Using Transient Elastography to Detect Chronic Liver Diseases in a Primary Care Nurse Consultancy

被引:23
|
作者
Fabrellas, Nuria [1 ]
Alemany, Magda [2 ]
Urquizu, Marta [2 ]
Bartres, Concepcio [3 ]
Pera, Guillem [4 ,5 ]
Juve, Eulalia [6 ,7 ]
Rodriguez, Lluis [8 ]
Toran, Pere [9 ]
Caballeria, Llorenc [10 ]
机构
[1] Univ Barcelona, Sch Nursing, Inst Invest Biomed Bellvitge IDIBELL, Barcelona, Catalonia, Spain
[2] Inst Univ Invest Atencio Primaria Jordi Gol IDIAP, Unitat Suport Recerca Metropolitana Nord, Santa Coloma De Gramenet, Spain
[3] Hosp Clin Barcelona, Unitat Func Hepatitis, Liver Unit, Barcelona, Catalonia, Spain
[4] Inst Univ Invest Atencio Primaria Jordi Gol IDIAP, Unitat Suport Recerca Metropolitana Nord, Res Support Unit, Santa Coloma De Gramenet, Spain
[5] Ctr Invest Biomed Red Enfermedades Hepat & Digest, Barcelona, Catalonia, Spain
[6] Univ Barcelona, Sch Nursing, IDIBELL, Barcelona, Catalonia, Spain
[7] Inst Catala Salut, Catalonia, Spain
[8] IDIAP Jordi Gol, Unitat Suport Recerca Metropolitana Nord, Santa Coloma De Gramenet, Spain
[9] IDIAP Jordi Gol, Unitat Suport Recerca Metropolitana Nord, Res Support Unit, Santa Coloma De Gramenet, Spain
[10] IDIAP Jordi Gol, Unitat Suport Recerca Metropolitana Nord, Res Unit Liver Dis, Santa Coloma De Gramenet, Spain
关键词
chronic liver diseases; nursing intervention; primary care; transient elastography; FATTY LIVER; NONINVASIVE ASSESSMENT; FIBROSIS; PERFORMANCE; POPULATION; CIRRHOSIS; RISK;
D O I
10.1097/NNR.0000000000000001
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Background: Chronic liver diseases (CLDs) are significant causes of death in adults in many countries and are usually diagnosed at late stages. Early detection may allow time for treatment to prevent disease progression. Objectives: The aim of this study was to assess the feasibility of screening for unrecognized CLDs in a primary care nurse consultancy and report findings from screening. Methods: Two experienced nurses in a primary care nurse consultancy were trained to perform transient elastography (TE). Subjects aged from 18 to 70 years were identified randomly from the health registry and invited to participate in a feasibility pilot study. Exclusion criteria were past or current history of liver diseases. Nurses collected demographic and clinical data and performed TE tests using Fibroscan to measure liver stiffness; a cutoff score of 6.8 kPa or greater was used as an indicator of the presence of CLD with fibrosis. Results: Accurate measurements were obtained in 495 of 502 participants (98.6%). Prevalence of elevated liver stiffness was observed in 28 of 495 subjects (5.7%). Compared to patients with normal liver stiffness, patients with increased liver stiffness were older, were more frequently male, and had higher frequency of metabolic syndrome. Nonalcoholic fatty liver was the most common cause of CLD. Discussion: Following training in procedures for conducting TE, nurses in a primary care clinic were able to detect unrecognized CLDs in presumably healthy subjects. Early detection of CLDs is feasible in primary care clinics and may facilitate identification of undiagnosed CLD in adults.
引用
收藏
页码:450 / 454
页数:5
相关论文
共 50 条
  • [31] Steatosis and Liver Stiffness Measurements Using Transient Elastography
    Eddowes, Peter
    Sasso, Magali
    Fournier, Celine
    Vuppalanchi, Raj
    Newsome, Philip N.
    HEPATOLOGY, 2016, 64 (02) : 700 - 700
  • [32] Detection of liver injury in IBD using transient elastography
    Thin, L. W. Y.
    Lawrance, I. C.
    Spilsbury, K.
    Kava, J.
    Olynyk, J. K.
    JOURNAL OF CROHNS & COLITIS, 2014, 8 (07): : 671 - 677
  • [33] Comparison of Visual Transient Elastography and Shear Wave Elastography in Evaluating Liver Fibrosis in Patients with Chronic Liver Disease
    Yang, Jiali
    Li, Jiawu
    Ye, Guilin
    Luo, Yan
    INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2021, 14 : 3553 - 3561
  • [34] COMPARISON OF SOUND TOUCH ELASTOGRAPHY, SHEAR WAVE ELASTOGRAPHY AND VIBRATION-CONTROLLED TRANSIENT ELASTOGRAPHY IN CHRONIC LIVER DISEASE ASSESSMENT USING LIVER BIOPSY AS THE "REFERENCE STANDARD"
    Gatos, Ilias
    Drazinos, Petros
    Yarmenitis, Spyros
    Theotokas, Ioannis
    Zoumpoulis, Pavlos S.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2020, 46 (04): : 959 - 971
  • [35] Interobserver discrepancy in liver fibrosis using transient elastography
    Roca, B.
    Resino, E.
    Torres, V.
    Herrero, E.
    Penades, M.
    JOURNAL OF VIRAL HEPATITIS, 2012, 19 (10) : 711 - 715
  • [36] Evaluation of liver fibrosis in diabetes using transient elastography
    Kwok, R.
    Girgis, C.
    Chen, R.
    Ngu, M. C.
    Lee, A. U.
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2009, 24 : A283 - A283
  • [37] Clinical application of liver stiffness measurement using transient elastography in chronic liver disease from longitudinal perspectives
    Beom Kyung Kim
    James Fung
    Man-Fung Yuen
    Seung Up Kim
    World Journal of Gastroenterology, 2013, 19 (12) : 1890 - 1900
  • [38] Overestimation of liver fibrosis staging using transient elastography in patients with chronic hepatitis C and significant liver inflammation
    Vispo, Eugenia
    Barreiro, Pablo
    del Valle, Jose
    Maida, Ivana
    de Ledinghen, Victor
    Quereda, Carmen
    Moreno, Alberto
    Macias, Juan
    Castera, Laurent
    Antonio Pineda, Juan
    Soriano, Vincent
    ANTIVIRAL THERAPY, 2009, 14 (02) : 187 - 193
  • [39] Longitudinal Assessment of Liver Fibrosis By Liver Stiffness Measurements Using Transient Elastography in Chronic Hepatitis B Patients
    Chi, Heng
    Hansen, Bettina E.
    Buster, Erik H.
    de Knegt, Robert J.
    Janssen, Harry L.
    HEPATOLOGY, 2013, 58 : 718A - 718A
  • [40] Advances in liver stiffness measurements using transient elastography
    Sandrin, Laurent
    Miette, Veronique
    Yon, Sylvain
    Fournier, Celine
    2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 2271 - 2274