Evaluation of the organs at risk doses for lung tumors in gated and conventional radiotherapy

被引:1
|
作者
Shahzadeh, Sara [1 ]
Gholami, Somayeh [2 ]
Mahmood, Seyed [1 ]
Aghamiri, Reza [1 ]
Mahani, Hojjat [3 ]
Nabavi, Mansoure [2 ]
机构
[1] Shahid Beheshti Univ, Dept Med Radiat Engn, Tehran, Iran
[2] Univ Tehran Med Sci, Radiotherapy Oncol Res Ctr, Canc Inst, Keshavarz Blvd, Tehran 141556447, Iran
[3] Univ Tehran Med Sci, Res Ctr Mol & Cellular Imaging, Tehran, Iran
关键词
Four-dimensional-extended cardiac-torso phantom; gated RT; organs at risk doses; 4D XCAT PHANTOM; REAL-TIME TUMOR; TRACKING RADIOTHERAPY; RESPIRATORY MOTION; MANAGEMENT;
D O I
10.4103/jcrt.JCRT_735_18
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The purpose of this study was to evaluate the organs at risk (OARs) doses for lung tumors in gated radiotherapy (RT) compared to conventional RT using the four-dimensional extended cardiac-torso (4D-XCAT) digital phantom in a simulation study. Materials and Methods: 4D-XCAT digital phantom was used to create 32 digital phantom datasets of different tumor diameters of 3 and 4 cm, and motion ranges (MRs) of 2, 2.5, 3, and 3.5 cm and each tumor was placed in four different lung locations (right lower lobe, right upper lobe, left lower lobe, and left upper lobe). XCAT raw binary images were converted to the digital imaging and communication in medicine format using an in-house MATLAB-based program and were imported to treatment planning system (TPS). For each dataset, gated and conventional treatment plans were prepared using Planning Computerized RadioTherapy-three dimensional (PCRT-3D) TPS with superposition computational algorithm. Dose differences between gated and conventional plans were evaluated and compared (as a function of 3D motion and tumor volume and its location) with respect to the dose-volume histograms of different organs-at-risk. Results: There are statistically significant differences in dosimetric parameters among gated and conventional RT, especially for the tumors near the diaphragm (P < 0.05). The maximum reduction in the mean dose of the lung, heart, and liver were 6.11 Gy, 1.51 Gy, and 10.49 Gy, respectively, using gated RT. Conclusions: Dosimetric comparison between gated and conventional RT showed that gated RT provides relevant dosimetric improvements to lung normal tissue and the other OARs, especially for the tumors near the diaphragm. In addition, dosimetric differences between gated and conventional RT did generally increase with increasing tumor motion and decreasing tumor volume.
引用
收藏
页码:726 / 730
页数:5
相关论文
共 50 条
  • [31] Respiratory Gated Radiation Therapy With Hypofractionated Doses for Lung Tumors: Four Years' Experience of a Single Institution
    Almaghrabi, M. Y.
    Mahe, M.
    Rio, E.
    Bardet, E.
    Thillays, F.
    Lisbona, A.
    Gaudaire-Josset, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S863 - S863
  • [32] Are three doses of stereotactic ablative radiotherapy (SABR) more effective than 30 doses of conventional radiotherapy?
    Simeonova, Anna O.
    Fleckenstein, Katharina
    Wertz, Hansjorg
    Frauenfeld, Anian
    Boda-Heggemann, Judit
    Lohr, Frank
    Wenz, Frederik
    TRANSLATIONAL LUNG CANCER RESEARCH, 2012, 1 (01) : 45 - 53
  • [33] An analysis of planned versus delivered airway doses during stereotactic lung radiotherapy for central tumors
    Dahele, Max
    de Koste, John R. van Soernsen
    Verbakel, Wilko F.
    Slotman, Ben J.
    Senan, Suresh
    ACTA ONCOLOGICA, 2016, 55 (07) : 934 - 937
  • [34] RADIOTHERAPY OF PAEDIATRIC BRAIN LESIONS: DETERMINATION OF DOSES TO UNTARGETED ORGANS
    Taylor, M.
    Kron, T.
    Franich, F.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S372 - S372
  • [35] PREDICTED ALLOWABLE DOSES TO NORMAL ORGANS FOR BIOLOGICALLY TARGETED RADIOTHERAPY
    ODONOGHUE, JA
    WHELDON, TE
    BRITISH JOURNAL OF RADIOLOGY, 1988, 61 (723): : 264 - 266
  • [36] Doses in organs at risk during head and neck radiotherapy using IMRT and 3D-CRT
    Peszynska-Piorun, Magdalena
    Malicki, Julian
    Golusinski, Wojciech
    RADIOLOGY AND ONCOLOGY, 2012, 46 (04) : 328 - 336
  • [37] On effective dose for radiotherapy based on doses to nontarget organs and tissues
    Uselmann, Adam J.
    Thomadsen, Bruce R.
    MEDICAL PHYSICS, 2015, 42 (02) : 977 - 982
  • [38] Extracranial doses in stereotactic and conventional radiotherapy for pituitary adenomas
    Ram, Thomas Samuel
    Ravindran, Paul B.
    Viswanathan, Faith R.
    Viswanathan, Perungulam Narayan
    Pavamani, Simon P.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2006, 7 (02): : 96 - 100
  • [39] Dosimetric evaluation of gated rotational radiotherapy
    Falk, M.
    Kjaer-Kristoffersen, F.
    Bangsgaard, J. P.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S223 - S224
  • [40] Interactive contour delineation of organs at risk in radiotherapy: Clinical evaluation on NSCLC patients
    Dolz, J.
    Kirisli, H. A.
    Fechter, T.
    Karnitzki, S.
    Oehlke, O.
    Nestle, U.
    Vermandel, M.
    Massoptier, L.
    MEDICAL PHYSICS, 2016, 43 (05) : 2569 - 2580