Simulation of Novel Air-Source Heat Pump with Two-Stage Compression and Economizing for Cold Climate Field Tests

被引:0
|
作者
Caskey, Stephen L. [1 ]
Kultgen, Derek [1 ]
Menzi, Tobias [2 ]
Groll, Eckhard A. [1 ]
Hutzel, William J. [1 ]
Bertsch, Stefan S. [2 ]
机构
[1] Purdue Univ, Dept Mech Engn, W Lafayette, IN 47907 USA
[2] Interstate Univ Appl Sci Technol NTB, Dept Mech Engn, Buchs, Switzerland
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents simulation results of a modified air-source heat pump, which is optimized for cold climates and is to be field tested in Army barracks at Camp Atterbury, Indiana. The heat pump is designed to provide similar to 65,000 Btu/hr (19 kW) of heat at an ambient temperature of -4 degrees F (-20 degrees C) while achieving a heating COP that is approximately 45% of the seasonal Carnot heating COP. The heating requirements were calculated using a building load simulation tool, eQUEST. It is intended that the heat pump meets 100% of the building load throughout the year. The major modification from conventional air-source heat pumps is the introduction of two-stage compression with a closed economizing loop where two-phase refrigerant is injected between the compression stages. Components were selected based on their commercial availability in an attempt to aid the commercialization potential of the entire system for a potential Department of Defense implementation. Using the system simulation at different ambient temperatures and compressor configurations, the heat pump components were selected. The high-side compressor is to be a large displacement, variable-speed scroll compressor while the low-side compressor is to be a large displacement, fixed-speed, tandem scroll compressor. The results show that the selected configuration will yield a heat output of 57,938 Btu/hr (16.98 kW) at the design ambient temperature achieving a heating COP of 2.38 and a 2nd law efficiency of 44%.
引用
收藏
页码:354 / 361
页数:8
相关论文
共 50 条
  • [1] Experiment and simulation of two-stage compression air-source heat pump water heater
    Wu, W. B.
    Jin, S. M.
    CRYOGENICS AND REFRIGERATION, PROCEEDINGS, 2008, : 770 - 774
  • [2] Heating performance of a novel two-stage evaporator air-source heat-pump for drying applications
    Du, Anran
    Long, Jibo
    DRYING TECHNOLOGY, 2022, 40 (07) : 1356 - 1368
  • [3] A novel two-stage compression air-source heat pump cycle combining space heating, cooling, and domestic hot water production
    Liu, Jian
    Zhou, Lu
    Cheng, Jianhong
    Lin, Zhang
    Zhang, Xiaosong
    ENERGY AND BUILDINGS, 2023, 285
  • [4] Improving cold climate air-source heat pump performance with refrigerant mixtures
    Hakkaki-Fard, Ali
    Aidoun, Zine
    Ouzzane, Mohamed
    APPLIED THERMAL ENGINEERING, 2015, 78 : 695 - 703
  • [5] Modeling and optimization of two-stage compression heat pump system for cold climate applications
    Qiu, Kuanrong
    Thomas, Martin
    JOURNAL OF BUILDING ENGINEERING, 2024, 82
  • [6] Two-stage air-source heat pump for residential heating and cooling applications in northern US climates
    Bertsch, Stefan S.
    Groll, Eckhard A.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (07): : 1282 - 1292
  • [7] STUDY ON QUASI TWO-STAGE COMPRESSION CYCLE CHARACTERISTICS OF THE WATER HEATER OF THE AIR SOURCE HEAT PUMP IN COLD AREA
    LI, Haijun
    Su, Zhiyong
    Niu, Huawei
    Zhai, Junjie
    Kou, Jingkang
    Wang, Fang
    Cai, Xia
    Zhang, Qingge
    Wang, Shihao
    THERMAL SCIENCE, 2022, 26 (3B): : 2645 - 2651
  • [8] Energy Use and Greenhouse Gas Emissions of Air-Source Heat Pump and Innovative Ground-Source Air Heat Pump in a Cold Climate
    Mattinen, Maija K.
    Nissinen, Ari
    Hyysalo, Sampsa
    Juntunen, Jouni K.
    JOURNAL OF INDUSTRIAL ECOLOGY, 2015, 19 (01) : 61 - 70
  • [9] Performance of two-stage variable capacity air source heat pump: Field performance results and TRNSYS simulation
    Safa, Amir A.
    Fung, Alan S.
    Kumar, Rakesh
    ENERGY AND BUILDINGS, 2015, 94 : 80 - 90
  • [10] Experimental investigation of air-source heat pump for cold regions
    Ma, GY
    Chai, QH
    Jiang, Y
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2003, 26 (01): : 12 - 18