Improvements in an in vivo neutron activation analysis (NAA) method for the measurement of fluorine in human bone

被引:16
|
作者
Mostafaei, F. [1 ]
McNeill, F. E. [1 ]
Chettle, D. R. [1 ]
Prestwich, W. V. [1 ]
机构
[1] McMaster Univ, Hamilton, ON L8S 4K1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
in vivo; neutron activation analysis; fluorine; bone; QUANTIFICATION; PHANTOM; CAVITY; HAND;
D O I
10.1088/0967-3334/34/10/1329
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We previously published a method for the in vivo measurement of bone fluoride using neutron activation analysis (NAA) and demonstrated the utility of the technique in a pilot study of environmentally exposed people. The method involved activation of the hand in an irradiation cavity at the McMaster University Accelerator Laboratory and acquisition of the resultant gamma-ray signals in a '4p' NaI(Tl) detector array of nine detectors. In this paper we describe a series of improvements to the method. This was investigated via measurement of hand simulating phantoms doped with varying levels of fluorine and fixed amounts of sodium, chlorine and calcium. Four improvements to the technique were tested since our first publication. The previously published detection limit for phantom measurements using this system was 0.66 mg F/g Ca. The accelerator irradiation and detection facilities were relocated to a new section of the laboratory and one more detector was added to the detection system. This was found to reduce the detection limit (possibly because of better detection shielding and additional detector) to 0.59 mg F/g Ca, a factor of 1.12. A new set of phantoms was developed and in this work we show that they improved the minimum detectable limit for fluoride in phantoms irradiated using neutrons produced by 2.15 MeV protons on lithium by a factor of 1.55. We compared the detection limits previously obtained using a summed signal from the nine detectors with the detection limit obtained by acquiring the spectra in anticoincidence mode for reduction of the disturbing signal from chlorine in bone. This was found to improve the ratio of the detection of fluorine to chlorine (an interfering signal) by a factor of 2.8 and the resultant minimum detection limit was found to be reduced by a factor of 1.2. We studied the effects of changing the timing of gamma-ray acquisition. Our previously published data used a series of three 10 s acquisitions followed by a 300 s count. Changing the acquisition to a series of six 5 s acquisitions was found to further improve the detection limit by a factor of 1.4. We also present data showing that if the neutron dose is delivered to the phantom in a shorter time period, i.e. the dose rate is increased and irradiation shortened then the detection limit can be reduced by a further factor of 1.35. The overall improvement in detection limit by employing all of these changes was found to be a factor of 3.9. The technique now has an in phantom detection limit of 0.17 mg F/g Ca compared to a previous detection limit of 0.66 mg F/g Ca. The system can now be tested on human volunteers to see if individuals with diagnosed fluorosis can be distinguished from the general Canadian population using this technique.
引用
收藏
页码:1329 / 1341
页数:13
相关论文
共 50 条
  • [41] IN VIVO NEUTRON ACTIVATION ANALYSIS - TECHNIQUE AND ACTIVATION WITH NEUTRONS
    BATTYE, CK
    OSBORN, SB
    SMITH, JW
    BRITISH JOURNAL OF RADIOLOGY, 1965, 38 (454): : 806 - &
  • [42] MEASUREMENT OF CADMIUM IN HUMAN LIVER BY INVIVO NEUTRON-ACTIVATION ANALYSIS
    MCLELLAN, J
    THOMAS, BJ
    FREMLIN, JH
    HARVEY, TC
    CLINICAL SCIENCE AND MOLECULAR MEDICINE, 1974, 47 (05): : P21 - P21
  • [43] Customized compact neutron activation analysis system to quantify manganese (Mn) in bone in vivo
    Liu, Yingzi
    Mostafaei, Farshad
    Sowers, Daniel
    Hsieh, Mindy
    Zheng, Wei
    Nie, Linda H.
    PHYSIOLOGICAL MEASUREMENT, 2017, 38 (03) : 452 - 465
  • [44] Instrumental neutron activation analysis of ferromanganese oxide encrustations of Indian Ocean by the k0 NAA method
    R. K. Dutta
    R. N. Acharya
    V. Chakravortty
    A. G. C. Nair
    A. V. R. Reddy
    S. N. Chintalapudi
    S. B. Manohar
    Journal of Radioanalytical and Nuclear Chemistry, 1998, 237 : 91 - 96
  • [45] Instrumental neutron activation analysis of ferromanganese oxide encrustations of Indian Ocean by the k0 NAA method
    Dutta, RK
    Acharya, RN
    Chakravortty, V
    Nair, AGC
    Reddy, AVR
    Chintalapudi, SN
    Manohar, SB
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1998, 237 (1-2) : 91 - 96
  • [46] Measurement of the neutron spectrum using the activation method
    Jovancevic, N.
    Daraban, L.
    Oberstedt, S.
    Hambsch, F. -J.
    Hult, M.
    Lutter, G.
    Marissens, G.
    GAMMA-2 SCIENTIFIC WORKSHOP ON THE EMISSION OF PROMPT GAMMA-RAYS IN FISSION AND RELATED TOPICS, 2014, 59 : 154 - 159
  • [47] Determination of fluorine in coral skeletons by instrumental neutron activation analysis
    Ramos, AA
    Ohde, S
    Hossain, MMM
    Ozaki, H
    Sirirattanachai, S
    Apurado, JL
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2005, 266 (01) : 19 - 29
  • [48] FLUORINE MICRODETERMINATION BY NEUTRON ACTIVATION ANALYSIS - APPLICATION TO BACTERIOLOGICAL MEDIA
    FELDMAN, MH
    BATTISTO.GC
    JOURNAL OF NUCLEAR MEDICINE, 1966, 7 (02) : 140 - &
  • [49] Determination of fluorine in coral skeletons by instrumental neutron activation analysis
    A. A. Ramos
    S. Ohde
    M. M. M. Hossain
    H. Ozaki
    S. Sirirattanachai
    J. L. Apurado
    Journal of Radioanalytical and Nuclear Chemistry, 2005, 266 : 19 - 29