Experimental and numerical investigations of a high-head pumped-storage power plant at speed no-load

被引:5
|
作者
Decaix, J. [1 ]
Hasmatuchi, V. [1 ]
Titzschkau, M. [2 ]
Rapillard, L. [1 ]
Manso, P. [3 ]
Avellan, F. [4 ]
Munch-Alligne, C. [1 ]
机构
[1] Univ Appl Sci & Arts Western Switzerland Valais, Route Rawil 47, CH-1950 Sion, Switzerland
[2] Kraftwerke Oberhasli AG KWO, Grimsel Hydro, Innertkirchen, Switzerland
[3] Ecole Polytech Fed Lausanne, Plateforme Construct Hydraul PL LCH, CH-1015 Lausanne, Switzerland
[4] Ecole Polytech Fed Lausanne, Lab Machines Hydraul, CH-1007 Lausanne, Switzerland
关键词
D O I
10.1088/1755-1315/240/8/082014
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Due to the increasing integration of new renewable energies, the electrical grid undergoes more frequent instabilities. Hydroelectric power plants, particularly pumped storage plants, are well suited for grid control. However, this objective requires extending the operating range of the machines and increasing the number of start-up, stand-by and shut-down procedures, which reduces the lifespan of the machines due to high mechanical stresses. The current study focuses on a pumped-storage power plant equipped with ternary groups. Recently, cracks on the runner blades of the Francis turbine have been observed without finding a clear explanation for their onset. During this period, the number of starts and stops per day has strongly increased. In order to better understand the origin of the fatigue of the turbine runner, external and on-board measurements along with CFD and FEM investigations have been performed. The on-board measurements provide evidence high mechanical stresses on the runner blades during the synchronization of the machine at speed no-load (SNL) operating condition. The frequency spectrum observed on the various signals suggests that the high stresses are linked to the excitation of one of the runner modes by some flow instabilities, which is supported by the CFD and FEM analyses.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] THE MARKERSBACH PUMPED-STORAGE STATION - AN ADVANCED PEAK LOAD PLANT ADDED TO THE GDRS POWER INDUSTRY
    HEMPEL, M
    ENERGIETECHNIK, 1981, 31 (07): : 243 - 246
  • [22] Analysis of systems for excitation of variable-speed pumped-storage power-plant hydrogenerators
    I. Ya. Dovganyuk
    R. D. Mnev
    T. V. Plotnikova
    P. V. Sokur
    P. Yu. Tuzov
    Russian Electrical Engineering, 2012, 83 (6) : 337 - 341
  • [23] A High Head Pumped Storage Power Plant Rehabilitation Project
    Nakamura, Kazuyuki
    Shigenobu, Takashi
    Harada, Sho
    Muraki, Takaaki
    INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY RESEARCH AND APPLICATIONS (ICRERA), 2012,
  • [24] Intelligent identification of underground powerhouse of pumped-storage power plant
    Sun, WQ
    Ma, ZY
    Yan, XD
    Qi, JX
    Do, XJ
    ACTA MECHANICA SINICA, 2005, 21 (02) : 187 - 191
  • [25] Optimization and Mechanism of the Wicket Gate Closing Law for High-Head Pumped Storage Power Stations
    Liu, Chang
    Zhou, Jianzhong
    Lai, Xinjie
    Zhang, Tianyu
    IEEE ACCESS, 2021, 9 : 11734 - 11749
  • [26] 50 YEARS OF THE NIEDERWARTHA PUMPED-STORAGE POWER-PLANT
    DIESSNER, W
    ENERGIETECHNIK, 1980, 30 (01): : 36 - 38
  • [27] Intelligent identification of underground powerhouse of pumped-storage power plant
    Wanquan Sun
    Zhenyue Ma
    Xudong Yan
    Junxiu Qi
    Xiaojing Du
    Acta Mechanica Sinica, 2005, 21 : 187 - 191
  • [28] Optimal Scheduling of a Pumped-Storage Hydro Power Plant Operation
    Hering, Pavel
    Mosna, Jiri
    Janecek, Eduard
    Hrycej, David
    2013 13TH INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING (EEEIC), 2013, : 166 - 171
  • [29] HIGH-HEAD PUMPED STORAGE COOLS ITS NUCLEAR PARTNER.
    Anon
    Engineering News-Record, 1977, 198 (17): : 20 - 21
  • [30] Combined storage routing for the upper and the lower reservoirs of pumped-storage power plant
    Wang, Hongbiao
    Shuili Fadian/Water Power, (03): : 3 - 7