Effect of surface treatment on retention of glass-fiber endodontic posts

被引:135
|
作者
Balbosh, A [1 ]
Kern, M [1 ]
机构
[1] Univ Kiel, Sch Dent, Dept Prosthodont Propaedeut & Dent Mat, D-24105 Kiel, Germany
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2006年 / 95卷 / 03期
关键词
D O I
10.1016/j.prosdent.2006.01.006
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The effects of surface treatment on the retention of Prefabricated fiber-reinforced epoxy resin posts are not well understood because most studies measure retention shortly after cementation, without artificial aging. Purpose. The purpose of this study was to evaluate the effect of surface treatment on the retention of glass-fiber endodontic posts luted with resin cement and subjected to artificial aging. Material and methods. Thirty-two single-rooted teeth were selected, the coronal aspect of each tooth was removed, and the remaining root received endodontic therapy. Specimens were then divided into 4 groups (n=8). Post spaces were prepared to a depth of 10 turn by using ISO 90 rotary instruments. The tapered posts received I of 4 surface treatments: cleaning with alcohol (Alc), cleaning with alcohol and conditioning with ED-Primer material (Alc-ED), airborne-particle abrasion (Air), or airborne-particle abrasion and conditioning with ED-Primer material (Air-ED). All posts were lured with a composite resin luting agent (Panavia F) after conditioning the canal dentin with autopolymerizing dentin primer (ED-Primer) and without acid etching of the canal dentin. After cementation, the specimens were stored in water at 37 degrees C for 30 days and subjected to simulated aging conditions consisting of 7500 thermal cycles (5 degrees C/55 degrees C) and 300,000 mechanical loading cycles with 30 N. Retention (N) of the posts was measured with a universal testing machine with a crosshead speed of 2 mm/min. The data were analyzed using 1-way ANOVA and the Tukey HSD test (alpha=.05). The dislodged posts were also examined microscopically at X8 and X20 magnification to evaluate the mode of failure. Results. The mean retentive values (N) and SDs of the test groups were as follows: Alc, 375.9 +/- 85.0; Alc-ED, 421.2 +/- 46.8; Air, 534.8 +/- 65.8; and Air-ED, 555.8 +/- 86.9. Airborne-particle-abraded posts had significantly higher retention compared with nonabraded posts (P <.001). Treating the post's surface with ED-Primer material prior to cementation had no significant effect on retention. The failure mode was purely adhesive at the resin cement-post interface for all nonabraded posts. A mixed failure mode, adhesive at the resin cement-dentin interface, at the resin cement-post interface, and cohesive in the resin cement, was observed for airborne-particle-abraded posts. Conclusion. Treating the surface of the posts with ED-Primer material before cementation with Panavia F cement produced no significant improvement in the retention of the posts. Airborne-particle abrasion of the surface of the post significantly improved the retention.
引用
收藏
页码:218 / 223
页数:6
相关论文
共 50 条
  • [31] SESTON RETENTION BY WHATMAN GF/C GLASS-FIBER FILTERS
    HICKEL, W
    MARINE ECOLOGY PROGRESS SERIES, 1984, 16 (1-2) : 185 - 191
  • [32] Effect of calcium silicate-based endodontic sealer on the retention of fiber posts cemented at different time intervals
    Alsubait, Sara Abdulrahman
    SAUDI DENTAL JOURNAL, 2021, 33 (07) : 718 - 723
  • [33] Microhardness of composites in simulated root canals cured with light transmitting posts and glass-fiber reinforced composite posts
    Yoldas, O
    Alaçam, T
    JOURNAL OF ENDODONTICS, 2005, 31 (02) : 104 - 106
  • [34] Effect on Push-out Bond Strength of Glass-fiber Posts Functionalized with Polydopamine Using Different Adhesives
    Chen, Qian
    Cai, Qing
    Li, Yan
    Wei, Xu-Yi
    Huang, Zhi
    Wang, Xin-Zhi
    JOURNAL OF ADHESIVE DENTISTRY, 2014, 16 (02): : 177 - 184
  • [35] Surface treatments of a glass-fiber reinforced composite: Effect on the adhesion to a composite resin
    Cadore-Rodrigues, Ana C.
    Guilardi, Luis F.
    Wandscher, Vinicius F.
    Pereira, Gabriel K. R.
    Valandro, Luiz F.
    Rippe, Marilia P.
    JOURNAL OF PROSTHODONTIC RESEARCH, 2020, 64 (03) : 301 - 306
  • [36] Effect of photodynamic therapy on the mechanical properties and bond strength of glass-fiber posts to endodontically treated intraradicular dentin
    Strazzi Sahyon, Henrico Badaoui
    da Silva, Paloma Pereira
    de Oliveira, Murilo Silva
    Angelo Cintra, Luciano Tavares
    Gomes-Filho, Joao Eduardo
    dos Santos, Paulo Henrique
    Sivieri-Araujo, Gustavo
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (02):
  • [37] Adhesion strategy and early bond strengths of glass-fiber posts luted into root canals
    Faria-e-Silva, Andre Luis
    Melo Mendonca, Adriano Augusto
    Viana de Braganca Garcez, Rosa Maria
    de Oliveira, Aline do Silva
    Moreira, Andressa Goicochea
    de Moraes, Rafael Ratto
    BRAZILIAN ORAL RESEARCH, 2012, 26 (05): : 485 - 487
  • [38] MODELING SURFACE DEFORMATION OF GLASS-FIBER REINFORCED COMPOSITES
    KIA, HG
    JOURNAL OF COMPOSITE MATERIALS, 1986, 20 (04) : 335 - 346
  • [39] In vitro fracture resistance of zirconia, glass-fiber, and cast metal posts with different lengths
    Palepwad, Ashutosh B.
    Kulkarni, Rahul Shyamrao
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2020, 20 (02): : 202 - 207
  • [40] PROPERTIES OF GLASS-FIBER CEMENT - EFFECT OF FIBER LENGTH AND CONTENT
    ALI, MA
    MAJUMDAR, AJ
    SINGH, B
    JOURNAL OF MATERIALS SCIENCE, 1975, 10 (10) : 1732 - 1740