Dosimetry Methods of Fast Neutron Using the Semiconductor Diodes

被引:0
|
作者
Dizaji, H. Zaki [1 ,2 ]
Kakavand, T. [3 ]
Davani, F. Abbasi [4 ]
机构
[1] Zanjan Univ, Dept Phys, Fac Sci, Zanjan, Iran
[2] Imam Hossein Comprehens Univ, Dept Phys, Fac Sci, Tehran, Iran
[3] Imam Khomeini Int Univ, Dept Phys, Fac Sci, Qazvin, Iran
[4] Shahid Beheshti Univ, Dept Radiat Applicat, Tehran, Iran
关键词
ACTIVE PERSONAL DOSIMETERS; DETECTORS; GAAS;
D O I
10.1088/0256-307X/31/1/012901
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Semiconductor detectors based on a silicon pin diode are frequently used in the detection of different nuclear radiations. For the detection and dosimetry of fast neutrons, these silicon detectors are coupled with a fast neutron converter. Incident neutrons interact with the converter and produce charged particles that can deposit their energy in the detectors and produce a signal. In this study, three methods are introduced for fast neutron dosimetry by using the silicon detectors, which are: recoil proton spectroscopy, similarity of detector response function with conversion function, and a discriminator layer. Monte Carlo simulation is used to calculate the response of dosimetry systems based on these methods. In the different doses of an Am-241-Be neutron source, dosimetry responses are evaluated. The error values of measured data for dosimetry by these methods are in the range of 15-25%. We find fairly good agreement in the Am-241-Be neutron sources.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] FAST-NEUTRON DOSIMETRY USING F-CENTERS IN MGO
    RITZ, VH
    ATTIX, FH
    APPLIED PHYSICS LETTERS, 1973, 23 (03) : 166 - 168
  • [22] FAST-NEUTRON DOSIMETRY USING F-CENTERS IN MGO
    RITZ, VH
    ATTIX, FH
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1973, 18 (04): : 579 - 580
  • [23] Photon and fast neutron dosimetry using aluminium oxide thermoluminescence dosemeters
    Santos, J. P.
    Fernandes, A. C.
    Goncalves, I. C.
    Marques, J. G.
    Carvalho, A. F.
    Santos, L.
    Cardoso, J.
    Osvay, M.
    RADIATION PROTECTION DOSIMETRY, 2006, 120 (1-4) : 358 - 360
  • [24] Total Body Irradiation Using a Modified Standing Technique: In Vivo Dosimetry with Semiconductor Diodes
    Cecen, Yigit
    Sindir, Bora
    Aksu, M. Gamze
    Ozdemir, Beyza S.
    Korcum, Aylin F.
    Tuncel, Nina
    Yavuz, Melek N.
    UHOD-ULUSLARARASI HEMATOLOJI-ONKOLOJI DERGISI, 2013, 23 (01): : 43 - 48
  • [25] ADVANCED METHODS IN NEUTRON PERSONNEL DOSIMETRY
    BECKER, K
    KERNTECHNIK ISOTOPENTECHNIK UND CHEMIE, 1965, 7 (06): : 274 - &
  • [26] Reference dosimetry for fast neutron and proton therapy
    Jones, DTL
    RADIOCHIMICA ACTA, 2001, 89 (4-5) : 279 - 287
  • [27] ALTERNATIVE APPROACH TO FAST-NEUTRON DOSIMETRY
    VIRK, HS
    SINGH, RC
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 1994, 32 (06) : 526 - 527
  • [28] Thermoluminescence dosimetry in a fast neutron therapy beam
    Bhengu, KJ
    Langen, KM
    Symons, JE
    Jones, DTL
    RADIATION PHYSICS AND CHEMISTRY, 2004, 71 (3-4) : 981 - 982
  • [29] FAST-NEUTRON SCATTERING - A CORRECTION FOR DOSIMETRY
    CURE, JW
    HURST, GS
    NUCLEONICS, 1954, 12 (08): : 36 - 38
  • [30] DOSIMETRY OF HIGH FAST-NEUTRON FLUXES
    LOTZ, U
    PITT, E
    SCHARMANN, A
    ATOMKERNENERGIE-KERNTECHNIK, 1980, 36 (02): : 107 - 108