.02 +/- 0.36 diopter (D) in the Tecnis group and -0.51 +/- 0.37 D in the CeeCin Edge group (P =.001). Mesopic contrast sensitivity at high spatial frequencies was significantly better in the Tecnis group (<.001), while contrast sensitivity under photopic and glare conditions was not different between the 2 groups. Spherical aberration was significantly lower in the Tecnis group, which had a mean Z(4)(0) of 0-01 +/- 0.06 mu m, than in the CeeOn Edge group, which had a mean Z(4)(0) of 0.16 +/- 0.12 mu m (P <.001). The global score on the ADVS was not statistically different between groups; however, quality of distance vision was better in the Tecnis group than in the CeeCin Edge group (mean 99.0 +/- 2.0 versus 89.2 +/- 3.4) (P <.001). CONCLUSION: Implantation of an aspherical IOL with a negative spherical aberration resulted in reduced ocular spherical aberration and improved mesopic contrast sensitivity and led to better subjective quality of vision.
引用
收藏
页码:210 / 216
页数:7
相关论文
共 50 条
  • [31] Clinical Outcomes and Quality of Vision Associated with Bilateral Implantation of a Wavefront Shaping Presbyopia Correcting Intraocular Lens
    Gundersen, Kjell Gunnar
    Potvin, Richard
    [J]. CLINICAL OPHTHALMOLOGY, 2021, 15 : 4723 - 4730
  • [32] A comparative study on early vision quality after implantation of refractive segmental and diffractive multifocal intraocular lens
    Lian, Huifang
    Ma, Weisong
    Wei, Qiuhong
    Yuan, Xiaoyong
    [J]. PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2020, 36 (07) : 1607 - 1612
  • [33] Health-related quality of life after cataract surgery with the phacoemulsification technique and intraocular lens implantation
    Porela-Tiihonen, Susanna
    Roine, Risto P.
    Sintonen, Harri
    Kaarniranta, Kai
    Kokki, Merja
    Kokki, Hannu
    [J]. ACTA OPHTHALMOLOGICA, 2016, 94 (01) : 21 - 25
  • [34] High order aberration and straylight evaluation after cataract surgery with implantation of an aspheric, aberration correcting monofocal intraocular lens
    Kretz, Florian T. A.
    Tandogan, Tamer
    Khoramnia, Ramin
    Auffarth, Gerd U.
    [J]. INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2015, 8 (04) : 736 - 741
  • [35] High order aberration and straylight evaluation after cataract surgery with implantation of an aspheric,aberration correcting monofocal intraocular lens
    Florian T A Kretz
    Tamer Tandogan
    Ramin Khoramnia
    Gerd U Auffarth
    [J]. International Journal of Ophthalmology, 2015, 8 (04) : 736 - 741
  • [36] Visual acuity, contrast sensitivity, and quality of life after bilateral implantation of multifocal diffractive intraocular lens
    Queiroz, Marjorie F. N.
    Ferreira, Felipe Q. T.
    Shimoda, Gilberto
    Padovani, Carlos Roberto
    Lottelli, Antonio C.
    [J]. ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2023, 86 (04) : 301 - 307
  • [37] Ocular aberrations and contrast sensitivity after cataract surgery with AcrySof IQ intraocular lens implantation: Clinical comparative study
    Tzelikis, Patrick F.
    Akaishi, Leonardo
    Trindade, Fernando C.
    Boteon, Joel E.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (11): : 1918 - 1924
  • [38] Effect on contrast sensitivity after clear, yellow and orange intraocular lens implantation
    Bandyopadhyay, Sabyasachi
    Saha, Mita
    Chakrabarti, Asim
    Sinha, Abhik
    [J]. INTERNATIONAL OPHTHALMOLOGY, 2016, 36 (03) : 313 - 318
  • [39] Effect on contrast sensitivity after clear, yellow and orange intraocular lens implantation
    Sabyasachi Bandyopadhyay
    Mita Saha
    Asim Chakrabarti
    Abhik Sinha
    [J]. International Ophthalmology, 2016, 36 : 313 - 318
  • [40] Influence of Corneal Spherical Aberration and Intraocular Lens Asphericity on Optical Quality After Cataract Removal
    Kohnen, T.
    Hofmann, C.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)