Inverted Pulse Estimation in Pulse Inversion Harmonic Imaging using Deep Learning

被引:0
|
作者
Fouad, Mariam [1 ]
Schmitz, Georg [1 ]
机构
[1] Ruhr Univ Bochum, Chair Med Engn, Bochum, Germany
关键词
deep learning; convolutional autoencoders; harmonic imaging; pulse inversion; nonlinear propagation;
D O I
10.1109/IUS54386.2022.9958113
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Conventional methods such as filtering and multi-pulse acquisition techniques play an important role in ultrasonic nonlinear imaging, specifically harmonic imaging. However, the former suffers from spectral leakage, while the latter is hindered by the low frame rate and increased susceptibility to motion artifacts caused by the need to transmit two or more pulses. In this work, deep learning concepts are exploited to achieve a single-shot harmonic imaging application. This is accomplished by implementing an asymmetric convolutional autoencoder, capable of learning the nonlinear relationship between the echo resulting from the first transmitted pulse (network input) and the echo resulting from the second transmitted (inverted) pulse (network output) used in the conventional pulse inversion technique. The proposed approach yielded harmonic images with comparable contrast to noise and contrast ratios to the conventional pulse inversion technique, yet at approximately double the frame rate. These findings pave the way for harmonic imaging to be used with quality that is on par with the quality achieved by current harmonic imaging methods but with a higher framerate and fewer motion artifacts.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] EVALUATION OF PULSE ESTIMATION AND SEISMIC TRACE INVERSION PROCEDURES
    BRANISA, F
    NIKOLIC, ZJ
    [J]. GEOPHYSICS, 1982, 47 (07) : 1118 - 1118
  • [42] EVALUATION OF PULSE ESTIMATION AND SEISMIC TRACE INVERSION PROCEDURES
    BRANISA, F
    NIKOLIC, ZJ
    [J]. GEOPHYSICS, 1982, 47 (04) : 472 - 472
  • [43] Single Attosecond Pulse Generation Using a Seed Harmonic Pulse Train
    Ishikawa, Kenichi L.
    Takahashi, Eiji J.
    Midorikawa, Katsumi
    [J]. 2007 CONFERENCE ON LASERS & ELECTRO-OPTICS/QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE (CLEO/QELS 2007), VOLS 1-5, 2007, : 2083 - +
  • [44] Characterization of unifocal liver lesions with pulse inversion harmonic imaging after Levovist injection: preliminary results
    M. Bertolotto
    L. Dalla Palma
    E. Quaia
    M. Locatelli
    [J]. European Radiology, 2000, 10 : 1369 - 1376
  • [45] Contrast-enhanced ultrasound imaging using pulse inversion spectral deconvolution
    Khairalseed, Mawia
    Oezdemir, Ipek
    Hoyt, Kenneth
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2019, 146 (04): : 2466 - 2474
  • [46] Pulse-inversion harmonic imaging improves lesion conspicuity during US-guided biopsy
    Meuwly, JY
    Schnyder, P
    Gudinchet, F
    Denys, AL
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2003, 14 (03) : 335 - 341
  • [47] Potential Contrast Improvement in Ultrasound Pulse Inversion Imaging Using EMD and EEMD
    Liao, Ai-Ho
    Shen, Che-Chou
    Li, Pai-Chi
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2010, 57 (02) : 317 - 326
  • [48] Characterization of unifocal liver lesions with pulse inversion harmonic imaging after Levovist injection: preliminary results
    Bertolotto, M
    Dalla Palma, L
    Quaia, E
    Locatelli, M
    [J]. EUROPEAN RADIOLOGY, 2000, 10 (09) : 1369 - 1376
  • [49] Comparing Levovist-Enhanced pulse inversion harmonic imaging and ferumoxides-enhanced MR imaging of hepatic metastases
    Del Frate, C
    Zuiani, C
    Londero, V
    Como, G
    Bazzocchi, M
    Mortele, K
    Pablo, R
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 180 (05) : 1339 - 1346
  • [50] Deep Learning for Radar Pulse Detection
    Nguyen, Ha Q.
    Ngo, Dat T.
    Van Long DO
    [J]. ICPRAM: PROCEEDINGS OF THE 8TH INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION APPLICATIONS AND METHODS, 2019, : 32 - 39