Elliptically polarized coherent anti-Stokes Raman scattering microscopy

被引:20
|
作者
Lu, Fake [1 ]
Zheng, Wei [1 ]
Huang, Zhiwei [1 ]
机构
[1] Natl Univ Singapore, Fac Engn, Dept Bioengn, Bioimaging Lab, Singapore 117576, Singapore
基金
英国医学研究理事会;
关键词
D O I
10.1364/OL.33.002842
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We report an approach to coherent anti-Stokes Raman scattering (CARS) microscopy that significantly suppresses the nonresonant background for high-contrast vibrational imaging. We employ an elliptically polarized pump field with an aspect ratio of 1: root 3 of the ellipse combined with a linearly polarized Stokes field for elliptically polarized CARS (EP-CARS) microscopy. The EP-CARS technique yields a 6-7-fold improvement in signal-to-background ratios compared with normal CARS, while providing an approximately 1.25-fold improvement in resonant CARS signal compared with normal polarization-sensitive CARS microscopy. We demonstrate this technique by imaging 1.5 mu m polystyrene beads in water and lipid droplets in unstained fibroblast cells. (C) 2008 Optical Society of America
引用
收藏
页码:2842 / 2844
页数:3
相关论文
共 50 条
  • [41] Coherent anti-Stokes Raman scattering microscopy: Instrumentation, theory, and applications
    Cheng, JX
    Xie, XS
    JOURNAL OF PHYSICAL CHEMISTRY B, 2004, 108 (03): : 827 - 840
  • [42] Fourier-transform coherent anti-Stokes Raman scattering microscopy
    Ogilvie, JP
    Beaurepaire, E
    Alexandrou, A
    Joffre, M
    OPTICS LETTERS, 2006, 31 (04) : 480 - 482
  • [43] Highly efficient coherent anti-Stokes Raman scattering (CARS)-microscopy
    Hellerer, T
    Enejder, AMK
    Burkacky, O
    Zumbusch, A
    MULTIPHOTON MICROSCOPY IN THE BIOMEDICAL SCIENCES IV, 2004, 5323 : 223 - 229
  • [44] Interferometric switching of coherent anti-Stokes Raman scattering signals in microscopy
    Nikolaenko, Alexei
    Krishnamachari, Vishnu Vardhan
    Potma, Eric Olaf
    PHYSICAL REVIEW A, 2009, 79 (01):
  • [45] Vibrational imaging coherent anti-Stokes Raman scattering (CARS) microscopy
    Djaker, N
    Lenne, PF
    Rigneault, H
    FEMTOSECOND LASER APPLICATIONS IN BIOLOGY, 2004, 5463 : 133 - 139
  • [46] Refractive effects in coherent anti-Stokes Raman scattering (CARS) microscopy
    不详
    EUROPEAN BIOPHYSICS JOURNAL WITH BIOPHYSICS LETTERS, 2005, 34 (06): : 816 - 816
  • [47] Live cell CARS (Coherent Anti-Stokes Raman Scattering) microscopy
    Zumbusch, A
    Hellerer, T
    BIOPHYSICAL JOURNAL, 2001, 80 (01) : 164A - 164A
  • [48] Design of supercontinuum source for coherent anti-Stokes Raman scattering microscopy
    Zhang H.
    Chang S.-J.
    Zhang Y.-X.
    Zhao X.-T.
    Optoelectronics Letters, 2008, 4 (02) : 103 - 105
  • [49] STOKES AND ANTI-STOKES COHERENT RAMAN-SCATTERING
    CHANDRA, S
    COMPAAN, AD
    WIENERAVNEAR, E
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1977, 22 (03): : 315 - 315
  • [50] Adaptive optics applied to coherent anti-Stokes Raman scattering microscopy
    Girkin, John M.
    Poland, Simon P.
    Wright, Amanda J.
    Freudiger, Christian
    Evans, Conor L.
    Xie, X. Sunney
    MULTIPHOTON MICROSCOPY IN THE BIOMEDICAL SCIENCES VIII, 2008, 6860