Initial Experience with the Impella Recover LP 2.5 Micro-Axial Pump in Patients Undergoing High-Risk Coronary Angioplasty

被引:0
|
作者
Thomopoulou, Sofia [1 ]
Manginas, Athanassios [1 ]
Cokkinos, Dennis V. [1 ]
机构
[1] Onassis Cardiac Surg Ctr, Dept Cardiol A, Athens 17674, Greece
关键词
Left ventricular assist device; high-risk percutaneous coronary revascularization;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: The Impella LP 2.5 device is a new percutaneous left ventricular assist device, an intravascular micro-axial blood pump designed for short term circulatory support in conditions characterized by profoundly reduced ventricular function. Percutaneous coronary intervention (PCI) is increasingly being used in patients who have severely compromised left ventricular contractility and complex coronary lesions, including multivessel disease. Methods: Three patients (pts) underwent elective PCI with the use of the Impella system. All were very poor candidates for surgery because of severe comorbidities, with mean logistic EuroSCORE 39.3%. Echocardiography was used to rule out anatomical contraindications before implantation of the device. All pts had previous myocardial infarctions and impaired left ventricular (LV) function with LV ejection fraction < 25-30%. We evaluated the effects of the pump on cardiac output, mean pulmonary wedge pressure and mean blood pressure, using right heart catheterization. We also assessed hemoglobin, cardiac enzymes (CK, CKMB and troponin), creatinine and NT-proBNP levels before and the day after the intervention. Results: The procedure was uncomplicated, without any acute, device-related adverse events during LV support. The Impella was used for a mean time of 9.3 hours (range 2 to 24 hours) and was removed immediately after the intervention in all but one patient. The device did not induce or increase aortic valve regurgitation. Two pts needed pharmacologic inotropic support during the procedure. Mean blood pressure increased in all 3 pts without pulmonary wedge pressure reduction, presumably due to a combination of pump function and PCI-induced ischemia. The mean drop in hemoglobin levels was 1.7 g/dl. The mean increase in creatinine levels due to contrast was 1 mg/dl. NT-proBNP showed a variable response. Two pts remained stable at follow up and one expired one month later due to worsening heart failure. Conclusions: The growing heart failure population and the benefit of revascularization in patients with severe LV dysfunction have led to an increase in the number of mechanically assisted percutaneous coronary interventions. Circulatory support with the Impella LP 2.5 pump during high risk PCI is feasible, but larger studies are required to demonstrate its efficacy in these severely compromised and vulnerable patients.
引用
收藏
页码:382 / 387
页数:6
相关论文
共 50 条
  • [21] One Pump For Two Hearts - A Single-center Experience With An Impella 5.5 Micro-axial Pump In A Peripartum Patient With Cardiogenic Shock
    Pillai, Ashwin
    Badr, Mai
    Mai, Xingchen
    Bell, Jennifer
    JOURNAL OF CARDIAC FAILURE, 2024, 30 (01) : 138 - 138
  • [22] Response by Flaherty to Letter Regarding Article, "Hemodynamic Support With a Micro-Axial Percutaneous Left Ventricular Assist Device (Impella) Protects Against Acute Kidney Injury in Patients Undergoing High-Risk Percutaneous Coronary Intervention"
    Flaherty, Michael P.
    CIRCULATION RESEARCH, 2017, 120 (11) : E52 - E53
  • [23] Left ventricular assistant device impella 2.5 usage for patients undergoing high-risk PCI
    Palacios, Igor F.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2012, 79 (07) : 1135 - 1137
  • [24] Left ventricular unloading and concomitant total cardiac output increase by the use of percutaneous impella recover LP 2.5 assist device during high-risk coronary intervention
    Valgimigli, M
    Steendijk, P
    Sianos, G
    Onderwater, E
    Serruys, PW
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2005, 65 (02) : 263 - 267
  • [25] Letter by Naranjo et al Regarding Article, "Hemodynamic Support With a Micro-Axial Percutaneous Left Ventricular Assist Device (Impella) Protects Against Acute Kidney Injury in Patients Undergoing High-Risk Percutaneous Coronary Intervention"
    Naranjo, Mario
    Rangaswami, Janani
    Witzke, Christian
    CIRCULATION RESEARCH, 2017, 120 (11) : E51 - E51
  • [26] PROTECT I:: A prospective feasibility trial investigating the use of the IMPELLA® RECOVER® LP 2.5 system in high risk PCI patients
    Neill, William O'
    Civitello, Andrew
    Collins, Michael
    Mauri, Laura
    Teirstein, Paul
    Benali, Karim
    AMERICAN JOURNAL OF CARDIOLOGY, 2007, 100 (8A): : 60L - 60L
  • [27] Supported High-Risk Percutaneous Coronary Intervention using the Impella LP2.5 device. The Europella Registry
    Sjauw, Krischan D.
    Hassager, Christian
    Danna, Paolo L.
    Konorza, Thomas
    Engstrom, Annemarie E.
    Minden, Hans-Heinrich
    Butter, Christian
    Machado, F. P.
    Pedrazzini, Giovanni P.
    Wagner, Daniel R.
    Kerber, Sebastian
    Schamberger, Rainer
    Schofer, Joachim
    Mathey, Detlef G.
    Erbel, Raimund
    Viecca, Maurizio
    Engstroem, Thomas
    Henriques, Jose P. S.
    AMERICAN JOURNAL OF CARDIOLOGY, 2008, 102 (8A): : 186I - 186I
  • [28] Supported High-Risk Percutaneous Coronary Intervention Using The Impella LP2.5 Device. The Europella Registry
    Sjauw, Krischan D.
    Hassager, Christian
    Donna, Paolo L.
    Konorza, Thomas
    Engstrom, Annemarie E.
    Minden, Hans-Heinrich
    Butter, Christian
    Machado, F. P.
    Pedrazzini, Giovanni
    Wagner, Daniel R.
    Wagner, Daniel R.
    Kerber, Sebastian
    Schamberger, Rainer
    Schofer, Joachim
    Mathey, Detlef G.
    Erbel, Raimund
    Viecca, Maurizio
    Engstrom, Thomas
    Henriques, Jose P.
    CIRCULATION, 2008, 118 (18) : S893 - S893
  • [29] Coronary and myocardial haemodynamic effects of Impella LV unloading in patients undergoing high-risk percutaneous coronary intervention
    Briceno, Natalia
    Ryan, Matthew
    O'Gallagher, Kevin
    Ellis, Howard
    Patterson, Tiffany
    Modi, Bhavik
    Rahman, Haseeb
    Clapp, Brian
    Pavlidis, Antonis
    Redwood, Simon
    Shah, Ajay
    Perera, Divaka
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (13) : B181 - B181
  • [30] Prophylactic use of intra-aortic balloon pump for high-risk percutaneous coronary intervention: will the Impella LP 2.5 device show superiority in a clinical randomized study?
    Syed, Asmir I.
    Karkar, Amit
    Torguson, Rebecca
    Li, Yanlin
    Ben-Dor, Itsik
    Collins, Sara D.
    Lemesle, Gilles
    Maluenda, Gabriel
    Xue, Zhenyi
    Scheinowitz, Mickey
    Kaneshige, Kimberly
    Satler, Lowell F.
    Kent, Kenneth M.
    Suddath, William O.
    Pichard, Augusto D.
    Lindsay, Joseph
    Waksman, Ron
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2010, 11 (02) : 91 - 97