The Carpentier-Edwards Classic and Physio Annuloplasty Rings in Repair of Degenerative Mitral Valve Disease: A Retrospective Study

被引:3
|
作者
Sidiki, Abubakari, I [1 ]
Faybushevich, Alexandr G. [2 ]
Lishchuk, Alexandr N. [3 ]
Koltunov, Alexandr N. [3 ]
Roshchina, Ekaterina A. [1 ]
机构
[1] Peoples Friendship Univ Russia, Dept Cardiothorac Surg, RUDN Univ, Moscow, Russia
[2] Peoples Friendship Univ Russia, Dept Surg, RUDN Univ, Moscow, Russia
[3] FSBI 3 Cent Vishnevsky Mil Hosp, Cardiovasc Ctr, Moscow, Russia
关键词
Degenerative mitral valve disease; Mitral valve repair; Mitral regurgitation; Rigid ring; Semi-rigid ring; REGURGITATION; OUTCOMES; RECONSTRUCTION; OBSTRUCTION; ANTERIOR;
D O I
10.37616/2212-5043.1027
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Physio ring (SR) is considered an improved version of the Classic rigid ring (RR). Today, SR is more widely used in mitral valve (MV) repair. We sought to compare the long-term outcomes of repair with RR and SR in degenerative mitral valve disease. Methods: In a computerized registry of our institution, 306 patients had MV repair with either RR (139 patients) or SR (167 patients) ring between 2005 and 2015. Fifteen of them had concomitant tricuspid valve repair. Ninety-two (30.1%) had Barlow's disease and 214 (69.9%) had fibroelastic deficiency. The patients had similar demographic and echocardiographic characteristics. Results: There were 4 (1.3%) operative mortalities. Mean follow-up time was 107.4 +/- 13.2 months. Left ventricular end diastolic and end systolic diameters significantly improved in both groups but not between groups. Survival at 10 years was 84.6% (93.1% in RR and 91.5% in SR; p = 0.177) and 10-year freedom from recurrent MR >= 2+ was 74.5% (88.2% in RR and 86.3% in SR; p = 0.110). Reoperations for repair failure were 8 in RR and 6 in SR. By Cox regression analysis, Barlow's disease and preoperative MR = 4+ were predictors of repair failure. Old age (>= 70 years), NYHA functional class IV and pulmonary artery systolic pressure (>= 40 mmHg) were predictors of poor survival by univariate analysis. Conclusion: Long-term outcomes of repair for degenerative MV disease with the Classic and Physio rings are comparable. We also reiterate the importance of large size annuloplasty rings for Barlow's disease to avoid the incidence left ventricular outflow obstruction.
引用
收藏
页码:224 / 232
页数:9
相关论文
共 50 条
  • [1] Mitral valve repair by Carpentier-Edwards physio annuloplasty ring.
    Kurosawa H.
    Nakano M.
    Kawase M.
    Kasegawa H.
    Nakano K.
    Eishi K.
    [J]. The Japanese Journal of Thoracic and Cardiovascular Surgery, 1999, 47 (8): : 355 - 360
  • [2] Initial experience of mitral valve repair using the Carpentier-Edwards Physio II annuloplasty ring
    Vohra, Hunaid A.
    Whistance, Robert N.
    Bezuska, Laurynas
    Livesey, Steve A.
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2011, 39 (06) : 881 - 885
  • [3] Midterm results of mitral valve repair with the Carpentier-Edwards rigid ring
    Sakamoto Y.
    Hashimoto K.
    Okuyama H.
    Ishii S.
    Taguchi S.
    Kagawa H.
    Yoshitake M.
    [J]. The Japanese Journal of Thoracic and Cardiovascular Surgery, 2006, 54 (2) : 56 - 60
  • [4] Mitral valve annuloplasty: Comparison of the mural annulus shortening suture (MASS) with the Carpentier-Edwards prosthetic ring
    Detter, C
    Aybek, T
    Kupilik, N
    Fischlein, T
    Moritz, A
    [J]. JOURNAL OF HEART VALVE DISEASE, 2000, 9 (04): : 478 - 486
  • [5] WHIPPLES DISEASE IN THE PORCINE LEAFLETS OF A CARPENTIER-EDWARDS PROSTHETIC MITRAL-VALVE
    RATLIFF, NB
    MCMAHON, JT
    NAAB, TJ
    COSGROVE, DM
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1984, 311 (14): : 902 - 903
  • [6] Comparison of the novel Medtentia double helix mitral annuloplasty system with the Carpentier-Edwards Physio annuloplasty ring: morphological and functional long-term outcome in a mitral valve insufficiency sheep model
    Konerding, Moritz A.
    Simpanen, Jarmo
    Ihlberg, Leo
    Aittomaeki, Juha
    Werkkala, Kalervo
    Delventhal, Vera
    Ackermann, Maximilian
    [J]. JOURNAL OF CARDIOTHORACIC SURGERY, 2013, 8
  • [7] Comparison of the novel Medtentia double helix mitral annuloplasty system with the Carpentier-Edwards Physio annuloplasty ring: morphological and functional long-term outcome in a mitral valve insufficiency sheep model
    Moritz A Konerding
    Jarmo Simpanen
    Leo Ihlberg
    Juha Aittomäki
    Kalervo Werkkala
    Vera Delventhal
    Maximilian Ackermann
    [J]. Journal of Cardiothoracic Surgery, 8
  • [8] Long-term outcomes after mitral ring annuloplasty for degenerative mitral regurgitation: Duran ring versus carpentier-edwards ring
    Chung, Cheol Hyun
    Kim, Joon Bum
    Choo, Suk Jung
    Kim, Kyung Sun
    Song, Hyun
    Song, Meong Gun
    Song, Jae-Kwan
    Kang, Duk-Hyun
    Lee, Jae Won
    [J]. JOURNAL OF HEART VALVE DISEASE, 2007, 16 (05): : 536 - 544
  • [9] Early calcification of a Carpentier-Edwards Perimount mitral valve in an elderly woman
    Polo, ML
    Legarra, JJ
    Vilar, M
    Cabrera, A
    Durán, D
    Pradas, G
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 124 (05): : 1043 - 1044
  • [10] MITRAL-VALVE CARPENTIER-EDWARDS BIOPROSTHETIC REPLACEMENT, THROMBOEMBOLISM, AND ANTICOAGULANTS
    LOUAGIE, YA
    JAMART, J
    EUCHER, P
    BUCHE, M
    SCHOEVAERDTS, JC
    EDMUNDS, LH
    [J]. ANNALS OF THORACIC SURGERY, 1993, 56 (04): : 931 - 937