Cuffless Blood Pressure Estimation During Moderate- and Heavy-Intensity Exercise Using Wearable ECG and PPG

被引:5
|
作者
Landry, Cederick [1 ]
Hedge, Eric T. [2 ,3 ]
Hughson, Richard L. [2 ]
Peterson, Sean D. [1 ]
Arami, Arash [1 ,4 ]
机构
[1] Univ Waterloo, Mech & Mechatron Engn Dept, Waterloo, ON N2L 3G1, Canada
[2] Univ Waterloo, Dept Kinesiol & Hlth Sci, Waterloo, ON N2J 3G1, Canada
[3] Schlegel Univ Waterloo Res Inst Aging, Waterloo, ON N2J 0E2, Canada
[4] Univ Hlth Network, Toronto Rehabil Inst, Toronto, ON M5G 2C4, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Artificial neural network; blood pressure changes; cuffless blood pressure; electrocardiography; exercise physiology; heavy-intensity exercise; peripheral resistance; photoplethysmography; PULSE TRANSIT-TIME; WAVE-FORM; OXYGEN-UPTAKE; FOREHEAD; KINETICS;
D O I
10.1109/JBHI.2022.3207947
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Objective: To develop and evaluate an accurate method for cuffless blood pressure (BP) estimation during moderate- and heavy-intensity exercise. Methods: Twelve participants performed three cycling exercises: a ramp-incremental exercise to exhaustion, and moderate and heavy pseudorandom binary sequence exercises on an electronically braked cycle ergometer over the course of 21 minutes. Subject-specific and population-based nonlinear autoregressive models with exogenous inputs (NARX) were compared with feedforward artificial neural network (ANN) models and pulse arrival time (PAT) models. Results: Population-based NARX models, (applying leave-one-subject-out cross-validation), performed better than the other models and showed good capability for estimating large changes in mean arterial pressure (MAP). The models were unable to track consistent decreases in BP during prolonged exercise caused by reduction in peripheral vascular resistance, since this information is apparently not encoded in the employed proxy physiological signals (electrocardiography and forehead PPG) used for BP estimation. Nevertheless, the population-based NARX model had an error standard deviation of 11.0 mmHg during the entire exercise window, which improved to 9.0 mmHg when the model was periodically calibrated every 7 minutes. Conclusion: Population-based NARX models can estimate BP during moderate- and heavy-intensity exercise but need periodic calibration to account for the change in vascular resistance during exertion. Significance: MAP can be continuously tracked during exercise using only wearable sensors, making monitoring exercise physiology more convenient and accessible.
引用
收藏
页码:5942 / 5952
页数:11
相关论文
共 50 条
  • [21] Accurate Blood Pressure Estimation During Activities of Daily Living: A Wearable Cuffless Solution
    Landry, Cederick
    Hedge, Eric T.
    Hughson, Richard L.
    Peterson, Sean D.
    Arami, Arash
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2021, 25 (07) : 2510 - 2520
  • [22] Acute respiratory muscle unloading improves time-to-exhaustion during moderate- and heavy-intensity cycling in obese adolescent males
    Alemayehu, Hailu Kinfu
    Salvadego, Desy
    Tringali, Gabriella
    De Micheli, Roberta
    Caccavale, Mara
    Sartorio, Alessandro
    Grassi, Bruno
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [23] Acute respiratory muscle unloading improves time-to-exhaustion during moderate- and heavy-intensity cycling in obese adolescent males
    Hailu Kinfu Alemayehu
    Desy Salvadego
    Gabriella Tringali
    Roberta De Micheli
    Mara Caccavale
    Alessandro Sartorio
    Bruno Grassi
    Scientific Reports, 10
  • [24] Systolic blood pressure estimation using ECG and PPG in patients undergoing surgery
    Sun, Shaoxiong
    Bresch, Erik
    Muehlsteff, Jens
    Schmitt, Lars
    Long, Xi
    Bezemer, Rick
    Paulussen, Igor
    Noordergraaf, Gerrit J.
    Aarts, Ronald M.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 79
  • [25] Blood Pressure Estimation Based on PPG and ECG Signals Using Knowledge Distillation
    Tang, Hui
    Ma, Gang
    Qiu, Lishen
    Zheng, Lesong
    Bao, Rui
    Liu, Jing
    Wang, Lirong
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2024, 15 (01) : 39 - 51
  • [26] Estimation of Blood Pressure by Using Electrocardiogram(ECG) and Photo-plethysmogram(PPG)
    Kumar, Sarvesh
    Ayub, Shahanaz
    2015 FIFTH INTERNATIONAL CONFERENCE ON COMMUNICATION SYSTEMS AND NETWORK TECHNOLOGIES (CSNT2015), 2015, : 521 - 524
  • [27] Blood Pressure Estimation Based on PPG and ECG Signals Using Knowledge Distillation
    Hui Tang
    Gang Ma
    Lishen Qiu
    Lesong Zheng
    Rui Bao
    Jing Liu
    Lirong Wang
    Cardiovascular Engineering and Technology, 2024, 15 : 39 - 51
  • [28] Cuffless blood pressure estimation from PPG signals and its derivatives using deep learning models
    El-Hajj, C.
    Kyriacou, P. A.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2021, 70
  • [29] Using a New PPG Indicator to increase the Accuracy of PTT-based Continuous Cuffless Blood Pressure Estimation
    Lin, Wan-Hua
    Wang, Hui
    Samuel, Oluwarotimi Williams
    Li, Guanglin
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 738 - 741
  • [30] Cuffless Blood Pressure Estimation Using Pulse Transit Time and Photoplethysmogram Intensity Ratio
    Gholamhosseini, Hamid
    Baig, Mirza
    Rastegar, Solmaz
    Linden, Maria
    PROCEEDINGS OF THE 15TH INTERNATIONAL CONFERENCE ON WEARABLE MICRO AND NANO TECHNOLOGIES FOR PERSONALIZED HEALTH (PHEALTH 2018), 2018, 249 : 77 - 83