Titanium prosthesis or autologous incus for total ossicular reconstruction in the absence of the stapes suprastructure and presence of mobile footplate

被引:14
|
作者
Zakzouk, Abdulmajeed [1 ]
Bonmardion, Nicolas [1 ]
Bouchetemble, Pierre [1 ]
Lerosey, Yannick [1 ]
Marie, Jean-Paul [1 ]
机构
[1] Univ Hosp, Serv Otolaryngol, F-76000 Rouen, France
关键词
Ossiculoplasty; Autologous incus; Titanium prosthesis; Mobile footplate;
D O I
10.1007/s00405-014-3212-2
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
The purpose of this study was to compare the hearing results after total ossicular replacement with a titanium prosthesis or autologous incus in the absence of stapes suprastructure and presence of mobile footplate as a retrospective medical record review in a tertiary referral center setting. There were 49 patients who had total ossicular reconstruction (titanium prosthesis, 40 patients; autologous incus, 9 patients). Medical records were reviewed after total ossicular replacement. Air-bone gap at 1 and 2 years after surgery were determined with the 4-frequency average (0.5, 1, 2, and 4 kHz) and the American Academy of Otolaryngology-Head and Neck Surgery 4-frequency average (0.5, 1, 2, and 3 kHz). The number of patients who had air-bone gap < 20 dB was determined. For comparisons that were based on American Academy of Otolaryngology-Head and Neck Surgery 4-frequency average, mean air-bone gap at 2 years after surgery was significantly smaller for the titanium prosthesis (21 dB) than autologous incus group (31 dB; P a parts per thousand currency sign 0.03); the frequency of patients who had air-bone gap < 20 dB at 1 or 2 years after surgery was significantly greater for the titanium prosthesis (1 year, 40 %; 2 years, 56 %) than autologous incus group [1 year, 0 % (P a parts per thousand currency sign 0.03); 2 years, 0 % (P a parts per thousand currency sign 0.04)]. Titanium prosthesis ossiculoplasty gave better results than autologous incus in the absence of the stapes suprastructure and presence of a mobile footplate.
引用
收藏
页码:2653 / 2657
页数:5
相关论文
共 21 条
  • [21] Long-Term Hearing Results of Endoskeletal Ossicular Reconstruction in Chronic Ears Using Titanium Prostheses Having a Helical Coil: Part 1-Kraus K-Helix Crown, Incus to Stapes
    Kraus, Eric M.
    Russell, Gregory B.
    Allen, Sarah J.
    Pearson, Sarah A.
    OTOLOGY & NEUROTOLOGY, 2022, 43 (09) : 1056 - 1064