Validation of a Clinical PET Scanner Using Monte Carlo Simulation Code: MCNP5

被引:0
|
作者
Musarudin, Marianie [1 ]
Saripan, M. Iqbal [1 ]
Mashohor, Syamsiah [1 ]
Saad, Wira Hidayat Mohd [1 ]
Hashim, Suhairul [2 ]
Nordin, Abdul Jalil [3 ]
机构
[1] Univ Putra Malaysia, Fac Engn, Serdang 43400, Malaysia
[2] Univ Teknol Malaysia, Fac Sci, Skudai, Johor, Malaysia
[3] Univ Putra Malaysia, Ctr Diagnost Nucl Imaging, Serdang 43400, Malaysia
关键词
validation; Monte Carlo; PET; WIRE-MESH COLLIMATOR; ATTENUATION CORRECTION; SPATIAL-RESOLUTION; BLOCK DETECTORS; PERFORMANCE; INSTRUMENTATION; DESIGN;
D O I
10.1109/EUROSIM.2013.16
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
This paper presents a realistic PET scanner simulation using Monte Carlo code, version MCNP5. The objective of our study was to verify the code used for this simulation by comparing the results obtained from the simulation with those obtained from the measurement did on a real PET scanner. This study will provide a basic benchmark for our further study on PET imaging. We modeled the scanner based on the physical specification of Siemens Biograph TruePoint PET scanner. We recorded the generated list-mode data which contains all the information needed to model the PET processes for instance coincidence photon detection. To account for the statistical fluctuations occur in the detector and photomultiplier tube, a Gaussian energy blurring model was applied to the energy deposited in the detector. The scatter and attenuation correction to correct the effect of scattered and attenuated events also took into account in this study. All of these post-simulation processes were done using a program developed using matlab. To validate the simulation, the simulated and measured energy and spatial resolution were compared. We have successfully modeled a PET system based on MCNP5. We also verified that this simulation result in a good agreement data with the real imaging.
引用
收藏
页码:36 / 41
页数:6
相关论文
共 50 条
  • [21] Development and Validation of a Monte Carlo Simulation Workflow for a Total-Body PET Scanner
    Pommranz, C.
    Elmoujarkach, E.
    Cabello, J.
    Lan, W.
    Rafecas, M.
    Mannheim, J.
    Linder, P.
    Santangelo, A.
    la Fougere, C.
    Pichler, B.
    Schmidt, F.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S690 - S691
  • [22] Image enhancement using MCNP5 code and MATLAB in neutron radiography
    Tharwat, Montaser
    Mohamed, Nader
    Mongy, T.
    APPLIED RADIATION AND ISOTOPES, 2014, 89 : 30 - 36
  • [23] MCNP5 Monte Carlo simulation of amorphous silicon EPID dosimetry from MLC radiation therapy treatment beams
    Juste, B.
    Miro, R.
    Morera, D.
    Diez, S.
    Campayo, J. M.
    Verdu, G.
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 5786 - 5789
  • [24] Benchmarking a Monte Carlo simulation code on a prototype LSO scanner
    Conti, M
    Casey, ME
    Eriksson, L
    Eriksson, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) : 644 - 648
  • [25] Benchmarking a Monte Carlo simulation code on a prototype LSO scanner
    Conti, M
    Casey, ME
    Eriksson, L
    Eriksson, M
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1277 - 1281
  • [26] Uncertainty Analysis in the Simulation of X-ray Spectra in the Diagnostic Range using the MCNP5 code
    Gallardo, S.
    Querol, A.
    Rodenas, J.
    Verdu, G.
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 389 - 392
  • [27] Extensions of the MCNP5 and TRIPOLI4 Monte Carlo Codes for Transient Reactor Analysis
    Hoogenboom, J. Eduard
    Sjenitzer, Bart L.
    SNA + MC 2013 - JOINT INTERNATIONAL CONFERENCE ON SUPERCOMPUTING IN NUCLEAR APPLICATIONS + MONTE CARLO, 2014,
  • [28] MTR benchmark static calculations with MCNP5 code
    Bousbia-Salah, Anis
    Benkharfia, Hocine
    Kriangehaiporn, Nateekoool
    Petruzzi, Alessandro
    D'Auria, Francesco
    Ghazi, Nidal
    ANNALS OF NUCLEAR ENERGY, 2008, 35 (05) : 845 - 855
  • [29] Design of light multi-layered shields for use in diagnostic radiology and nuclear medicine via MCNP5 monte carlo code
    Zehtabian, Mehdi
    Piruzan, Elham
    Molaiemanesh, Zahra
    Sina, Sedigheh
    Iranian Journal of Medical Physics, 2015, 12 (03) : 223 - 229
  • [30] Design of a Monte Carlo model based on dual-source computed tomography (DSCT) scanners for dose and image quality assessment using the Monte Carlo N-Particle (MCNP5) code
    Chantzi, Stefania
    Papanastasiou, Emmanouil
    Athanasopoulou, Christina
    Molyvda-Athanasopoulou, Elisavet
    Bamidis, Panagiotis
    Siountas, Anastasios
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2020, 26 (01): : 11 - 20