Experimental evaluation of an inertial mass damper and its analytical model for cable vibration mitigation

被引:21
|
作者
Lu, Lei [1 ]
Fermandois, Gaston A. [2 ]
Lu, Xilin [1 ]
Spencer, Billie F., Jr. [2 ]
Duan, Yuan-Feng [3 ]
Zhou, Ying [1 ]
机构
[1] Tongji Univ, State Key Lab Disaster Reduct Civil Engn, Shanghai 200092, Peoples R China
[2] Univ Illinois, Dept Civil & Environm Engn, Urbana, IL 61801 USA
[3] Zhejiang Univ, Coll Civil Engn & Architecture, Hangzhou 310058, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
stay cable; inerter; inertial mass damper; performance test; nonlinearities; real-time hybrid simulation test; DISCRETE OIL DAMPERS; ON TMD SYSTEM; OPTIMAL-DESIGN; 3-DIMENSIONAL VIBRATION; ATTACHED DAMPER; STAY CABLE; TAUT CABLE; PERFORMANCE; REDUCTION; DEVICE;
D O I
10.12989/sss.2019.23.6.589
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Cables are prone to vibration due to their low inherent damping characteristics. Recently, negative stiffness dampers have gained attentions, because of their promising energy dissipation ability. The viscous inertial mass damper (termed as VIMD hereinafter) can be viewed as one realization of the inerter. It is formed by paralleling an inertial mass part with a common energy dissipation element (e.g., viscous element) and able to provide pseudo-negative stiffness properties to flexible systems such as cables. A previous study examined the potential of IMD to enhance the damping of stay cables. Because there are already models for common energy dissipation elements, the key to establish a general model for IMD is to propose an analytical model of the rotary mass component. In this paper, the characteristics of the rotary mass and the proposed analytical model have been evaluated by the numerical and experimental tests. First, a series of harmonic tests are conducted to show the performance and properties of the IMD only having the rotary mass. Then, the mechanism of nonlinearities is analyzed, and an analytical model is introduced and validated by comparing with the experimental data. Finally, a real-time hybrid simulation test is conducted with a physical IMD specimen and cable numerical substructure under distributed sinusoidal excitation. The results show that the chosen model of the rotary mass part can provide better estimation on the damper's performance, and it is better to use it to form a general analytical model of IMD. On the other hand, the simplified damper model is accurate for the preliminary simulation of the cable responses.
引用
收藏
页码:589 / 613
页数:25
相关论文
共 50 条
  • [21] Free vibration of a taut cable with a damper and a concentrated mass
    Zhou, Haijun
    Huang, Xigui
    Xiang, Ning
    He, Jiawei
    Sun, Limin
    Xing, Feng
    STRUCTURAL CONTROL & HEALTH MONITORING, 2018, 25 (11):
  • [22] Vibration mitigation of stay cable using optimally tuned MR damper
    Huang, Hongwei
    Sun, Limin
    Jiang, Xiaolu
    SMART STRUCTURES AND SYSTEMS, 2012, 9 (01) : 35 - 53
  • [23] Self-powered hybrid electromagnetic damper for cable vibration mitigation
    Jamshidi, Maziar
    Chang, C. C.
    Bakhshi, Ali
    SMART STRUCTURES AND SYSTEMS, 2017, 20 (03) : 285 - 301
  • [24] FULL-SCALE TEST OF FRICTION DAMPER FOR CABLE VIBRATION MITIGATION
    Zhou, Hai-Jun
    Sun, Li-Min
    PROCEEDINGS OF THE TENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING FOR YOUNG EXPERTS, VOLS I AND II, 2008, : 1277 - 1282
  • [25] Impact of cable sag on the efficiency of an inertial mass damper in controlling stay cable vibrations
    Wang, Zhi-hao
    Gao, Hui
    Xu, Yan-wei
    Chen, Zheng-qing
    Wang, Hao
    SMART STRUCTURES AND SYSTEMS, 2019, 24 (01) : 83 - 94
  • [26] Experimental study on mitigation of ice-induced vibration for offshore platforms with a tuned mass damper
    Zhang, L.
    Yue, Q-J
    Zhang, W-S
    Hsiao, C.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART M-JOURNAL OF ENGINEERING FOR THE MARITIME ENVIRONMENT, 2008, 222 (M3) : 121 - 132
  • [27] Vibration Damping of a Taut Cable with the Hybrid Application of a Viscous Damper and a Tuned Mass Damper
    Yang, Xia
    Zhou, Haijun
    Cai, Chunsheng
    Huang, Xigui
    Du, YanLiang
    JOURNAL OF BRIDGE ENGINEERING, 2024, 29 (05)
  • [28] Experimental study of vibration control of a cable with an attached MR damper
    Maslanka, Marcin
    Sapinski, Bogdan
    Snamina, Jacek
    JOURNAL OF THEORETICAL AND APPLIED MECHANICS, 2007, 45 (04) : 893 - 917
  • [29] Analytical study on the effects of flexural rigidity and negative stiffness in the optimal tuning of inerter-based damper for cable vibration mitigation
    Shi, Xiang
    Ma, Junchi
    Xing, Lanchang
    Li, Jin-Yang
    Zhu, Songye
    ADVANCES IN STRUCTURAL ENGINEERING, 2022, 25 (16) : 3316 - 3333
  • [30] Experimental investigation on amplified multilayer viscoelastic damper and vibration mitigation evaluation subjected to wind loads
    Shang, Feng
    Liu, Wenguang
    Xu, Hao
    Zhang, Qiang
    JOURNAL OF BUILDING ENGINEERING, 2023, 75