Nonenzymatic Glucose Detection in Human Serum Using Ni Nanoparticles Decorated Reduced Graphene Oxide

被引:2
|
作者
Waichal, Rupali [1 ,2 ]
Bhirud, Ashwini [3 ]
Fouad, H. [4 ,5 ]
Gosavi, Suresh [3 ]
Ashokkumar, Muthupandian [6 ]
机构
[1] Savitribai Phule Pune Univ, Sch Basic Med Sci, Pune 411007, Maharashtra, India
[2] Natl Chem Lab NCL, Phys & Mat Chem Div, Dr HomiBhabha Rd, Pune 411008, Maharashtra, India
[3] Savitribai Phule Pune Univ, Dept Phys, Pune 411007, Maharashtra, India
[4] King Saud Univ, Community Coll, Appl Med Sci Dept, Riyadh 11433, Saudi Arabia
[5] Helwan Univ, Fac Engn, Biomed Engn Dept, Helwan 11792, Egypt
[6] Univ Melbourne, Sch Chem, Melbourne, Vic 3010, Australia
关键词
Hydrothermal; Nanocomposite; Glucose Sensor; Electrochemical; Nonenzymatic; Graphene-Nickel Nanoparticles; IN-SITU PREPARATION; ELECTROCHEMICAL DETECTION; NICKEL NANOPARTICLES; 3-DIMENSIONAL GRAPHENE; AMPEROMETRIC BIOSENSOR; HYDROGEN-PEROXIDE; POROUS GRAPHENE; SENSOR; NANOCOMPOSITE; ELECTRODES;
D O I
10.1166/sam.2020.3776
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Reduced Graphene oxide (RGO) decorated with Ni nanoparticles (NiNPs) composites, have been successfully synthesized using a simple hydrothermal method and possessing excellent electrocatalytic activity towards glucose oxidation. The morphological and structural features of RGO-Ni nanocomposites were characterized by field emission scanning electron microscopy (FESEM), transmission electron microscopy (TEM), X-ray diffraction (XRD), Raman spectroscopy, X-ray photoelectron spectroscopy (XPS) and energy dispersive spectroscopy (EDS). From TEM, we observed that NiNPs were anchored on RGO sheets. Cyclic Voltammetric (CV) study revealed that the electrocatalytic activity of RGO-Ni nanocomposite with 20% Ni loading (RGONi-20) towards glucose oxidation is better than that shown by bare Glassy Carbon Electrode (GCE), RGO, bare NiNPs, RGONi10 and RGONi-30. The prepared nanocomposites exhibited fast electrocatalytic response (<5 s) towards glucose oxidation. Amperometric study indicates that the present glucose sensor have exhibited excellent performance by offering a lowest detection limit as 5.1 mu M, with linier range from 2 to 5000 mu M and high sensitivity of 896.67 mu A mM(-1) cm(-2). Interference from different anticipatable electroactive substances such as ascorbic acid (AA), uric acid (UA) and dopamine (DA) is not observed. Furthermore, the application of the as prepared sensor was successfully demonstrated for the detection of glucose in human serum and results were comparable to presently used nonenzymatic technique. RGONi-20 nanocomposite electrode holds great promise for the development of biosensors and other electrochemical devices.
引用
收藏
页码:1125 / 1136
页数:12
相关论文
共 50 条
  • [21] Ni nanoparticles decorated titania nanotube arrays as efficient nonenzymatic glucose sensor
    Yu, Shujuan
    Peng, Xiao
    Cao, Guozhong
    Zhou, Ming
    Qiao, Lei
    Yao, Jianyu
    He, Huichao
    ELECTROCHIMICA ACTA, 2012, 76 : 512 - 517
  • [22] Hg(II) Ion Detection Using Thermally Reduced Graphene Oxide Decorated with Functionalized Gold Nanoparticles
    Chen, Kehung
    Lu, Ganhua
    Chang, Jingbo
    Mao, Shun
    Yu, Kehan
    Cui, Shumao
    Chen, Junhong
    ANALYTICAL CHEMISTRY, 2012, 84 (09) : 4057 - 4062
  • [23] In-situ synthesis of Pt nanoparticles/reduced graphene oxide/cellulose nanohybrid for nonenzymatic glucose sensing
    Dong, Lili
    Ren, Suxia
    Zhang, Xiuqiang
    Yang, Yantao
    Wu, Qinglin
    Lei, Tingzhou
    CARBOHYDRATE POLYMERS, 2023, 303
  • [24] Plain to point network reduced graphene oxide - activated carbon composites decorated with platinum nanoparticles for urine glucose detection
    Hossain, Mohammad Faruk
    Park, Jae Y.
    SCIENTIFIC REPORTS, 2016, 6
  • [25] Plain to point network reduced graphene oxide - activated carbon composites decorated with platinum nanoparticles for urine glucose detection
    Mohammad Faruk Hossain
    Jae Y. Park
    Scientific Reports, 6
  • [26] A NiFe Alloy Reduced on Graphene Oxide for Electrochemical Nonenzymatic Glucose Sensing
    Deng, Zhe-Peng
    Sun, Yu
    Wang, Yong-Cheng
    Gao, Jian-De
    SENSORS, 2018, 18 (11)
  • [27] Optimized electrochemical synthesis of copper nanoparticles decorated reduced graphene oxide: Application for enzymeless determination of glucose in human blood
    Balasubramanian, Paramasivam
    Velmurugan, Murugan
    Chen, Shen-Ming
    Hwa, Kuo-Yuan
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 807 : 128 - 136
  • [28] Functionalized Gold Nanoparticles Decorated Reduced Graphene Oxide Sheets for Efficient Detection of Mercury
    Sett, Avik
    Bhattacharyya, Tarun Kanti
    IEEE SENSORS JOURNAL, 2020, 20 (11) : 5712 - 5719
  • [29] Green synthesis of reduced graphene oxide decorated with gold nanoparticles and its glucose sensing application
    Tabrizi, Mahmoud Amouzadeh
    Varkani, Javad Nadali
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 202 : 475 - 482
  • [30] Sonochemical synthesis of bismuth(III) oxide decorated reduced graphene oxide nanocomposite for detection of hormone (epinephrine) in human and rat serum
    Manavalan, Shaktivel
    Rajaji, Umamaheswari
    Chen, Shen-Ming
    Govindasamy, Mani
    Selvin, S. Steplin Paul
    Chen, Tse-Wei
    Ali, M. Ajmal
    Al-Hemaid, Fahad M. A.
    Elshikh, M. S.
    ULTRASONICS SONOCHEMISTRY, 2019, 51 : 103 - 110