Aging Characteristics of Inter-turn Insulation of Form-wound Stator Windings of Inverter-fed AC Motors

被引:7
|
作者
Zhou, Kai [1 ]
Wan, Li [1 ]
Li, Xutao [1 ]
机构
[1] Sichuan Univ, Sch Elect Engn & Informat, Chengdu 610065, Peoples R China
关键词
square-wave pulse; partial discharges; inter-turn insulation; aging; memory effect; phase-resolved partial discharge patterns; VOLTAGE; WIRE;
D O I
10.1080/15325008.2013.816979
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Phase-resolved partial discharge patterns of an inter-turn insulation specimen for a stator winding are investigated at different aging times under continuous square-wave pulse voltage. Comparing phase-resolved partial discharge patterns after square-wave pulse-voltage aging to those after sinusoidal-voltage aging, obvious independent clusters of discharge numbers occur with increases in the aging time of pulse voltage, whereas no similar phenomenon is observed after sinusoidal-voltage aging. Based on detailed analysis, partial discharge activity in a larger void is more intense, because the larger void has a larger memory effect, which is related to the number of residual charges. The enhanced electric field of the larger void accelerates the increase in void size. Furthermore, when the phase-resolved partial discharge patterns are measured under 50 Hz of sinusoidal voltage, since sinusoidal voltage creates less memory effect due to less residual charges, the corresponding partial discharges of different-sized voids occur at distinctly different phases of the sinusoidal voltage. For this reason, the independent clusters occur and become obvious with pulse-voltage aging. As a result, for pulse-width-modulated motors in industry, it is possible to evaluate the insulation condition through phase-resolved partial discharge patterns using 50 Hz partial discharge measurement.
引用
收藏
页码:1280 / 1293
页数:14
相关论文
共 50 条
  • [41] PD Characteristics and Microscopic Analysis of Polyimide Film Used as Turn Insulation in Inverter-fed Motor
    Luo, Yang
    Wu, Guangning
    Liu, Jiwu
    Zhu, Guangya
    Wang, Peng
    Peng, Jia
    Cao, Kaijang
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (05) : 2237 - 2244
  • [42] Partial Discharge Characteristics of Twisted Enameled Magnet Wires for Inverter-fed Random Wound Motors
    Kikuchi, Yusuke
    Miyamae, Masanori
    Fukuda, Yuki
    Nagata, Masayoshi
    Tuda, Toshihiro
    Tsutsui, Hirotsugu
    Ikegami, Tomomi
    Sakurai, Takayuki
    Yamada, Shinichiro
    Yoshimitsu, Tetsuo
    [J]. PROCEEDINGS OF 2011 INTERNATIONAL CONFERENCE ON ELECTRICAL INSULATING MATERIALS (ISEIM), 2011, : 125 - 127
  • [43] Characteristics of inter-turn voltage oscillation in typical graded insulation windings of ultra-high voltage transformers
    Zheng, Yiming
    Wang, Zanji
    [J]. Gaodianya Jishu/High Voltage Engineering, 2014, 40 (12): : 3933 - 3941
  • [44] An Online Groundwall Insulation Monitoring Method Based on Transient Characteristics of Leakage Current for Inverter-Fed Motors
    Niu, Feng
    Wang, Yunlong
    Huang, Shaopo
    Wu, Lijian
    Huang, Xiaoyan
    Fang, Youtong
    Yang, Tao
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (08) : 9745 - 9753
  • [45] Stator circulating current characteristics in nuclear turbine generator after rotor windings inter-turn short circuit fault
    Wu Y.-C.
    Ma G.-H.
    [J]. Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2020, 24 (03): : 45 - 52and61
  • [46] Impact of inverter drives employing fast-switching devices on form-wound AC machine stator cod stress grading
    Espino-Cortes, F. P.
    Cherney, E. A.
    Jayaram, S. H.
    [J]. IEEE ELECTRICAL INSULATION MAGAZINE, 2007, 23 (01) : 16 - 28
  • [47] Inter-turn short-circuit fault detection with high-frequency signal injection for inverter-fed PMSM systems
    Zheng Xu
    Jianzhong Zhang
    Zakiud Din
    Yongbin Wu
    Ming Cheng
    [J]. Journal of Power Electronics, 2023, 23 : 892 - 903
  • [48] Electrical aging of inverter-fed wire-wound induction motors: from quality control to end of life
    Cavallini, A.
    Montanari, G. C.
    Tozzi, M.
    [J]. CONFERENCE RECORD OF THE 2010 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION (ISEI), 2010,
  • [49] Inter-turn short-circuit fault detection with high-frequency signal injection for inverter-fed PMSM systems
    Xu, Zheng
    Zhang, Jianzhong
    Din, Zakiud
    Wu, Yongbin
    Cheng, Ming
    [J]. JOURNAL OF POWER ELECTRONICS, 2023, 23 (06) : 892 - 903
  • [50] Comparative Study Of Inter-Turn Short Circuit Fault In Stator And Rotor Windings On A Small and Medium Power Wound Rotor Induction Machine
    Razafimahefa, T. D.
    Heraud, N.
    Sambatra, E. J. R.
    Wailly, O.
    [J]. 2015 23RD MEDITERRANEAN CONFERENCE ON CONTROL AND AUTOMATION (MED), 2015, : 184 - 189