Nonenzymatic Glucose Detection in Human Serum Using Ni Nanoparticles Decorated Reduced Graphene Oxide

被引:2
|
作者
Waichal, Rupali [1 ,2 ]
Bhirud, Ashwini [3 ]
Fouad, H. [4 ,5 ]
Gosavi, Suresh [3 ]
Ashokkumar, Muthupandian [6 ]
机构
[1] Savitribai Phule Pune Univ, Sch Basic Med Sci, Pune 411007, Maharashtra, India
[2] Natl Chem Lab NCL, Phys & Mat Chem Div, Dr HomiBhabha Rd, Pune 411008, Maharashtra, India
[3] Savitribai Phule Pune Univ, Dept Phys, Pune 411007, Maharashtra, India
[4] King Saud Univ, Community Coll, Appl Med Sci Dept, Riyadh 11433, Saudi Arabia
[5] Helwan Univ, Fac Engn, Biomed Engn Dept, Helwan 11792, Egypt
[6] Univ Melbourne, Sch Chem, Melbourne, Vic 3010, Australia
关键词
Hydrothermal; Nanocomposite; Glucose Sensor; Electrochemical; Nonenzymatic; Graphene-Nickel Nanoparticles; IN-SITU PREPARATION; ELECTROCHEMICAL DETECTION; NICKEL NANOPARTICLES; 3-DIMENSIONAL GRAPHENE; AMPEROMETRIC BIOSENSOR; HYDROGEN-PEROXIDE; POROUS GRAPHENE; SENSOR; NANOCOMPOSITE; ELECTRODES;
D O I
10.1166/sam.2020.3776
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Reduced Graphene oxide (RGO) decorated with Ni nanoparticles (NiNPs) composites, have been successfully synthesized using a simple hydrothermal method and possessing excellent electrocatalytic activity towards glucose oxidation. The morphological and structural features of RGO-Ni nanocomposites were characterized by field emission scanning electron microscopy (FESEM), transmission electron microscopy (TEM), X-ray diffraction (XRD), Raman spectroscopy, X-ray photoelectron spectroscopy (XPS) and energy dispersive spectroscopy (EDS). From TEM, we observed that NiNPs were anchored on RGO sheets. Cyclic Voltammetric (CV) study revealed that the electrocatalytic activity of RGO-Ni nanocomposite with 20% Ni loading (RGONi-20) towards glucose oxidation is better than that shown by bare Glassy Carbon Electrode (GCE), RGO, bare NiNPs, RGONi10 and RGONi-30. The prepared nanocomposites exhibited fast electrocatalytic response (<5 s) towards glucose oxidation. Amperometric study indicates that the present glucose sensor have exhibited excellent performance by offering a lowest detection limit as 5.1 mu M, with linier range from 2 to 5000 mu M and high sensitivity of 896.67 mu A mM(-1) cm(-2). Interference from different anticipatable electroactive substances such as ascorbic acid (AA), uric acid (UA) and dopamine (DA) is not observed. Furthermore, the application of the as prepared sensor was successfully demonstrated for the detection of glucose in human serum and results were comparable to presently used nonenzymatic technique. RGONi-20 nanocomposite electrode holds great promise for the development of biosensors and other electrochemical devices.
引用
收藏
页码:1125 / 1136
页数:12
相关论文
共 50 条
  • [1] Reduced graphene oxide nanosheets decorated with cobalt oxide nanoparticles: A nonenzymatic electrochemical approach for glucose detection
    Maghsoudi, Shahab
    Mohammadi, Arman
    SYNTHETIC METALS, 2020, 269
  • [2] Design and fabrication of Ag-CuO nanoparticles on reduced graphene oxide for nonenzymatic detection of glucose
    Xu, Da
    Zhu, Chengling
    Meng, Xin
    Chen, Zhixin
    Li, Yao
    Zhang, Di
    Zhu, Shenmin
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 265 : 435 - 442
  • [3] Electrochemical detection of chloramphenicol using palladium nanoparticles decorated reduced graphene oxide
    Yi, Wenwen
    Li, Zhongping
    Dong, Chuan
    Li, Hung-Wing
    Li, Junfen
    MICROCHEMICAL JOURNAL, 2019, 148 : 774 - 783
  • [4] Green synthesis of copper oxide nanoparticles decorated reduced graphene oxide for high sensitive detection of glucose
    Pourbeyram, Sima
    Abdollahpour, Jamal
    Soltanpour, Maryam
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2019, 94 : 850 - 857
  • [5] Cu@Ni core-shell nanoparticles/reduced graphene oxide nanocomposites for nonenzymatic glucose sensor
    Wu, Kong-Lin
    Cai, Ya-Miao
    Jiang, Bin-Bin
    Cheong, Weng-Chon
    Wei, Xian-Wen
    Wang, Weizhi
    Yu, Nan
    RSC ADVANCES, 2017, 7 (34): : 21128 - 21135
  • [6] Cu@Ni core-shell nanoparticles/reduced graphene oxide nanocomposites for nonenzymatic glucose sensor
    Wu K.-L.
    Cai Y.-M.
    Jiang B.-B.
    Cheong W.-C.
    Wei X.-W.
    Wang W.
    Yu N.
    Wu, K.-L. (konglin@mail.ahnu.edu.cn), 1600, Royal Society of Chemistry (07): : 21128 - 21135
  • [7] Au nanoparticles decorated reduced graphene oxide for the fabrication of disposable nonenzymatic hydrogen peroxide sensor
    Dhara, Keerthy
    Ramachandran, T.
    Nair, Bipin G.
    Babu, T. G. Satheesh
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 764 : 64 - 70
  • [8] Electrochemical Deposition of Nickel Nanoparticles on Reduced Graphene Oxide Film for Nonenzymatic Glucose Sensing
    Zhang, Yue
    Xiao, Xianping
    Sun, Yujing
    Shi, Yan
    Dai, Haichao
    Ni, Pengjuan
    Hu, Jingting
    Li, Zhuang
    Song, Yonghai
    Wang, Li
    ELECTROANALYSIS, 2013, 25 (04) : 959 - 966
  • [9] Electrochemical fabrication of Ni nanoparticles-decorated electrochemically reduced graphene oxide composite electrode for non-enzymatic glucose detection
    Urhan, Bingul Kurt
    Demir, Umit
    Ozer, Tuba Oznuluer
    Dogan, Hulya Ozturk
    THIN SOLID FILMS, 2020, 693
  • [10] 3D porous structured polyaniline/reduced graphene oxide/copper oxide decorated electrode for high performance nonenzymatic glucose detection
    Fang, Lu
    Zhu, Qin
    Cai, Yu
    Liang, Bo
    Ye, Xuesong
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 841 : 1 - 9