Simulation of Novel Air-Source Heat Pump with Two-Stage Compression and Economizing for Cold Climate Field Tests

被引:0
|
作者
Caskey, Stephen L. [1 ]
Kultgen, Derek [1 ]
Menzi, Tobias [2 ]
Groll, Eckhard A. [1 ]
Hutzel, William J. [1 ]
Bertsch, Stefan S. [2 ]
机构
[1] Purdue Univ, Dept Mech Engn, W Lafayette, IN 47907 USA
[2] Interstate Univ Appl Sci Technol NTB, Dept Mech Engn, Buchs, Switzerland
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents simulation results of a modified air-source heat pump, which is optimized for cold climates and is to be field tested in Army barracks at Camp Atterbury, Indiana. The heat pump is designed to provide similar to 65,000 Btu/hr (19 kW) of heat at an ambient temperature of -4 degrees F (-20 degrees C) while achieving a heating COP that is approximately 45% of the seasonal Carnot heating COP. The heating requirements were calculated using a building load simulation tool, eQUEST. It is intended that the heat pump meets 100% of the building load throughout the year. The major modification from conventional air-source heat pumps is the introduction of two-stage compression with a closed economizing loop where two-phase refrigerant is injected between the compression stages. Components were selected based on their commercial availability in an attempt to aid the commercialization potential of the entire system for a potential Department of Defense implementation. Using the system simulation at different ambient temperatures and compressor configurations, the heat pump components were selected. The high-side compressor is to be a large displacement, variable-speed scroll compressor while the low-side compressor is to be a large displacement, fixed-speed, tandem scroll compressor. The results show that the selected configuration will yield a heat output of 57,938 Btu/hr (16.98 kW) at the design ambient temperature achieving a heating COP of 2.38 and a 2nd law efficiency of 44%.
引用
收藏
页码:354 / 361
页数:8
相关论文
共 50 条
  • [21] Experimental study and exergy analysis of electric vehicle single-stage compression secondary throttling CO 2 air-source heat pump system in cold climate
    Wang, Fengxian
    Wu, Weidong
    Wang, Rujin
    Chen, Lang
    Zhang, Hua
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2024, 164 : 75 - 85
  • [22] Energy consumption simulation and analysis of the two-stage centrifugal vapor-compression water source heat pump
    Jin, Quan
    Shu, Haiwen
    Lin Duanmu
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 152 - 159
  • [23] Intermediate pressure optimization for two-stage air-source heat pump with flash tank cycle vapor injection via extremum seeking
    Wang, Wenyi
    Li, Yaoyu
    APPLIED ENERGY, 2019, 238 : 612 - 626
  • [24] Performance study of a quasi-two-stage compression air-source heat pump system with an economizer coupled phase change accumulator
    Li, Yong
    Liu, Shihao
    Zhao, Yufei
    Zhang, Yingchun
    Feng, Biao
    Ma, Suxia
    ENERGY AND BUILDINGS, 2024, 317
  • [25] Simulation analysis of a novel no-frost air-source heat pump with integrated liquid desiccant dehumidification and compression-assisted regeneration
    Su, Wei
    Li, Weihao
    Zhang, Xiaosong
    ENERGY CONVERSION AND MANAGEMENT, 2017, 148 : 1157 - 1169
  • [26] Transient simulation of air-source heat pump during the reverse cycle defrost
    Liu, ZQ
    Tang, GF
    Zhao, FY
    CRYOGENICS AND REFRIGERATION - PROCEEDINGS OF ICCR'2003, 2003, : 695 - 698
  • [27] Dynamic simulation of an air-source heat pump water heater using novel modified evaporator model
    Chen, Jiaheng
    Yu, Jianlin
    APPLIED THERMAL ENGINEERING, 2018, 144 : 469 - 478
  • [28] An air-source hybrid absorption-compression heat pump with large temperature lift
    Gao, J. T.
    Xu, Z. Y.
    Wang, R. Z.
    APPLIED ENERGY, 2021, 291
  • [29] Development of the high-efficiency heat pump - Two-stage compression system for the cold area
    Yamamura, S.
    Zhong, M.
    CRYOGENICS AND REFRIGERATION, PROCEEDINGS, 2008, : 52 - 58
  • [30] Oil flooded compression cycle enhancement for two-stage heat pump in cold climate region: System design and theoretical analysis
    Luo, Baojun