Implementation of a volumetric modulated arc therapy treatment planning solution for kidney and adrenal stereotactic body radiation therapy

被引:5
|
作者
Sonier, Marcus [1 ]
Chu, William [1 ,2 ]
Lalani, Nafisha [1 ]
Erler, Darby [1 ]
Cheung, Patrick [1 ,2 ]
Korol, Renee [1 ]
机构
[1] Sunnybrook Hlth Sci Ctr, Odette Canc Ctr, Toronto, ON, Canada
[2] Univ Toronto, Dept Radiat Oncol, Toronto, ON, Canada
关键词
VMAT; SBRT; RCC; Oligometastases; Treatment planning; Motion management; RADIOTHERAPY; CT;
D O I
10.1016/j.meddos.2016.09.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
To develop a volumetric modulated arc therapy (VMAT) treatment planning solution in the treatment of primary renal cell carcinoma and oligometastatic adrenal lesions with stereotactic body radiation therapy. Single-arc VMAT plans (n = 5) were compared with clinically delivered step-and-shoot intensity-modulated radiotherapy (IMRT) with planning target volume coverage normalized between techniques. Target volume conformity, organ-at-risk (OAR) dose, treatment time, and monitor units were compared. A VMAT planning solution, created from a combination of arc settings and optimization constraints, auto-generated treatment plans in a single optimization. The treatment planning solution was evaluated on 15 consecutive patients receiving kidney and adrenal stereotactic body radiation therapy. Treatment time was reduced from 13.0 +/- 2.6 to 4.0 +/- 0.9 minutes for IMRT and VMAT, respectively. The VMAT planning solution generated treatment plans with increased target homogeneity, improved 95% conformity index, and a reduced maximum point dose to nearby OARs but with increased intermediate dose to distant OARs. The conformity of the 95% isodose improved from 1.32 +/- 0.39 to 1.12 +/- 0.05 for IMRT and VMAT treatment plans, respectively. Evaluation of the planning solution showed clinically acceptable dose distributions for 13 of 15 cases with tight conformity of the prescription isodose to the planning target volume of 1.07 +/- 0.04, delivering minimal dose to OARs. The introduction of a stereotactic body radiation therapy VMAT treatment planning solution improves the efficiency of planning and delivery time, producing treatment plans of comparable or superior quality to IMRT in the case of primary renal cell carcinoma and oligometastatic adrenal lesions. (C) 2016 American Association of Medical Dosimetrists.
引用
收藏
页码:323 / 328
页数:6
相关论文
共 50 条
  • [1] A COMPARISON OF STEREOTACTIC BODY RADIOTHERAPY MODALITIES: VOLUMETRIC MODULATED ARC THERAPY VERSUS INTENSITY MODULATED RADIATION THERAPY IN TREATMENT OF KIDNEY CANCER
    Chaudhary, Simone
    Swaminath, Anand
    Lukka, Himansu
    Chow, Tom
    Vansantvoort, Jasmin
    RADIOTHERAPY AND ONCOLOGY, 2019, 139 : S63 - S63
  • [2] Volumetric Modulated Arc Therapy (VMAT) Treatment Planning for Thoracic Vertebral Metastases Using Stereotactic Body Radiation Therapy (SBRT)
    Mallory, M.
    Pokhrel, D.
    Badkul, R. K.
    Jiang, H.
    Wang, F.
    Lominska, C. E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E650 - E651
  • [3] Volumetric Modulated Arc Therapy for Stereotactic Body Radiation Therapy: Initial Clinical Experience
    Matuszak, M.
    Yan, D.
    Grills, I.
    Martinez, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S723 - S724
  • [4] Stereotactic Radiation Treatment Planning with Volumetric Modulated Arc Therapy (VMAT): Impact of Duodenal Sparing
    Herman, J. M.
    Kang, J.
    Tuli, R.
    Wolfgang, C.
    Pawlik, T. M.
    Tryggestad, E.
    Smith, K.
    DeWeese, T. L.
    Wong, J.
    Ford, E. C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S790 - S791
  • [5] A comparison of robustness of volumetric modulated arc therapy and dynamic conformal arc therapy for lung stereotactic body radiation therapy
    Teague, Kathlina M.
    Miller, Daniel C.
    Nyamwanda, Jacqueline A.
    Prichard, Hugh A.
    Kirk, Michael C.
    MEDICAL DOSIMETRY, 2022, 47 (01) : 110 - 110
  • [6] Treatment planning for volumetric modulated arc therapy
    Bedford, James L.
    MEDICAL PHYSICS, 2009, 36 (11) : 5128 - 5138
  • [7] TREATMENT PLANNING WITH VOLUMETRIC MODULATED ARC THERAPY FOR STEREOTACTIC BODY RADIOTHERAPY (SBRT) OF SPINAL/PARASPINAL TUMOURS
    Marchand, E. L.
    Sahgal, A.
    Millar, B. A.
    Publicover, J.
    Sharpe, M.
    Moseley, D.
    Letourneau, D.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S48 - S48
  • [8] Volumetric modulated arc therapy treatment planning of thoracic vertebral metastases using stereotactic body radiotherapy
    Mallory, Matthew
    Pokhrel, Damodar
    Badkul, Rajeev
    Jiang, Hongyu
    Lominska, Christopher
    Wang, Fen
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (02): : 54 - 61
  • [9] Efficient Treatment Delivery of Lung Stereotactic Body Radiation Therapy (SBRT) Using Volumetric Modulated Arc Therapy (VMAT)
    Comsa, D. C.
    Purdie, T. G.
    Chao, J.
    Moseley, D. J.
    MEDICAL PHYSICS, 2009, 36 (09) : 4320 - 4320
  • [10] Biological-based optimization and volumetric modulated arc therapy delivery for stereotactic body radiation therapy
    Diot, Quentin
    Kavanagh, Brian
    Timmerman, Robert
    Miften, Moyed
    MEDICAL PHYSICS, 2012, 39 (01) : 237 - 245