A Particle Model for Prediction of Cement Infiltration of Cancellous Bone in Osteoporotic Bone Augmentation

被引:15
|
作者
Basafa, Ehsan [1 ,2 ]
Murphy, Ryan J. [1 ,2 ,3 ]
Kutzer, Michael D. [3 ]
Otake, Yoshito [2 ]
Armand, Mehran [1 ,2 ,3 ,4 ]
机构
[1] Johns Hopkins Univ, Dept Mech Engn, Baltimore, MD 21218 USA
[2] Johns Hopkins Univ, Lab Computat Sensing & Robot, Baltimore, MD USA
[3] Johns Hopkins Univ, Appl Phys Lab, Laurel, MD USA
[4] Johns Hopkins Univ, Dept Orthopaed Surg, Baltimore, MD USA
来源
PLOS ONE | 2013年 / 8卷 / 06期
基金
美国国家卫生研究院;
关键词
MECHANICAL-PROPERTIES; PROXIMAL FEMUR; FLOW; POLYMETHYLMETHACRYLATE; FEMOROPLASTY; FLUID; SPH; HYDRODYNAMICS; INJECTION; PERMEABILITY;
D O I
10.1371/journal.pone.0067958
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Femoroplasty is a potential preventive treatment for osteoporotic hip fractures. It involves augmenting mechanical properties of the femur by injecting Polymethylmethacrylate (PMMA) bone cement. To reduce the risks involved and maximize the outcome, however, the procedure needs to be carefully planned and executed. An important part of the planning system is predicting infiltration of cement into the porous medium of cancellous bone. We used the method of Smoothed Particle Hydrodynamics (SPH) to model the flow of PMMA inside porous media. We modified the standard formulation of SPH to incorporate the extreme viscosities associated with bone cement. Darcy creeping flow of fluids through isotropic porous media was simulated and the results were compared with those reported in the literature. Further validation involved injecting PMMA cement inside porous foam blocks - osteoporotic cancellous bone surrogates - and simulating the injections using our proposed SPH model. Millimeter accuracy was obtained in comparing the simulated and actual cement shapes. Also, strong correlations were found between the simulated and the experimental data of spreading distance (R-2=0.86) and normalized pressure (R-2=0.90). Results suggest that the proposed model is suitable for use in an osteoporotic femoral augmentation planning framework.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Multiphasic modelling of bone-cement injection into vertebral cancellous bone
    Bleiler, Christian
    Wagner, Arndt
    Stadelmann, Vincent A.
    Windolf, Markus
    Koestler, Harald
    Boger, Andreas
    Gueorguiev-Rueegg, Boyko
    Ehlers, Wolfgang
    Roehrle, Oliver
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2015, 31 (01) : 37 - 57
  • [32] Osteoporotic Bone: When and How to Use Augmentation?
    Schuetze, Konrad
    Eickhoff, Alexander
    Roederer, Goetz
    Gebhard, Florian
    Richter, Peter H.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2019, 33 : S21 - S26
  • [33] The Efficacy of Demineralized Bone Matrix and Cancellous Bone Chips for Maxillary Sinus Augmentation
    Kim, David M.
    Nevins, Marc L.
    Camelo, Marcelo
    Borges Camelo, Joao Marcelo
    Schupbach, Peter
    Hanratty, James J.
    Utzel, N. Guzin
    Nevins, Myron
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2009, 29 (04) : 415 - 424
  • [34] VARIABLES RELATED TO MG CONTENT OF HEALTHY AND OSTEOPOROTIC CANCELLOUS BONE
    KNUUTTILA, M
    LAPPALAINEN, R
    ALHAVA, E
    OLKKONEN, H
    LAMMI, S
    JOURNAL OF DENTAL RESEARCH, 1981, 60 : 451 - 451
  • [35] The benefits of cement augmentation of pedicle screw fixation are increased in Osteoporotic bone: A finite element analysis
    Wang W.
    Baran G.R.
    Garg H.
    Betz R.R.
    Moumene M.
    Cahill P.J.
    Spine Deformity, 2014, 2 (4) : 248 - 259
  • [36] Damage initiation sites in osteoporotic and normal human cancellous bone
    Soicher, Matthew A.
    Wang, Xiang
    Zauel, Roger R.
    Fyhrie, David P.
    BONE, 2011, 48 (03) : 663 - 666
  • [37] The Biomechanical Properties of Pedicle Screw Fixation Combined With Trajectory Bone Cement Augmentation in Osteoporotic Vertebrae
    Fan, Haitao T.
    Zhang, Renjie J.
    Shen, Cailiang L.
    Dong, Fulong L.
    Li, Yong
    Song, Peiwen W.
    Gong, Chen
    Wang, Yijin J.
    CLINICAL SPINE SURGERY, 2016, 29 (02): : 78 - 85
  • [38] Variation of the mechanical properties of PMMA to suit osteoporotic cancellous bone
    Boger, Andreas
    Bisig, Adrian
    Bohner, Marc
    Heini, Paul
    Schneider, Erich
    JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2008, 19 (09) : 1125 - 1142
  • [39] Causes of Late Revision Surgery after Bone Cement Augmentation in Osteoporotic Vertebral Compression Fractures
    Ha, Kee-Yong
    Kim, Young-Hoon
    Chang, Dong-Gunn
    Son, Il-Nam
    Kim, Ki-Won
    Kim, Sung-Eun
    ASIAN SPINE JOURNAL, 2013, 7 (04) : 294 - 300
  • [40] Quantification of interdigitation at bone cement/cancellous bone interfaces in cemented femoral reconstructions
    Maher, SA
    McCormack, BAO
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1999, 213 (H4) : 347 - 354