Minimum effective volume of 0.5% ropivacaine for ultrasound-guided costoclavicular brachial plexus block A dose finding study

被引:17
|
作者
Wong, Ming H. [1 ]
Karmakar, Manoj K. [1 ]
Mok, Louis Y. H. [1 ]
Songthamwat, Banchobporn [1 ]
Samy, Winnie [1 ]
机构
[1] Chinese Univ Hong Kong, Prince Wales Hosp, Dept Anaesthesia & Intens Care, Shatin, Hong Kong, Peoples R China
关键词
METHODOLOGY; SPACE;
D O I
10.1097/EJA.0000000000001287
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND Costoclavicular brachial plexus block (CC-BPB) is a relatively new regional anaesthetic technique and there are no data on the minimum effective volume 90 (MEV90) of 0.5% ropivacaine required for an ultrasound-guided CC-BPB. OBJECTIVE To determine the MEV90 of 0.5% ropivacaine required to produce surgical anaesthesia with an ultrasound-guided CC-BPB. DESIGN Prospective up-down sequential allocation study design. SETTING University teaching hospital in Hong Kong from March 2016 to December 2017. PATIENTS Forty-eight, ASA physical status I to III patients, aged 70 years or less and scheduled for elective forearm or hand surgery under an ultrasound-guided CC-BPB, were recruited. INTERVENTION Ultrasound-guided CC-BPB was performed with the assigned volume of 0.5% ropivacaine. The Dixon 'up-and-down' sequential allocation method using the biased coin design was used to determine the MEV90 of 0.5% ropivacaine. The assigned volume of ropivacaine was based on the outcome of the previous patient. After a block failure the next patient received a volume increase of 2 ml. If the block was a success, the next patient was allocated, with a probability of b = 0.11, to receive 2 ml less, or, with a probability of 1 - b = 0.89, the same volume. MAIN OUTCOME MEASURES A successful block was defined as a minimum score of 14 of 16 points, using a composite sensory and motor block score at 45 min after the injection. The study was stopped when 45 successful blocks were achieved. MEV90 with 95% confidence interval was calculated using the centred isotonic regression for point and interval dose response studies. RESULTS The MEV90 of 0.5% ropivacaine for ultrasound-guided CC-BPB was 20.9 (95% confidence interval, 20.7 to 21.8) ml. The mean +/- SD time to readiness for surgery was 31.4 +/- 12.60 min. CONCLUSION The MEV90 of 0.5% ropivacaine required to produce surgical anaesthesia with an ultrasound-guided CC-BPB is 20.9 ml.
引用
收藏
页码:780 / 786
页数:7
相关论文
共 50 条
  • [41] Ultrasound-guided infraclavicular brachial plexus block
    Sandhu, NS
    Capan, LM
    BRITISH JOURNAL OF ANAESTHESIA, 2002, 89 (02) : 254 - 259
  • [42] Ultrasound-guided infraclavicular brachial plexus block
    Nadig, M
    Ekatodramis, G
    Borgeat, A
    BRITISH JOURNAL OF ANAESTHESIA, 2003, 90 (01)
  • [43] Ultrasound-guided supraclavicular brachial plexus block
    Chan, VWS
    Perlas, A
    Rawson, R
    Odukoya, O
    ANESTHESIA AND ANALGESIA, 2003, 97 (05): : 1514 - 1517
  • [44] Efficacy of dexmedetomidine used as an adjuvant to 0.5% ropivacaine in ultrasound-guided supraclavicular brachial plexus block for upper limb surgeries
    Jain, Kavita
    Sethi, Surendra Kumar
    Gupta, Vikas
    Garg, Deepak Kumar
    INDIAN ANAESTHETISTS FORUM, 2020, 21 (02): : 121 - 128
  • [45] Comparative Study of the Efficacy of Dexmedetomidine and Fentanyl as Adjuvants to Ropivacaine in Ultrasound-Guided Supraclavicular Brachial Plexus Block
    Dharmarao, Pratibha Shivalgond
    Holyachi, Renuka
    TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2018, 46 (03) : 208 - 213
  • [46] The Minimum Effective Concentration (MEC95) of different volumes of ropivacaine for ultrasound-guided caudal epidural block: a dose-finding study
    Ma, Dongmei
    Chen, Yan
    Chen, Ping
    Xu, Jianhong
    Guo, Jian
    Peng, Lijia
    BMC ANESTHESIOLOGY, 2023, 23 (01)
  • [47] The Minimum Effective Concentration (MEC95) of different volumes of ropivacaine for ultrasound-guided caudal epidural block: a dose-finding study
    Dongmei Ma
    Yan Chen
    Ping Chen
    Jianhong Xu
    Jian Guo
    Lijia Peng
    BMC Anesthesiology, 23
  • [48] Ultrasound-Guided Infraclavicular Brachial Plexus Block Prospective Randomized Comparison of the Lateral Sagittal and Costoclavicular Approach
    Songthamwat, Banchobporn
    Karmakar, Manoj Kumar
    Li, Jia Wei
    Samy, Winnie
    Mok, Louis Y. H.
    REGIONAL ANESTHESIA AND PAIN MEDICINE, 2018, 43 (08) : 825 - 831
  • [49] Minimum effective concentration of bupivacaine for axillary brachial plexus block guided by ultrasound
    Takeda, Alexandre
    Cunha Ferraro, Leonardo Henrique
    Rezende, Andre Hosoi
    Sadatsune, Eduardo Jun
    dos Reis Falcao, Luiz Fernando
    Tardelli, Maria Angela
    REVISTA BRASILEIRA DE ANESTESIOLOGIA, 2015, 65 (03): : 163 - 169
  • [50] Minimum effective volume of ropivacaine for ultrasound-guided supra-inguinal fascia iliaca compartment block
    Yamada, Kumiko
    Inomata, Shinichi
    Saito, Shigeyuki
    SCIENTIFIC REPORTS, 2020, 10 (01)