Fiber-optic Fourier-domain common-path OCT

被引:34
|
作者
Liu, Xuan [1 ]
Li, Xiaolu [1 ]
Kim, Do-Hyun [2 ]
Ilev, Ilko [2 ]
Kang, Jin U. [1 ]
机构
[1] Johns Hopkins Univ, Dept Elect & Comp Engn, Baltimore, MD 21218 USA
[2] US FDA, Ctr Devices & Radiol Hlth, Silver Spring, MD 20993 USA
关键词
D O I
10.3788/COL20080612.0899
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We experimentally and theoretically investigated the performance of a fiber-optic based Fourier-domain common-path optical coherence tomography (OCT). The fiber-optic common-path OCT operated at the 840-nm center wavelength. The resolution of the system was 8.8 mu m (in air) and the working depth using a bare fiber probe was approximately 1.5 mm. The signal-to-noise ratio (SNR) of the system was analyzed. OCT images obtained by the system were also presented.
引用
收藏
页码:899 / 901
页数:3
相关论文
共 50 条
  • [41] Spectrally encoded common-path fiber-optic-based parallel optical coherence tomography
    Lee, Kye-Sung
    Hur, Hwan
    Sung, Ha-Young
    Kim, I. Jong
    Kim, Geon-Hee
    OPTICS LETTERS, 2016, 41 (18) : 4241 - 4244
  • [42] Minimally-invasive common-path OCT system for neurosurgery applications
    Evans, Gary
    Gandar, Jerome
    Thiele, Simon
    Segar, David j.
    Cabara, Yoseline rosales
    Lapinski, Matthew
    Gantar, Ivana
    Campiche, Thierry
    Brana, Corinne
    Gora, Michalina j.
    Scholler, Jules
    BIOMEDICAL OPTICS EXPRESS, 2025, 16 (02): : 872 - 882
  • [43] Automatic online spectral calibration of Fourier-domain OCT for robotic surgery
    Liu, Xuan
    Balicki, Marcin
    Taylor, Russell H.
    Kang, Jin U.
    ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC SYSTEMS IX, 2011, 7890
  • [44] Use of Intraoperative Fourier-Domain Anterior Segment OCT During DSAEK
    Bosch, M. M.
    Kaufmann, C.
    Menke, M. N.
    Watson, S. L.
    Knecht, P. B.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [45] Fourier-Domain OCT in Multiple Sclerosis Patients: Reproducibility and Ability to Detect Retinal Nerve Fiber Layer Atrophy
    Garcia-Martin, Elena
    Pueyo, Victoria
    Pinilla, Isabel
    Ara, Jose-Ramon
    Martin, Jesus
    Fernandez, Javier
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (07) : 4124 - 4131
  • [46] Use of Fourier-domain OCT to detect retinal nerve fiber layer degeneration in Parkinson’s disease patients
    M Satue
    E Garcia-Martin
    I Fuertes
    S Otin
    R Alarcia
    R Herrero
    M P Bambo
    L E Pablo
    F J Fernandez
    Eye, 2013, 27 : 507 - 514
  • [47] Extending the effective imaging range of Fourier-domain optical coherence tomography using a fiber optic switch
    Wang, Hui
    Pan, Yinsheng
    Rollins, Andrew M.
    OPTICS LETTERS, 2008, 33 (22) : 2632 - 2634
  • [48] Use of Fourier-domain OCT to detect retinal nerve fiber layer degeneration in Parkinson's disease patients
    Satue, M.
    Garcia-Martin, E.
    Fuertes, I.
    Otin, S.
    Alarcia, R.
    Herrero, R.
    Bambo, M. P.
    Pablo, L. E.
    Fernandez, F. J.
    EYE, 2013, 27 (04) : 507 - 514
  • [49] Polarization-sensitive OCT using a single-mode fiber-based common-path probe
    Golde, Jonas
    Walther, Julia
    Li, Jiawen
    McLaughlin, Robert A.
    Koch, Edmund
    OPTICAL COHERENCE IMAGING TECHNIQUES AND IMAGING IN SCATTERING MEDIA IV, 2021, 11924
  • [50] Monte Carlo simulation of Fourier-domain OCT in multi-layered media
    School of Precision Instrument and Opto-Electronics Engineering, Tianjin University, Tianjin 300072, China
    不详
    Guangxue Jingmi Gongcheng, 2008, 7 (1285-1294):