Optimal PMU Placement for Complete Power System Observability under (P-1) Contingency

被引:0
|
作者
Shrivastava, Divya Rishi [1 ]
Siddiqui, Shahbaz Ahmed [1 ]
Verma, Kusum [2 ]
机构
[1] Manipal Univ Jaipur, Dept Elect Engn, Jaipur, Rajasthan, India
[2] Malaviya Natl Inst Technol Jaipur, Dept Elect Engn, Jaipur, Rajasthan, India
关键词
power system observability; phasor measurement unit (PMU); contingency based optimal PMU placement; integer linear programming (ILP);
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
The complete state of the power system can be estimated by optimal number and proper location of Phasor Measurement Units (PMUs). In this paper, an Optimal PMU Placement (OPP) problem that incorporates intact base case conditions and single PMU loss (P-1) contingency resulting in communication failure is formulated. Integer Linear Programming (ILP) is simulated to get optimal number and locations of PMUs in OPP problem. The proposed method is investigated on four test systems: Brazilian 7-bus equivalent system, IEEE 14-bus system, New England 39-bus power system and 145-bus 50 generator power system.
引用
收藏
页码:129 / 132
页数:4
相关论文
共 50 条
  • [21] System Observability Indices for Optimal Placement of PMU Measurements
    Powalko, M.
    Orths, A. G.
    Abildgaard, H.
    Eriksen, P. B.
    Rudion, K.
    Golub, I. I.
    Voropai, N. I.
    2012 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2012,
  • [22] Optimal PMU placement for power system observability considering secondary voltage control
    Mohammadi-Ivatloo, B.
    Hosseini, S. H.
    2008 CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING, VOLS 1-4, 2008, : 352 - +
  • [23] Hierarchical Clustering based optimal PMU placement for power system fault observability
    Eissa, Moustafa
    Kassem, Amr
    HELIYON, 2018, 4 (08):
  • [24] OPTIMAL PLACEMENT OF PMU WITH OPTIMAL BRANCH CURRENT PHASORS FOR COMPLETE AND INCOMPLETE OBSERVABILITY
    Sajan, K. S.
    Tyagi, Barjeev
    2011 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2011,
  • [25] Complete and Incomplete Observability Analysis by Optimal PMU Placement Techniques of a Network
    Krishna, K. Bala
    Rosalina, K. Mercy
    Ramaraj, N.
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2018, 13 (05) : 1814 - 1820
  • [26] Optimal PMU placement for power system observability considering network expansion and N-1 contingencies
    Asgari, Abdolrahim
    Firouzjah, Khalil Gorgani
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2018, 12 (18) : 4216 - 4224
  • [27] Optimal PMU placement for power system observability using BICA, considering measurement redundancy
    Mahari, Arash
    Seyedi, Heresh
    ELECTRIC POWER SYSTEMS RESEARCH, 2013, 103 : 78 - 85
  • [28] Optimal PMU placement for power system observability using Taguchi binary bat algorithm
    Vedik, Basetti
    Chandel, Ashwani K.
    MEASUREMENT, 2017, 95 : 8 - 20
  • [29] Optimal PMU placement for the system observability based on system topology model
    Wang, Hongyu
    Cheng, Xingong
    Zong, Xiju
    PROCEEDINGS 2016 THIRD INTERNATIONAL CONFERENCE ON TRUSTWORTHY SYSTEMS AND THEIR APPLICATIONS (TSA), 2016, : 147 - 151
  • [30] Optimal PMU Placement for Power System Dynamic State Estimation by Using Empirical Observability Gramian
    Qi, Junjian
    Sun, Kai
    Kang, Wei
    2015 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, 2015,