Determination of rimonabant in human plasma and hair by liquid chromatography-mass spectrometry

被引:10
|
作者
Delyle, Stanislas Grassin [1 ,2 ]
Abe, Emuri [1 ]
Devillier, Philippe [2 ]
Alvarez, Jean Claude [1 ]
机构
[1] Univ Hosp Raymond Poincare, AP HP, Lab Pharmacol Toxicol, F-92380 Carches, France
[2] Hop Foch, UPRES EA 220, Pharmacol Lab, F-92151 Suresnes, France
关键词
rimonabant; liquid chromatography; mass spectrometry; human plasma; human hair; cannabinoid antagonist;
D O I
10.1016/j.jchromb.2008.07.041
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Rimonabant is the first therapeutically relevant cannabinoid antagonist, licensed in Europe for treatment of obesity when a risk factor is associated. The objective of this study was to develop and validate a method for measurement of rimonabant in human plasma and hair using liquid chromatography coupled to mass spectrometry (LC-MS/MS). Rimonabant and AM-251 (internal standard) were extracted from 50 mu L of plasma or 10 mg of hair using diethylether. Chromatography was performed on a 150 mm x 2.1 mm 08 column using a mobile phase constituted of formate buffer/acetonitrile. Rimonabant was ionized by electrospray in positive mode, followed by detection with mass spectrometry. Data were collected either in full-scan MS or in full-scan MS/MS mode, selecting the ion m/z 463.1 for rimonabant and m/z 555.1 for IS. The most intense product ion of rimonabant (m/z 380.9) and IS (m/z 472.8) were used for quantification. Calibration curves covered a range from 2.5 (lower limit of quantification) to 1000.0 ng/ml. (upper limit of quantification) in plasma and from 2.5 to 1000.0 pg/mg in hair. Validation results demonstrated that rimonabant could be accurately and precisely quantified in both matrixes: accuracy and precision were within 85-115% and within 15% of standard deviation, respectively. Stability Studies in plasma showed that rimonabant was stable during the assay procedure, but a 30% decrease was observed for one concentration after 3 weeks at -20 C. This simple and robust LC-MS/MS method can be used for measuring rimonabant concentrations in human plasma and hair either in clinical or in forensic toxicology. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:115 / 120
页数:6
相关论文
共 50 条
  • [21] Comparison of liquid chromatography with fluorescence detection to liquid chromatography-mass spectrometry for the determination of fluoxetine and norfluoxetine in human plasma
    Kovacevic, I
    Miljkovic, B
    Jovanovic, D
    Prostran, M
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 830 (02): : 372 - 376
  • [22] Determination of phloroglucinol in human plasma by high-performance liquid chromatography-mass spectrometry
    Kim, H
    Roh, H
    Lee, H
    Chung, S
    Choi, S
    Lee, K
    Han, S
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 792 (02): : 307 - 312
  • [23] Analysis of Amlodipine in human plasma by liquid chromatography-mass spectrometry
    Feng, Y
    Zhang, L
    Shen, Z
    Pan, FY
    Zhang, ZX
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2002, 40 (01) : 49 - 53
  • [24] QUANTIFICATION OF CILNIDIPINE IN HUMAN PLASMA BY LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY
    Lee, Kyeong-Ryoon
    Chae, Yoon-Jee
    Lee, Jong-Hwa
    Kim, Dae-Duk
    Chong, Saeho
    Shim, Chang-Koo
    Chung, Suk-Jae
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2012, 35 (1-4) : 308 - 320
  • [25] Gas chromatography-mass spectrometry determination of matrine in human plasma
    Sit, DST
    Gao, GH
    Law, FCP
    Li, PCH
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 808 (02): : 209 - 214
  • [26] Determination of tizanidine in human plasma by gas chromatography-mass spectrometry
    Lee, J
    Seo, JH
    Kim, DH
    [J]. ANALYST, 2002, 127 (07) : 917 - 920
  • [27] Determination of hair nicotine by gas chromatography-mass spectrometry
    Man, Che Nin
    Ismail, Syazwani
    Harn, Gam Lay
    Lajis, Razak
    Awang, Rahmat
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (03): : 339 - 342
  • [28] Liquid Chromatography-Mass Spectrometry Determination of Cetrizine Hydrochloride in Rabbit Plasma
    Chandrasekar, M. J. N.
    Chandrasekar, A. R.
    Krishnaraj, K.
    Muralidharan, S.
    Rajan, S.
    Suresh, B.
    [J]. ASIAN JOURNAL OF CHEMISTRY, 2009, 21 (08) : 5821 - 5828
  • [29] Quantitative determination of sauchinone in rat plasma by liquid chromatography-mass spectrometry
    Xu, Chun-lei
    Chen, Jian-wei
    Ju, Wen-zheng
    Liu, Shi-jia
    Chen, Yong
    Chen, Zhi-peng
    Xue, Ping
    Chen, Hong-jiang
    Li, Xiang
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (10) : 1210 - 1214
  • [30] Quantitative determination of daumone in rat plasma by liquid chromatography-mass spectrometry
    Noh, Keumhan
    Park, Jung Hyun
    Park, Jong Hee
    Kim, Minkyu
    Jung, Mankil
    Ha, Hunjoo
    Kwon, Kwang-il
    Lee, Hwa Jeong
    Kang, Wonku
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 56 (01) : 114 - 117