Primary stability and viscoelastic displacement of mini-implant system under loading

被引:13
|
作者
Lee, Jim [1 ]
Jeong, Yong-Hoon [1 ]
Pittman, Joseph [1 ]
Deguchi, Toru [1 ]
Johnston, William M. [2 ]
Fields, Henry W. [1 ]
Kim, Do-Gyoon [1 ]
机构
[1] Ohio State Univ, Coll Dent, Div Orthodont, 4088 Postle Hall,305 W 12th Ave, Columbus, OH 43210 USA
[2] Ohio State Univ, Coll Dent, Div Gen Practice & Mat Sci, Columbus, OH 43210 USA
关键词
Mini-implant; Diameter; Orthodontic loading; Creep; Bone mineral density; Thickness; ORTHODONTIC MINISCREW IMPLANTS; TISSUE MINERAL DENSITY; CORTICAL BONE; ROOT PROXIMITY; ANCHORAGE; FAILURE; VARIABILITY; STRENGTH; BEHAVIOR; SUCCESS;
D O I
10.1016/j.clinbiomech.2016.11.004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: The objectives of the current study were to examine the effects of mini-implant diameters on 1) primary stability before bone properties are changed by active peri-implant bone remodeling and 2) the time-dependent displacement of mini-implant systems in bone under a functional radial loading and their associations with bone mineral density. Methods: Twenty one, 8 mm length mini-implants (7 each for 1.4 mm, 1.6 mm, and 2 mm diameters) were placed in mandibular sections of human cadavers (4 males and 3 females, average 69.7 (SD 13.1) years of age). Displacement of the mini-implant in wet bone was assessed during initial and subsequent continuous radial loading of 2 N in the mediolateral direction for 2 h. Mean, standard deviation and coefficient of variation of peri-implant bone mineral density were obtained using histograms of cone-beam computed tomography attenuation values. The cortical thickness along with the miniscrew site was also measured. Findings: The primary stability and displacement of mini-implants in bone were not significantly different between the 3 diameter groups (p > 0.147, n = 21). Moderate positive correlations of time-dependent viscoelastic displacement (creep) were found with bone mineral density variability independent of the mini-implant diameters (p > 0.11). Interpretation: The post-implantation displacements of mini-implant suggested that the orthodontic treatment loading can develop micromotion between the mini-implant and surrounding bone leading to reduction of its primary stability. Current findings also provide an insight that peri-implant bone mineral density variability plays an important role in controlling displacement of the mini-implant, which determine its stability during early and prolonged orthodontic treatment loading periods. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:28 / 33
页数:6
相关论文
共 50 条
  • [1] Systematic review of mini-implant displacement under orthodontic loading
    Manuel Nienkemper
    Jörg Handschel
    Dieter Drescher
    International Journal of Oral Science, 2014, 6 : 1 - 6
  • [2] Systematic review of mini-implant displacement under orthodontic loading
    Nienkemper, Manuel
    Handschel, Joerg
    Drescher, Dieter
    INTERNATIONAL JOURNAL OF ORAL SCIENCE, 2014, 6 (01) : 1 - 6
  • [3] Systematic review of mini-implant displacement under orthodontic loading
    Manuel Nienkemper
    Jrg Handschel
    Dieter Drescher
    International Journal of Oral Science, 2014, 6 (01) : 1 - 6
  • [4] Systematic review of mini-implant displacement under orthodontic loading
    Manuel Nienkemper
    Jrg Handschel
    Dieter Drescher
    International Journal of Oral Science, 2014, (01) : 1 - 6
  • [5] Primary migration of a mini-implant under a functional orthodontic loading
    Pittman, Joseph W.
    Navalgund, Anand
    Byun, Steve H.
    Huang, Hechang
    Kim, Albert H.
    Kim, Do-Gyoon
    CLINICAL ORAL INVESTIGATIONS, 2014, 18 (03) : 721 - 728
  • [6] Primary migration of a mini-implant under a functional orthodontic loading
    Joseph W. Pittman
    Anand Navalgund
    Steve H. Byun
    Hechang Huang
    Albert H. Kim
    Do-Gyoon Kim
    Clinical Oral Investigations, 2014, 18 : 721 - 728
  • [7] The effect of loading time on the stability of mini-implant
    Lee, Seung-Yeon
    Cha, Jung-Yul
    Yoon, Tae-min
    Park, Young-Chel
    KOREAN JOURNAL OF ORTHODONTICS, 2008, 38 (03): : 149 - 158
  • [8] Effect of mini-implant length and diameter on primary stability under loading with two force levels
    Chatzigianni, Athina
    Keilig, Ludger
    Reimann, Susanne
    Eliades, Theodore
    Bourauel, Christoph
    EUROPEAN JOURNAL OF ORTHODONTICS, 2011, 33 (04) : 381 - 387
  • [9] Orthodontic Mini-Implant Stability under Continuous or Intermittent Loading: A Histomorphometric and Biomechanical Analysis
    Wu, Yeke
    Xu, Zhenrui
    Tan, Luyuan
    Tan, Lijun
    Zhao, Zhihe
    Yang, Pu
    Li, Yu
    Tang, Tian
    Zhao, Lixing
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 (01) : 163 - 172
  • [10] Root and Bone Response to the Proximity of a Mini-Implant under Orthodontic Loading
    Lee, Yang-Ku
    Kim, Jong-Wan
    Baek, Seung-Hak
    Kim, Tae-Woo
    Chang, Young-Il
    ANGLE ORTHODONTIST, 2010, 80 (03) : 452 - 458