Postoperative Changes in Body Composition After Pancreaticoduodenectomy Using Multifrequency Bioelectrical Impedance Analysis

被引:15
|
作者
Mikamori, Manabu [1 ,2 ]
Miyamoto, Atsushi [1 ]
Asaoka, Tadafumi [1 ,2 ]
Maeda, Sakae [1 ]
Hama, Naoki [1 ]
Yamamoto, Kazuyoshi [1 ]
Hirao, Motohiro [1 ]
Ikeda, Masataka [1 ]
Sekimoto, Mitsugu [1 ]
Doki, Yuichiro [2 ]
Mori, Masaki [2 ]
Nakamori, Shoji [1 ]
机构
[1] Osaka Natl Hosp, Natl Hosp Org, Dept Surg Gastroenterol, Chuo Ku, 2-1-14 Hoenzaka, Osaka 5400006, Japan
[2] Osaka Univ, Grad Sch Med, Dept Surg Gastroenterol, 2-2 Yamadaoka, Suita, Osaka 5650871, Japan
关键词
Body weight; Body composition; Pancreaticoduodenectomy; Gastrectomy; Multifrequency bioelectrical impedance analysis; QUALITY-OF-LIFE; STOMACH-PRESERVING PANCREATICODUODENECTOMY; PERIAMPULLARY ADENOCARCINOMA; NUTRITIONAL-STATUS; BIOIMPEDANCE ANALYSIS; SURGICAL-MANAGEMENT; SURVIVAL; GASTRECTOMY; PYLORUS; CANCER;
D O I
10.1007/s11605-015-3055-1
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background Nutritional status is one of the most important clinical determinants of outcome after surgery. The aim of this study was to compare changes in the body composition of patients undergoing pancreaticoduodenectomy (PD), distal gastrectomy (DG), or total gastrectomy (TG). Methods The parameters of body composition were measured using multifrequency bioelectrical impedance analysis with an inBody 720 (Biospace Inc. Tokyo. Japan) in 60 patients who had undergone PD (n=18), DG(n=30), or TG(n=12). None of the patients had recurrence or were treated with chemotherapy. Changes between the preoperative data and results and those obtained 12 months after surgery were evaluated. Results Twelve months after surgery, the body weight change in the PD group was significantly lower than in the TG and DG groups (-1.2 +/- 3.8 vs -7.4 +/- 4.4 and -4.0 +/- 3.2 kg, respectively; p<0.01 vs TG, p<0.05 vs DG). The body weight change correlated with the fat mass change in all groups. Conclusions The type and extent of surgery has a different effect on long-term body weight and body composition. Bioelectric impedance analysis can be used to assess body composition and may be useful for nutritional assessment in patients who have undergone these surgeries.
引用
收藏
页码:611 / 618
页数:8
相关论文
共 50 条
  • [31] The reliability of bioelectrical impedance analysis for measuring changes in the body composition of patients with anorexia nervosa
    Birmingham, CL
    Jones, PJH
    Orphanidou, C
    Bakan, R
    Cleator, IGM
    Goldner, EM
    Phang, PT
    INTERNATIONAL JOURNAL OF EATING DISORDERS, 1996, 19 (03) : 311 - 315
  • [32] Bioelectrical Impedance Analysis for the Prediction of Human Body Composition Using Wenner Algorithm
    Guerrero, Dean Henry S.
    Lapada, Christine S.
    Necesito, Ronnie Ray R.
    Lazaro, Jose B.
    Yumang, Analyn N.
    Dimaunahan, Ericson D.
    2019 IEEE 11TH INTERNATIONAL CONFERENCE ON HUMANOID, NANOTECHNOLOGY, INFORMATION TECHNOLOGY, COMMUNICATION AND CONTROL, ENVIRONMENT, AND MANAGEMENT (HNICEM), 2019,
  • [33] ESTIMATION OF RAT-BODY COMPOSITION USING TETRAPOLAR BIOELECTRICAL IMPEDANCE ANALYSIS
    HALL, CB
    LUKASKI, HC
    MARCHELLO, MJ
    NUTRITION REPORTS INTERNATIONAL, 1989, 39 (03): : 627 - 633
  • [34] Examination of the body composition of patients with Werner syndrome using bioelectrical impedance analysis
    Tanaka, Fumihiko
    Kuzuya, Masafumi
    GERIATRICS & GERONTOLOGY INTERNATIONAL, 2022, 22 (01) : 75 - 80
  • [35] A MODEL FOR ASSESSING BODY-COMPOSITION IN AMPUTEES USING BIOELECTRICAL IMPEDANCE ANALYSIS
    VETTORAZZI, C
    BARILLAS, C
    PINEDA, O
    FEDERATION PROCEEDINGS, 1987, 46 (04) : 1186 - 1186
  • [36] BIOELECTRICAL IMPEDANCE AND BODY-COMPOSITION
    DEVRIES, PMJM
    KOUW, PM
    OLTHOF, CG
    DEVRIES, JPPM
    DONKER, AJM
    LANCET, 1993, 341 (8844): : 570 - 570
  • [37] BIOELECTRICAL IMPEDANCE AND BODY-COMPOSITION
    WALKER, M
    RODHAM, D
    FULCHER, GR
    CLAYTON, B
    FARRER, M
    ALBERTI, KGMM
    LANCET, 1993, 341 (8842): : 448 - 448
  • [38] Bioelectrical impedance spectroscopy and body composition
    Chumlea, WC
    Siervogel, RM
    Wu, YX
    Hall, G
    Guo, SS
    IN VIVO BODY COMPOSITION STUDIES, 2000, 904 : 210 - 213
  • [39] The measurement of body composition by bioelectrical impedance
    Popa, Monica
    Sirbu, Dana
    Curseu, Daniela
    Ionutas, Alina
    2006 IEEE-TTTC INTERNATIONAL CONFERENCE ON AUTOMATION, QUALITY AND TESTING, ROBOTICS, VOL 2, PROCEEDINGS, 2006, : 437 - 440
  • [40] Changes in body composition in adolescents with anorexia nervosa - Comparison of bioelectrical impedance analysis and total body potassium
    Wotton, MJ
    Trocki, O
    Thomas, BJ
    Hammond, P
    Shepherd, RW
    Lewindon, PJ
    Wilcox, J
    Murphy, AJ
    Cleghorn, GJ
    IN VIVO BODY COMPOSITION STUDIES, 2000, 904 : 418 - 419