EFFECTS OF DIFFERENT LATERAL FEMORAL WALL THICKNESSES IN INTERTROCHANTERIC HIP FRACTURE TREATED WITH DYNAMIC HIP SCREW

被引:2
|
作者
Wang, Cheng-Chi [1 ,2 ]
Lee, Cheng-Hung [1 ,3 ]
Chen, Kun-Hui [1 ,4 ]
Pan, Chien-Chou [1 ]
Su, Kuo-Chih [4 ,5 ]
机构
[1] Taichung Vet Gen Hosp, Dept Orthoped, Taichung, Taiwan
[2] Nantou Hosp, Minist Hlth & Welf, Dept Orthoped, Nantou, Taiwan
[3] Hung Kuang Univ, Dept Food Sci & Technol, Taichung, Taiwan
[4] Hung Kuang Univ, Dept Biomed Engn, Taichung, Taiwan
[5] Taichung Vet Gen Hosp, Dept Med Res, Taichung, Taiwan
关键词
Biomechanics; finite element analysis; dynamic hip screw; intertrochanteric hip fracture; lateral femoral wall thickness; FINITE-ELEMENT; PREDICTOR;
D O I
10.1142/S0219519419400220
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Dynamic hip screw (DHS) is commonly used for stable-type intertrochanteric hip fractures. The importance of lateral femoral wall has been mentioned while treating intertrochanteric hip fractures with DHS. The aim of this study was mainly to investigate the biomechanical effect of different thickness of lateral femoral wall using finite element analysis (FEA). This study constructed FEA simulation models for five different lateral femoral wall thicknesses, and demonstrated the stress distribution on the femoral bone, the cortical screws, the cancellous bone around the lag screw, and the lag screw. The main results showed that when the DHS is implanted, less stress will be distributed at the implantation site on the femur due to the stress-shielding effect. The stress on the cortical screws will be greater at the junction of the cortical screws and the cortical bone. Intertrochanteric hip fractures with a thinner lateral wall thickness may cause higher stress on the femur after DHS is implanted.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Biomechanical investigation of dynamic hip screw and wire fixation on an unstable intertrochanteric fracture
    Wu, Hsu-Fu
    Chang, Chih-Han
    Wang, Gwo-Jaw
    Lai, Kuo-An
    Chen, Chung-Hwan
    BIOMEDICAL ENGINEERING ONLINE, 2019, 18 (1)
  • [32] Biomechanical investigation of dynamic hip screw and wire fixation on an unstable intertrochanteric fracture
    Hsu-Fu Wu
    Chih-Han Chang
    Gwo-Jaw Wang
    Kuo-An Lai
    Chung-Hwan Chen
    BioMedical Engineering OnLine, 18
  • [33] Biomechanical analysis of location of lag screw of a dynamic hip screw in treatment of unstable intertrochanteric fracture
    Wu, CC
    Shih, CH
    Lee, MY
    Tai, CL
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1996, 41 (04): : 699 - 702
  • [34] Comparison of Dynamic Hip Screw and Proximal Femoral Nailing Techniques in Stable Intertrochanteric Fractures
    Shiraz, Salman
    Shujauddin, Mohammad
    Hasan, Khalid
    Elramadi, Ahmed
    Ahmed, Ghalib
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (01)
  • [35] COMPARATIVE STUDY OF PROXIMAL FEMORAL NAILING AND DYNAMIC HIP SCREW FOR INTERTROCHANTERIC FRACTURES IN ADULTS
    Koduru, Satya Kumar
    Potluri, Siddharth
    Rao, C. Hanumantha
    Raghav, Srinivas T.
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2016, 5 (35): : 2018 - 2021
  • [36] Comparative study of InterTAN and Dynamic Hip Screw in treatment of femoral intertrochanteric injury and wound
    Wang, Qiang
    Yang, Xin
    He, Hua-Zheng
    Dong, Li-Jun
    Huang, De-Gang
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2014, 7 (12): : 5578 - 5582
  • [37] A Case Report of Paediatric Post Traumatic Closed Intertrochanteric Fracture of Left Femur Treated with Dynamic Hip Screw
    Krishnan, Navaneetha R.
    Reddy, Vijaynarasimman
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2021, 9 (11): : 73 - 74
  • [38] Integrity of the lateral femoral wall in intertrochanteric hip fractures: An important predictor of a reoperation - Reply
    Palm, Henrik
    Jacobsen, Stcffcn
    Sonnc-Holm, Stig
    Gebuhr, Peter
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (11): : 2553 - 2553
  • [39] Perioperative Lateral Trochanteric Wall Fractures: Sliding Hip Screw versus Percutaneous Compression Plate for Intertrochanteric Hip Fractures
    Langford, Joshua
    Pillai, Gita
    Ugliailoro, Anthony D.
    Yang, Edward
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (04) : 191 - 195
  • [40] Proximal femoral locking plate versus dynamic hip screw for unstable intertrochanteric femoral fractures Reply
    Dhamangaonkar, Anoop C.
    JOURNAL OF ORTHOPAEDIC SURGERY, 2014, 22 (01): : 131 - 132