Comparison of native myocardial T1 and T2 mapping at 1.5T and 3T in healthy volunteers Reference values and clinical implications

被引:57
|
作者
Granitz, Marcel [1 ]
Motloch, Lukas J. [2 ]
Granitz, Christina [2 ]
Meissnitzer, Matthias [1 ]
Hitzl, Wolfgang [3 ]
Hergan, Klaus [1 ]
Schlattau, Alexander [1 ]
机构
[1] Paracelsus Med Univ, Dept Radiol, Mullner Hauptstr 48, A-5020 Salzburg, Austria
[2] Paracelsus Med Univ, Dept Internal Med 2, Salzburg, Austria
[3] Paracelsus Med Univ, Res Off Biostat, Salzburg, Austria
关键词
Cardiac; MRI; Normal; Field strength; CARDIOVASCULAR MAGNETIC-RESONANCE; T-1; AGE; VALIDATION; FIBROSIS; DISEASE;
D O I
10.1007/s00508-018-1411-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Myocardial native T1 and T2 mapping are promising techniques for quantitative assessment of diffuse myocardial pathologies; however, due to conflicting data regarding normal values, routine clinical implementation of this method is still challenging. Methods To evaluate this situation during daily clinical practice the characteristics of normal values obtained in 60 healthy volunteers who underwent magnetic resonance imaging (MRI) scans on 1.5T and 3T scanners were studied. The T1 modified look-locker inversion recovery (MOLLI; 5(3)3; modified for higher heart rates) and T2 navigator gated black-blood prepared gradient-spin-echo (GraSE) sequences were used. Results While age and body mass index did not affect relaxation times, a gender and heart rate dependency was found showing higher T1 and T2 values in females, whereas at higher heart rates a prolongation of T1 and a shortening of T2 relaxation times was found. Particularly prone to artifacts were T2 measurements at 3T and the inferolateral wall. In the individual setting mean relaxation times for T1 were 995.8 +/- 30.9 ms at 1.5T and 1183.8 +/- 37.5 ms at 3T and 55.8 +/- 2.8 ms at 1.5T and 51.6 +/- 3 ms at 3T for T2 indicating a high dependency of reference values on MRI protocol when compared to the literature. Furthermore, as presumed mean T1 and T2 values correlated in the same individual. Conclusions The T1 and T2 relaxation times depend on physiological factors and especially on MRI protocols. Therefore, reference values should be validated individually in every radiological institution before implementing mapping protocols in daily clinical practice. Correlation of mean T1 and T2 values in the same proband at both field strengths indicates intraindividual reproducibility.
引用
收藏
页码:143 / 155
页数:13
相关论文
共 50 条
  • [21] Age and sex corrected normal reference values of T1, T2 T2* and ECV in healthy subjects at 3T CMR
    Clotilde Roy
    Alisson Slimani
    Christophe de Meester
    Mihaela Amzulescu
    Agnès Pasquet
    David Vancraeynest
    Jean-Louis Vanoverschelde
    Anne-Catherine Pouleur
    Bernhard L. Gerber
    Journal of Cardiovascular Magnetic Resonance, 19
  • [22] Reference ranges of myocardial T1 and T2 mapping in healthy Chinese adults: a multicenter 3T cardiovascular magnetic resonance study
    Ziqian Xu
    Weihao Li
    Jiaqi Wang
    Fei Wang
    Bin Sun
    Shifeng Xiang
    Xiao Luo
    Yanfeng Meng
    Xiang Wang
    Ximing Wang
    Jianxun Song
    Min Zhang
    Dinghu Xu
    Xiaoyue Zhou
    Zhiguo Ju
    Jiayu Sun
    Yuchi Han
    Yucheng Chen
    Journal of Cardiovascular Magnetic Resonance, 25
  • [23] Reference ranges of myocardial T1 and T2 mapping in healthy Chinese adults: a multicenter 3T cardiovascular magnetic resonance study
    Xu, Ziqian
    Li, Weihao
    Wang, Jiaqi
    Wang, Fei
    Sun, Bin
    Xiang, Shifeng
    Luo, Xiao
    Meng, Yanfeng
    Wang, Xiang
    Wang, Ximing
    Song, Jianxun
    Zhang, Min
    Xu, Dinghu
    Zhou, Xiaoyue
    Ju, Zhiguo
    Sun, Jiayu
    Han, Yuchi
    Chen, Yucheng
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2023, 25 (01)
  • [24] Robust myocardial T2 and T2* mapping at 3T
    Arshad Zaman
    David M Higgins
    Marc Kouwenhoven
    Ananth Kidambi
    John P Greenwood
    Sven Plein
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [25] Myocardial T2*Imaging at 3T and 1.5T: A Pilot Study with Phantom and Normal Myocardium
    Chang, Suyon
    Park, Jinho
    Yang, Young-Joong
    Beck, Kyongmin Sarah
    Kim, Pan Ki
    Choi, Byoung Wook
    Jung, Jung Im
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2022, 9 (08)
  • [26] Dark-Blood T1 SAPPHIRE mapping gives cleaner myocardial signal at both 1.5T and 3T
    Augusto, Bicho J. A.
    Alfarih, M.
    Knott, K.
    Radenkovic, D.
    Chaturvedi, N.
    Hughes, A. D.
    Boubertakh, R.
    Moon, J. C.
    Weingartner, S.
    Captur, G.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2019, 20 : 325 - 325
  • [27] Myocardial T1 mapping at 3 T in healthy adults: reference values and influencing factors
    Lei Zhao
    Xiaohai Ma
    Zhanming Fan
    Tianjing Zhang
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [28] Myocardial T1 and T2 quantification and water-fat separation using cardiac MR fingerprinting with rosette trajectories at 3T and 1.5T
    Liu, Yuchi
    Hamilton, Jesse
    Eck, Brendan
    Griswold, Mark
    Seiberlich, Nicole
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (01) : 117 - 133
  • [29] Simultaneous Mapping of T1 and T2 Using Cardiac Magnetic Resonance Fingerprinting in a Cohort of Healthy Subjects at 1.5T
    Hamilton, Jesse I.
    Pahwa, Shivani
    Adedigba, Joseph
    Frankel, Samuel
    O'Connor, Gregory
    Thomas, Rahul
    Walker, Jonathan R.
    Killinc, Ozden
    Lo, Wei-Ching
    Batesole, Joshua
    Margevicius, Seunghee
    Griswold, Mark
    Rajagopalan, Sanjay
    Gulani, Vikas
    Seiberlich, Nicole
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2020, 52 (04) : 1044 - 1052
  • [30] DIFFERENCES IN QUANTITATIVE MYOCARDIAL PERFUSION MAPPING BY CMR AT 1.5T AND 3T
    Javed, Wasim
    Goh, Z.
    Shabi, M.
    Sharrack, N.
    Gorecka, M.
    Levelt, E.
    Xue, H.
    Dall'Armellina, E.
    Kellman, P.
    Greenwood, J. P.
    Plein, S.
    Swoboda, P. P.
    HEART, 2023, 109 (SUPPL_1) : A16 - A16