Optimal PMU Placement for Complete Power System Observability under (P-1) Contingency

被引:0
|
作者
Shrivastava, Divya Rishi [1 ]
Siddiqui, Shahbaz Ahmed [1 ]
Verma, Kusum [2 ]
机构
[1] Manipal Univ Jaipur, Dept Elect Engn, Jaipur, Rajasthan, India
[2] Malaviya Natl Inst Technol Jaipur, Dept Elect Engn, Jaipur, Rajasthan, India
关键词
power system observability; phasor measurement unit (PMU); contingency based optimal PMU placement; integer linear programming (ILP);
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
The complete state of the power system can be estimated by optimal number and proper location of Phasor Measurement Units (PMUs). In this paper, an Optimal PMU Placement (OPP) problem that incorporates intact base case conditions and single PMU loss (P-1) contingency resulting in communication failure is formulated. Integer Linear Programming (ILP) is simulated to get optimal number and locations of PMUs in OPP problem. The proposed method is investigated on four test systems: Brazilian 7-bus equivalent system, IEEE 14-bus system, New England 39-bus power system and 145-bus 50 generator power system.
引用
收藏
页码:129 / 132
页数:4
相关论文
共 50 条
  • [1] Optimal PMU placement method for complete topological observability of power system under various contingencies
    Abiri, Ebrahim
    Rashidi, Farzan
    Niknam, Taher
    Salehi, Mohammad Reza
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 61 : 585 - 593
  • [2] Optimal PMU placement method for complete topological and numerical observability of power system
    Sodhi, Ranjana
    Srivastava, S. C.
    Singh, S. N.
    ELECTRIC POWER SYSTEMS RESEARCH, 2010, 80 (09) : 1154 - 1159
  • [3] An optimal PMU placement technique for power system observability
    Roy, B. K. Saha
    Sinha, A. K.
    Pradhan, A. K.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2012, 42 (01) : 71 - 77
  • [4] An Optimal PMU Placement method for Power System Observability
    Raju, V. Vijaya Rama
    Kumar, S. V. Jayarama
    2016 IEEE POWER AND ENERGY CONFERENCE AT ILLINOIS (PECI), 2016,
  • [5] Optimal PMU Placement Considering Contingency-Constraints for Power System Observability and Measurement Redundancy
    Akhlaghi, Shahrokh
    2016 IEEE POWER AND ENERGY CONFERENCE AT ILLINOIS (PECI), 2016,
  • [6] An optimal PMU placement method for power system observability under various contingencies
    Abiri, Ebrahim
    Rashidi, Farzan
    Niknam, Taher
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2015, 25 (04): : 589 - 606
  • [7] Optimal PMU Placement to Achieve Complete Observability of Idaho Power Co. System
    Ciniglio, Orlando
    Papic, Milorad
    Vaiman, Michael
    Vaiman, Marianna
    2017 IEEE POWER & ENERGY SOCIETY INNOVATIVE SMART GRID TECHNOLOGIES CONFERENCE (ISGT), 2017,
  • [8] Optimal PMU Placement in a Power Network for Full System Observability
    Fish, Abdul-Aziz
    Chowdhury, S.
    Chowdhury, S. P.
    2011 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2011,
  • [9] Optimal PMU Placement to Ensure System Observability under Contingencies
    Sodhi, Ranjana
    Srivastava, S. C.
    Singh, S. N.
    2009 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-8, 2009, : 3452 - +
  • [10] Optimal PMU Placement for Complete System Observability and Fault Observability Using Graph Theory
    Ghosh, Pronob K.
    Tahabilder, Anik
    2017 INTERNATIONAL ELECTRICAL ENGINEERING CONGRESS (IEECON), 2017,