Impact of CT attenuation correction by SPECT/CT in brain perfusion images

被引:24
|
作者
Ishii, Kazunari [1 ]
Hanaoka, Kohei [1 ]
Okada, Masahiro [1 ]
Kumano, Seishi [1 ]
Komeya, Yoshihiro [1 ]
Tsuchiya, Norio [1 ]
Hosono, Makoto [1 ]
Murakami, Takamichi [1 ]
机构
[1] Kinki Univ, Fac Med, Dept Radiol, Osaka 5898511, Japan
关键词
SPECT/CT; Brain perfusion; Attenuation correction; Chang's method; SCATTER CORRECTION; NONUNIFORM;
D O I
10.1007/s12149-011-0567-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to elucidate the regional differences between brain perfusion single photon emission computed tomography (SPECT) images reconstructed with a uniform attenuation correction using Chang's method (AC-Chang) and a non-uniform attenuation correction with CT using SPECT/CT (AC-CT). SPECT images of a phantom with and without head holder were obtained, and reconstructed images of AC-Chang and AC-CT were compared. Twenty-eight consecutive patients with brain disease examined by SPECT/CT brain perfusion imaging were selected, and images were reconstructed with AC-Chang and AC-CT. The AC-Chang and AC-CT reconstructed images were then compared by voxel-based analysis using three-dimensional stereotactic surface projections. Counts in the frontal area of the AC-Chang phantom image with head holder were higher than those in the posterior area. Counts in the frontal area of the AC-Chang clinical images were significantly higher than those in the AC-CT images, while the counts in the margin of the frontal lobe and posterior margin of the parietal, occipital cortices and cerebellum of the AC-Chang images were significantly lower. Relative frontal perfusion was 5.0% higher and relative cerebellar perfusion was 4.6% lower in the AC-Chang images relative to the AC-CT images, on average. We demonstrated the frontal dominant hyper-perfusion and parieto-occipital and cerebellar hypo-perfusion in brain SPECT images reconstructed with AC-Chang compared to those reconstructed with AC-CT. We suggest that to obtain an accurate attenuation-corrected brain perfusion SPECT image, attenuation correction by Chang's method is inadequate.
引用
收藏
页码:241 / 247
页数:7
相关论文
共 50 条
  • [21] Development of a brain perfusion SPECT attenuation correction method using synthetic CT images generated by MR images with a deep convolutional neural network
    Morisawa, Y.
    Uchiyama, Y.
    Takaki, A.
    Ito, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (SUPPL 1) : S214 - S215
  • [22] Attenuation correction of myocardial SPECT perfusion images with low-dose CT: Evaluation of the method by comparison with perfusion PET
    Fricke, E
    Fricke, H
    Weise, R
    Kammeier, A
    Hagedorn, R
    Lotz, N
    Lindner, O
    Tschoepe, D
    Burchert, W
    JOURNAL OF NUCLEAR MEDICINE, 2005, 46 (05) : 736 - 744
  • [23] Diagnostic implications of CZT SPECT and impact of CT attenuation correction
    Andrew Peters
    Jeevan Kumar
    Pravin V. Patil
    Journal of Nuclear Cardiology, 2019, 26 : 246 - 249
  • [24] Diagnostic implications of CZT SPECT and impact of CT attenuation correction
    Peters, Andrew
    Kumar, Jeevan
    Patil, Pravin V.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2019, 26 (01) : 246 - 249
  • [25] Quantification of the influence of misregistration between CT and SPECT images on the accuracy of CT-based attenuation correction of cardiac images in hybrid SPECT/CT systems
    Saleki, I.
    Bitarafan-Rajabi, A.
    Yaghobi, N.
    Falahi, B.
    Ay, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S518 - S518
  • [26] Quantitative Evaluation of the Effect of Attenuation Correction in SPECT Images with CT-Derived Attenuation
    Tavakoli, Meysam
    Naji, Maryam
    MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [27] Attenuation-correction of myocardial perfusion SPECT with CT adjusted registration. Comparison with non-attenuation-corrected images
    Philippe, Laurent L.
    Chetanneau, A.
    Havard, L.
    Hery-Morin, S.
    Lecomte, R.
    Pelissier, S.
    Raby, C.
    Roy, A.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2009, 11 (0B) : S6 - S6
  • [28] The impact of attenuation correction in SPECT/CT on quantitative parameters of myocardial perfusion in patients with intact coronary arteries
    Khachirova, E.
    Samoylenko, L.
    Shevchenko, O.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S562 - S562
  • [29] Single CT for attenuation correction of rest/stress cardiac SPECT perfusion imaging
    Wells, R. Glenn
    Trottier, Mikael
    Premaratne, Manuja
    Vanderwerf, Karen
    Ruddy, Terrence D.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2018, 25 (02) : 616 - 624
  • [30] Diagnostic impact of CT attenuation correction on CZT myocardial perfusion SPECT in patients with coronary artery disease compared to cardiac SPECT/CT hybrid imaging
    Fukushima, Y.
    Kumita, S.
    Hashimoto, H.
    Sugihara, Y.
    Iwata, K.
    Hamana, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S558 - S558