X-ray imaging with scintillator-sensitized hybrid organic photodetectors

被引:0
|
作者
Buechele, Patric [1 ,2 ,3 ]
Richter, Moses [4 ]
Tedde, Sandro F. [1 ]
Matt, Gebhard J. [4 ]
Ankah, Genesis N. [5 ]
Fischer, Rene [1 ,4 ]
Biele, Markus [1 ,4 ]
Metzger, Wilhelm [1 ]
Lilliu, Samuele [6 ]
Bikondoa, Oier [7 ,8 ]
Macdonald, J. Emyr [9 ]
Brabec, Christoph J. [4 ]
Kraus, Tobias [5 ]
Lemmer, Uli [2 ,3 ]
Schmidt, Oliver [1 ]
机构
[1] Siemens Healthcare GmbH, Ctr Technol, D-91058 Erlangen, Germany
[2] Karlsruhe Inst Technol, Light Technol Inst, D-76131 Karlsruhe, Germany
[3] Karlsruhe Inst Technol, Inst Microstruct Technol, D-76131 Karlsruhe, Germany
[4] Univ Erlangen Nurnberg, I MEET, D-91058 Erlangen, Germany
[5] INM Leibniz Inst New Mat, D-66123 Saarbrucken, Germany
[6] Masdar Inst Sci & Technol, Abu Dhabi 54224, U Arab Emirates
[7] ESRF European Synchrotron, XMaS, UK CRG Beamline, CS40220, F-38043 Grenoble 9, France
[8] Univ Warwick, Dept Phys, Coventry CV4 7AL, W Midlands, England
[9] Cardiff Univ, Sch Phys & Astron, Cardiff CF24 3AA, S Glam, Wales
关键词
SOLAR-CELLS; BULK HETEROJUNCTIONS; CURRENT TRANSIENTS; CHARGE-TRANSPORT; BLENDS; PHOTODIODES; POLYMER; CRYSTALLIZATION; PHOTOCONDUCTORS; PERFORMANCE;
D O I
10.1038/NPHOTON.2015.216
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Medical X-ray imaging requires cost-effective and high-resolution flat-panel detectors for the energy range between 20 and 120 keV. Solution-processed photodetectors provide the opportunity to fabricate detectors with a large active area at low cost. Here, we present a disruptive approach that improves the resolution of such detectors by incorporating terbium-doped gadolinium oxysulfide scintillator particles into an organic photodetector matrix. The X-ray induced light emission from the scintillators is absorbed within hundreds of nanometres, which is negligible compared with the pixel size. Hence, optical crosstalk, a limiting factor in the resolution of scintillator-based X-ray detectors, is minimized. The concept is validated with a 256 x 256 pixel detector with a resolution of 4.75 lp mm(-1) at a MTF = 0.2, significantly better than previous stacked scintillator-based flat-panel detectors. We achieved a resolution that proves the feasibility of solution-based detectors in medical applications. Time-resolved electrical characterization showed enhanced charge carrier mobility with increased scintillator filling, which is explained by morphological changes.
引用
收藏
页码:843 / 848
页数:6
相关论文
共 50 条
  • [41] Evaluation of the imaging performance of LSO powder scintillator for use in X-ray mammography
    Michal, C.
    David, S.
    Liaparinos, P.
    Valais, I.
    Nikolopoulos, D.
    Kalivas, N.
    Toutountzis, A.
    Cavouras, D.
    Kandarakis, I.
    Panayiotakis, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 558 - 561
  • [42] X-ray imaging performance of scintillator-filled silicon pore arrays
    Simon, Matthias
    Engel, Klaus Juergen
    Menser, Bernd
    Badel, Xavier
    Linnros, Jan
    MEDICAL PHYSICS, 2008, 35 (03) : 968 - 981
  • [43] Cerium Doping Double Perovskite Scintillator for Sensitive X-ray Detection and Imaging
    Wang, Zhilin
    Xu, Xieming
    Wang, Shuaihua
    Xu, Hui
    Xu, Weiwei
    Zeng, Qingyou
    Deng, Guoping
    Jiang, Yongzheng
    Wu, Shaofan
    CHEMISTRY-A EUROPEAN JOURNAL, 2021, 27 (35) : 9071 - 9076
  • [44] Scintillator Ink with Low-Temperature Thermoplastic for Micro X-Ray Imaging
    Wang, Tianchi
    Xu, Xuhui
    Yao, Shuyi
    Yu, Jing
    Yang, Zhi
    Qiu, Jianbei
    Yang, Yang
    Yu, Xue
    ADVANCED OPTICAL MATERIALS, 2024, 12 (10)
  • [45] Towards High-Resolution X-Ray Imaging Using a Structured Scintillator
    Hormozan, Yashar
    Yun, Sang-Ho
    Svenonius, Olof
    Linnros, Jan
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (01) : 19 - 23
  • [46] High-stability double perovskite scintillator for flexible X-ray imaging
    Li, Jingyu
    Hu, Qingsong
    Xiao, Jiawen
    Yan, Zheng-Guang
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2024, 671 : 725 - 731
  • [47] Eu2+-doped oxyfluoride glass scintillator for X-ray imaging
    Zou, Jiahao
    Li, Lianjie
    Chen, Junyu
    Fang, Xianfeng
    Qiao, Xvsheng
    Li, Hongjun
    Guo, Hai
    JOURNAL OF ALLOYS AND COMPOUNDS, 2025, 1020
  • [48] High-spatial-resolution X-ray Imaging by Scintillator in Silicon Collimator
    Tabata, Kento
    Ohtake, Ryota
    Aoki, Toru
    SENSORS AND MATERIALS, 2020, 32 (12) : 4037 - 4045
  • [49] Environment-friendly and highly efficiency organic antimony halide scintillator for light emitting diode and X-ray imaging
    Wang, Yijia
    Cao, Sijun
    Lai, Jun'an
    An, Kang
    Wu, Daofu
    Chen, Jinquan
    Mu, Haimen
    Wang, Zixian
    Guo, Linfeng
    He, Peng
    Tang, Xiaosheng
    Journal of Alloys and Compounds, 2025, 1024
  • [50] Organic and Inorganic Metal Halide Tandem Scintillator for Dual-Energy Flat-Panel X-ray Imaging
    Su, Yirong
    Ran, Peng
    Hui, Juan
    Ma, Wenbo
    Chen, Zeng
    Zhu, Haiming
    Yang, Yang Michael
    JOURNAL OF PHYSICAL CHEMISTRY LETTERS, 2023, 14 (26): : 6179 - 6186