Impact of Angiographic Result After Predilatation on Outcome After Drug-Coated Balloon Treatment of In-Stent Coronary Restenosis

被引:36
|
作者
Tanaka, Akihito [1 ,2 ,3 ]
Latib, Azeem [1 ,2 ,3 ]
Jabbour, Richard J. [1 ,2 ,3 ,4 ]
Kawamoto, Hiroyoshi [1 ,2 ,3 ]
Giannini, Francesco [2 ,3 ]
Ancona, Marco [2 ,3 ]
Regazzoli, Damiano [2 ,3 ]
Mangieri, Antonio [2 ,3 ]
Mattioli, Roberto [5 ]
Chieffo, Alaide [2 ,3 ]
Carlino, Mauro [2 ,3 ]
Montorfano, Matteo [2 ,3 ]
Colombo, Antonio [1 ,2 ,3 ]
机构
[1] EMO GVM Ctr Cuore Columbus, Intervent Cardiol Unit, Milan, Italy
[2] Ist Sci San Raffaele, lntervent Cardiol Unit, Milan, Italy
[3] San Raffaele Univ, Milan, Italy
[4] Imperial Coll London, London, England
[5] Italian Diagnost Ctr, Milan, Italy
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2016年 / 118卷 / 10期
关键词
OPTICAL COHERENCE TOMOGRAPHY; PACLITAXEL-ELUTING BALLOONS; NETWORK METAANALYSIS; ANGIOPLASTY; CLASSIFICATION; IMPLANTATION; STRATEGIES; EFFICACY; TRIALS; SAFETY;
D O I
10.1016/j.amjcard.2016.08.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study investigates clinical outcomes after drug-coated balloon (DCB) treatment for in-stent restenosis (ISR) based on the angiographic result achieved after predilatation and before DCB treatment. Among ISR lesions treated with DCBs, 166 lesions with angiography immediately after predilatation were analyzed. The lesions were divided into 2 groups according to angiographic results after predilatation: (1) "adequate" defined as the presence of Thrombolysis In Myocardial Infarction 3 flow, residual stenosis <= 30%, and no major dissections (n = 98 lesions) or (2) "inadequate" (n = 68 lesions). The reference vessel diameters were larger (2.88 +/- 0.39 vs 2.64 +/- 0.52 mm, p = 0.001) and lesion lengths shorter in the adequate group (15.4 +/- 11.2 vs 19.7 +/- 13.9 mm, p = 0.04). During a median follow, up of 808 days, the cumulative target lesion revascularization (TLR) rate was lower in the adequate group (20.3% vs 35.5% at 2 years; p = 0.04). Multivariate analysis indicated that an angiographically inadequate result before DCB treatment was an independent predictor of TLR, even after adjusting for reference vessel diameter and lesion length (hazard ratio 1.99, 95% confidence interval 1.02 to 3.87, p = 0.04). In conclusion, angiographic results after lesion preparation appear to be a good predictor of TLR after DCB treatment for ISR. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:1460 / 1465
页数:6
相关论文
共 50 条
  • [1] Angiographic and clinical outcomes of patients treated with drug-coated balloon for in-stent restenosis after coronary bifurcation stenting
    Harada, Y.
    Colleran, R.
    Pinieck, S.
    Giacoppo, D.
    Michel, J.
    Kufner, S.
    Cassese, S.
    Wiebe, J.
    Rheude, T.
    Schneider, S.
    Joner, M.
    Ibrahim, T.
    Laugwitz, K. L.
    Kastrati, A.
    Byrne, R. A.
    [J]. EUROPEAN HEART JOURNAL, 2016, 37 : 1060 - 1060
  • [2] Late Stent Thrombosis After Drug-Coated Balloon Coronary Angioplasty for In-Stent Restenosis A Case Report
    Wang, Wenjun
    Wang, Bailu
    Chen, Yuguo
    Wei, Shujian
    [J]. INTERNATIONAL HEART JOURNAL, 2021, 62 (01) : 171 - 174
  • [3] Impact of inadequate angiographic results after pre-dilatation on clinical outcomes following drug-coated balloon treatment for in-stent restenosis
    Tanaka, Akihito
    Latib, Azeem
    Jabbour, Richard
    Kawamoto, Hiroyoshi
    Ancona, Marco
    Regazzoli, Damiano
    Mangieri, Antonio
    Giannini, Francesco
    Azzalini, Lorenzo
    Chieffo, Alaide
    Carlino, Mauro
    Montorfano, Matteo
    Colombo, Antonio
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (18) : B160 - B160
  • [4] Excimer laser coronary angioplasty combined with drug-coated balloon in the treatment of in-stent restenosis
    He, Pan
    Chen, Haiwei
    Yang, Junjie
    Gao, Lei
    Guo, Jun
    Chen, Yundai
    Wang, Qi
    [J]. LASERS IN SURGERY AND MEDICINE, 2024, 56 (05) : 474 - 484
  • [5] Cutting Balloon Combined with Drug-Coated Balloon Angioplasty for the Treatment of In-Stent Restenosis
    Zheng, You-Cheng
    Lee, Wei-Chieh
    Fang, Hsiu-Yu
    Chen, Chien-Jen
    Yang, Cheng-Hsu
    Wu, Chiung-Jen
    Fang, Chih-Yuan
    [J]. INTERNATIONAL HEART JOURNAL, 2021, 62 (06) : 1213 - 1220
  • [6] PREDICTORS OF TARGET LESION REVASCULARIZATION AFTER DRUG-COATED BALLOON ANGIOPLASTY FOR IN-STENT RESTENOSIS
    Mori, Shinsuke
    Ito, Yoshiaki
    Kishida, Toshihiko
    Fukagawa, Tomoya
    Shirai, Shigemitsu
    Makino, Kenji
    Honda, Yohsuke
    Tsutsumi, Masakazu
    Sakamoto, Yasunari
    Kobayashi, Norihiro
    Araki, Motoharu
    Yamawaki, Masahiro
    Hirano, Keisuke
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 1116 - 1116
  • [7] Excimer laser prior to drug-coated balloon treatment of in-stent restenosis
    Alfonso, Fernando
    Rivero, Fernando
    Cortese, Bernardo
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2022, 348 : 47 - 49
  • [8] Angiographic and clinical outcomes of patients treated with drug-coated balloon angioplasty for in-stent restenosis after coronary bifurcation stenting with a two-stent technique
    Harada, Yukinori
    Colleran, Roisin
    Pinieck, Susanne
    Giacoppo, Daniele
    Michel, Jonathan
    Kufner, Sebastian
    Cassese, Salvatore
    Joner, Michael
    Ibrahim, Tareq
    Laugwitz, Karl-Ludwig
    Kastrati, Adnan
    Byrne, Robert A.
    [J]. EUROINTERVENTION, 2017, 12 (17) : 2132 - 2139
  • [9] Drug-coated balloon for recurrent in-stent restenosis treatment: A suitable strategy
    Piraino, Davide
    Buccheri, Dario
    Cimino, Giuliana
    Andolina, Giuseppe
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 221 : 1084 - 1086
  • [10] Impact of chronic kidney disease on long-term outcomes for coronary in-stent restenosis after drug-coated balloon angioplasty
    Lee, Hsin-Fu
    Cheng, Yu-Wen
    Peng, Jian-Rong
    Hsu, Chiu-Yi
    Yang, Chia-Hung
    Chan, Yi-Hsin
    Chu, Pao-Hsien
    [J]. JOURNAL OF CARDIOLOGY, 2021, 78 (06) : 564 - 570