Maximally Using GPS Observation for Water Vapor Tomography

被引:48
|
作者
Yao, Yibin [1 ,2 ]
Zhao, Qingzhi [3 ]
机构
[1] Wuhan Univ, Sch Geodesy & Geomat, Minist Educ, Key Lab Geospace Environm & Geodesy, Wuhan 430079, Peoples R China
[2] Collaborat Innovat Ctr Geospatial Technol, Wuhan 430079, Peoples R China
[3] Wuhan Univ, Sch Geodesy & Geomat, Wuhan 430079, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
European Centre for Medium-Range Weather Forecasts (ECMWF); radiosonde; tomography boundary; utilization rate; water vapor tomography; NUMERICAL WEATHER PREDICTION; GROUND-BASED GPS; RADIOSONDE; METEOROLOGY; VALIDATION; RESOLUTION; NETWORK; DELAYS;
D O I
10.1109/TGRS.2016.2597241
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
GPS-based water vapor tomography has been proved to be a cost-effective means of obtaining spatial and temporal distribution of atmospheric water vapor. In previous studies, the tomography height is empirically selected without considering the actual characteristics of the local water vapor distribution, and most existing studies only consider the signals passing from the top boundary of the tomography area. Therefore, the observed signals coming out from the side face of the tomography area are excluded as ineffective information, which not only reduces the utilization rate of signals used but also decreases the number of voxels crossed by rays. This becomes the research point of this paper, which studies the possibility of selecting a reasonable tomography boundary and using signals passing from the side face of the tomography area. This paper first tries to determine the tomography height based on the local atmospheric physical property using many years of radiosonde data, and 8 km is selected as the tomography boundary in Hong Kong. The second part focuses on superimposing the signals penetrating from the side face of the tomography area to tomography modeling by introducing a scale factor that is able to determine the water vapor content of each signal with the part that belongs in the tomography area. Finally, a tomography experiment is carried out based on data provided by the Satellite Positioning Reference Station Network (SatRef) in Hong Kong to validate the proposed method. Experimental result demonstrates that the utilization rate of the signal used and the number of voxels crossed by rays are both increased by 30.32% and 12.62%, respectively. The comparison of tomographic integrated water vapor (IWV) derived from different schemes with that from radiosonde and ECMWF data shows that the RMS error of the proposed method (4.1 and 5.1 mm) is smaller than that of the previous method (5.1 and 5.6 mm). In addition, the tomographic water vapor densities derived from different schemes is also compared with those of by radiosonde and ECMWF; the statistical result over the experimental period shows that the proposed method has an average RMS error of 1.23 and 2.12 g/m(3), respectively, which is superior to the previous method at 1.60 and 2.43 g/m(3), respectively.
引用
收藏
页码:7185 / 7196
页数:12
相关论文
共 50 条
  • [31] Analysis on Characteristics of Radiosonde Bias Using GPS Precipitable Water Vapor
    Park, Chang-Geun
    Baek, Jeongho
    Cho, Jungho
    JOURNAL OF ASTRONOMY AND SPACE SCIENCES, 2010, 27 (03) : 213 - 220
  • [32] AN IMPROVED METHOD FOR MERSI WATER VAPOR RETRIEVAL USING GPS CALIBRATION
    Liu, Zhizhao
    Li, Xin
    2016 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS), 2016, : 4139 - 4142
  • [33] Tomographic determination of the spatial distribution of water vapor using GPS observations
    Troller, M.
    Geiger, A.
    Brockmann, E.
    Bettems, J. -M.
    Burki, B.
    Kahle, H. -G.
    ATMOSPHERIC REMOTE SENSING: EARTH'S SURFACE, TROPOSPHERE, STRATOSPHERE AND MESOSPHERE - II, 2006, 37 (12): : 2211 - 2217
  • [34] Assessment of precipitable water vapor over Turkey using GLONASS and GPS
    Gurbuz, Gokhan
    Akgul, Volkan
    Gormus, Kurtulus Sedar
    Kutoglu, Senol Hakan
    JOURNAL OF ATMOSPHERIC AND SOLAR-TERRESTRIAL PHYSICS, 2021, 222
  • [35] 3-D Water Vapor Tomography in Wuhan from GPS, BDS and GLONASS Observations
    Dong, Zhounan
    Jin, Shuanggen
    REMOTE SENSING, 2018, 10 (01)
  • [36] Refining MODIS NIR Atmospheric Water Vapor Retrieval Algorithm Using GPS-Derived Water Vapor Data
    He, Jia
    Liu, Zhizhao
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2021, 59 (05): : 3682 - 3694
  • [37] Applying the Water Vapor Radiometer to Verify the Precipitable Water Vapor Measured by GPS
    Yeh, Ta-Kang
    Hong, Jing-Shan
    Wang, Chuan-Sheng
    Hsiao, Tung-Yuan
    Fong, Chin-Tzu
    TERRESTRIAL ATMOSPHERIC AND OCEANIC SCIENCES, 2014, 25 (02): : 189 - 201
  • [38] Observation system simulation experiments using water vapor isotope information
    Yoshimura, Kei
    Miyoshi, Takemasa
    Kanamitsu, Masao
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2014, 119 (13) : 7842 - 7862
  • [39] Ground-based GPS tomography spatial water vapor distribution with robust variance components estimation
    Zhang, Shuangcheng
    Zhang, Pengfei
    Zhang, Qin
    Ye, Shirong
    Wuhan Daxue Xuebao (Xinxi Kexue Ban)/Geomatics and Information Science of Wuhan University, 2013, 38 (02): : 144 - 147
  • [40] The systematic behavior of water vapor estimates using four years of GPS observations
    Emardson, TR
    Johansson, J
    Elgered, G
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2000, 38 (01): : 324 - 329