Primary stability and viscoelastic displacement of mini-implant system under loading

被引:13
|
作者
Lee, Jim [1 ]
Jeong, Yong-Hoon [1 ]
Pittman, Joseph [1 ]
Deguchi, Toru [1 ]
Johnston, William M. [2 ]
Fields, Henry W. [1 ]
Kim, Do-Gyoon [1 ]
机构
[1] Ohio State Univ, Coll Dent, Div Orthodont, 4088 Postle Hall,305 W 12th Ave, Columbus, OH 43210 USA
[2] Ohio State Univ, Coll Dent, Div Gen Practice & Mat Sci, Columbus, OH 43210 USA
关键词
Mini-implant; Diameter; Orthodontic loading; Creep; Bone mineral density; Thickness; ORTHODONTIC MINISCREW IMPLANTS; TISSUE MINERAL DENSITY; CORTICAL BONE; ROOT PROXIMITY; ANCHORAGE; FAILURE; VARIABILITY; STRENGTH; BEHAVIOR; SUCCESS;
D O I
10.1016/j.clinbiomech.2016.11.004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: The objectives of the current study were to examine the effects of mini-implant diameters on 1) primary stability before bone properties are changed by active peri-implant bone remodeling and 2) the time-dependent displacement of mini-implant systems in bone under a functional radial loading and their associations with bone mineral density. Methods: Twenty one, 8 mm length mini-implants (7 each for 1.4 mm, 1.6 mm, and 2 mm diameters) were placed in mandibular sections of human cadavers (4 males and 3 females, average 69.7 (SD 13.1) years of age). Displacement of the mini-implant in wet bone was assessed during initial and subsequent continuous radial loading of 2 N in the mediolateral direction for 2 h. Mean, standard deviation and coefficient of variation of peri-implant bone mineral density were obtained using histograms of cone-beam computed tomography attenuation values. The cortical thickness along with the miniscrew site was also measured. Findings: The primary stability and displacement of mini-implants in bone were not significantly different between the 3 diameter groups (p > 0.147, n = 21). Moderate positive correlations of time-dependent viscoelastic displacement (creep) were found with bone mineral density variability independent of the mini-implant diameters (p > 0.11). Interpretation: The post-implantation displacements of mini-implant suggested that the orthodontic treatment loading can develop micromotion between the mini-implant and surrounding bone leading to reduction of its primary stability. Current findings also provide an insight that peri-implant bone mineral density variability plays an important role in controlling displacement of the mini-implant, which determine its stability during early and prolonged orthodontic treatment loading periods. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:28 / 33
页数:6
相关论文
共 50 条
  • [31] A novel technique for measurement of orthodontic mini-implant stability using the Osstell ISQ device
    Hosein, Yara K.
    Dixon, S. Jeffrey
    Rizkalla, Amin S.
    Tassi, Ali
    ANGLE ORTHODONTIST, 2019, 89 (02) : 284 - 291
  • [32] Impact of mini-implant length on stability at the initial healing period: a controlled clinical study
    Manuel Nienkemper
    Benedict Wilmes
    Alexander Pauls
    Dieter Drescher
    Head & Face Medicine, 9
  • [33] Impact of mini-implant length on stability at the initial healing period: a controlled clinical study
    Nienkemper, Manuel
    Wilmes, Benedict
    Pauls, Alexander
    Drescher, Dieter
    HEAD & FACE MEDICINE, 2013, 9
  • [34] Effect of photobiomodulation therapy on mini-implant stability: a systematic review and meta-analysis
    Bo Zhang
    Xinqi Huang
    Sibei Huo
    Chenghao Zhang
    Xiao Cen
    Zhihe Zhao
    Lasers in Medical Science, 2021, 36 : 1557 - 1566
  • [35] Effect of photobiomodulation therapy on mini-implant stability: a systematic review and meta-analysis
    Zhang, Bo
    Huang, Xinqi
    Huo, Sibei
    Zhang, Chenghao
    Cen, Xiao
    Zhao, Zhihe
    LASERS IN MEDICAL SCIENCE, 2021, 36 (08) : 1557 - 1566
  • [36] Analysis on the stress of the bone surrounding mini-implant with different diameters and lengths under torque
    Lu, Yingjuan
    Chang, Shaohai
    Ye, Jiantao
    Ye, Yushan
    Yu, Yansong
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2015, 26 : S541 - S545
  • [37] The effects of different pilot-drilling methods on the mechanical stability of a mini-implant system at placement and removal: a preliminary study
    Cho, Il-Sik
    Choo, HyeRan
    Kim, Seong-Kyun
    Shin, Yun-Seob
    Kim, Duck-Su
    Kim, Seong-Hun
    Chung, Kyu-Rhim
    Huang, John C.
    KOREAN JOURNAL OF ORTHODONTICS, 2011, 41 (05): : 354 - 360
  • [38] Mini-implant mandibular overdentures under a two-step immediate loading protocol: A 4-6-year retrospective study
    Park, Jin-Hong
    Shin, Sang-Wan
    Lee, Jeong-Yol
    GERODONTOLOGY, 2023, 40 (04) : 501 - 508
  • [39] Distal movement of maxillary molars using a lever-arm and mini-implant system
    Lim, Seung-Min
    Hong, Ryoon-Ki
    ANGLE ORTHODONTIST, 2008, 78 (01) : 167 - 175
  • [40] STABILITY OF A VISCOELASTIC PLATE UNDER DYNAMIC LOADING
    BADALOV, FB
    ESHMATOV, K
    AKBAROV, UI
    SOVIET APPLIED MECHANICS, 1991, 27 (09): : 892 - 899