A comparative study of chemical modifiers in the determination of total arsenic in marine food by tungsten coil electrothermal atomic absorption spectrometry

被引:16
|
作者
Bruhn, Carlos G.
Bustos, Catherine J.
Saez, Katia L.
Neira, Jose Y.
Alvarez, Solange E.
机构
[1] Univ Concepcion, Fac Farm, Dept Analisis Instrumental, Concepcion 4039200, Chile
[2] Univ Concepcion, Fac Ciencias Fis & Matemat, Dept Estadist, Concepcion 4039200, Chile
关键词
chemical modifiers; arsenic; tungsten coil electrothermal atomizer; sample pretreatment; lyophilized clam; lyophilized fish;
D O I
10.1016/j.talanta.2006.03.025
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Three platinum group elements (Pd, Ir and Rh) both in solution and in pre-reduced form, and also combined with Mg(NO3)(2) or ascorbic acid, were assessed as possible chemical modifiers on the atornization of As in digest solutions of seafood matrices (clam and fish tissue) by tungsten coil electrothermal atomic absorption spectrometry (TCA-AAS) and compared without a modifier. Of 28 modifier alternatives in study including single form and binary mixtures, and based on maximum pyrolysis temperature without significant As loss and best As absorbance sensitivity during atornization, three modifiers: Rh (0.5 mu g), Ir (1.0 mu g) and Rh (0.5 mu g) + ascorbic acid (0.5 mu g), at optimum amounts were pre-selected and compared. The definitive modifier (rhodium (0.5 mu g)) was selected by variance analysis. The mean within-day repeatability was 3% in consecutive measurements (25-300 mu g l(-1)) (three cycles, each of n = 6) and showed good short-term stability of the absorbance measurements. The mean reproducibility was 4% (n = 18 in a 3-day period) and the detection limit (3 sigma(blank)/slope) was 42 pg (n = 16). Quantitation was by standard additions to compensate for matrix effects not corrected by the modifier. Three sample digestion procedures were compared in fish and clam tissue samples: microwave acid digestion alone (A) or combined with the addition of 2% (m/v) K2S2O8 solution followed either by UV photo-oxidation (B) or re-digestion in a thermal block (C). The accuracy was established by determination of As in certified reference material of dogfish muscle (DORM-2). Procedures B and C showed good recoveries (102% (n = 4) and 103% (n = 7), respectively), whereas procedure A was not quantitative (85%). The methodology is simple, fast, reliable, of low cost and was applied to the determination of total As in lyophilized samples of clam and fish collected in the Chilean coast. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:81 / 89
页数:9
相关论文
共 50 条
  • [32] Direct determination of cadmium in Orujo spirit samples by electrothermal atomic absorption spectrometry:: Comparative study of different chemical modifiers
    Farinas, M. Vilar
    Garcia, J. Barciela
    Martin, S. Garcia
    Crecente, R. Pena
    Latorre, C. Herrero
    ANALYTICA CHIMICA ACTA, 2007, 591 (02) : 231 - 238
  • [33] Determination of cadmium in rice and water by tungsten coil electrothermal vaporization-atomic fluorescence spectrometry and tungsten coil electrothermal atomic absorption spectrometry after cloud point extraction
    Wen, Xiaodong
    Wu, Peng
    Chen, Li
    Hou, Xiandeng
    ANALYTICA CHIMICA ACTA, 2009, 650 (01) : 33 - 38
  • [34] Evaluation of different permanent modifiers for the determination of arsenic in environmental samples by electrothermal atomic absorption spectrometry
    Lima, ÉC
    Brasil, JL
    Vaghetti, JCP
    TALANTA, 2003, 60 (01) : 103 - 113
  • [35] Determination of chromium in urine by electrothermal atomic absorption spectrometry using different chemical modifiers
    Burguera, JL
    Burguera, M
    Rondon, C
    Rodríguez, L
    Carrero, P
    de Peña, YP
    Burguera, E
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (05) : 821 - 825
  • [36] CHEMICAL MODIFIERS IN THE DETERMINATION OF MOLYBDENUM IN HUMAN SERUM BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY
    BERMEJOBARRERA, P
    PITACALVO, C
    BERMEJOBARRERA, A
    BERMEJOMARTINEZ, F
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1991, 340 (04): : 265 - 268
  • [37] Platinum group metals as chemical modifiers for the determination of molybdenum by electrothermal atomic absorption spectrometry
    Piperaki, EA
    Thomaidis, NS
    Demis, I
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (12) : 1901 - 1906
  • [38] Comparison of chemical modifiers used for the determination of gold in ores by electrothermal atomic absorption spectrometry
    Gong, BL
    Liu, YM
    Li, JX
    Lin, TZ
    ANALYTICA CHIMICA ACTA, 1998, 362 (2-3) : 247 - 251
  • [40] DETERMINATION OF SELENIUM BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY .1. CHEMICAL MODIFIERS
    DOCEKALOVA, H
    DOCEKAL, B
    KOMAREK, J
    NOVOTNY, I
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (08) : 661 - 668